Overview: The VLT® Advanced Active Filter AAF 006 by Danfoss is designed for harmonic mitigation in both central and decentralized systems. It can be used for individual VLT® drives or as a stand-alone solution to compensate for multiple loads simultaneously, ensuring optimal harmonic suppression and improved energy utilization.
Specifications: The filter operates within a voltage range of 380 – 480 V AC at 50 – 60 Hz and supports current ranges of 190 A, 250 A, 310 A, and 400 A. Up to four units can be paralleled for higher power requirements. It is available in enclosure degrees IP 21/NEMA Type 1 and IP 54/NEMA Type 12.
Features and Benefits: The filter is reliable, with a low failure rate and innovative cooling concepts that prolong the electronics' lifetime. It is user-friendly, offering modular design and high customization, which saves on commissioning and operating costs. Energy-saving features include high efficiency, sleep mode, and power factor correction.
Options: Available options include RFI filters, disconnects, fuses, and mains shielding. The VLT® MCT 10 Setup Software and VLT® MCT 31 Harmonics Calculation Software provide advanced programming and harmonic analysis capabilities.
Performance: The filter achieves a Total Harmonic Distortion (THiD) of less than 7% at 40% load, less than 5.5% at 70% load, and less than 5% at 100% load. Efficiency exceeds 95% at 40% load and 98% at 70% and 100% loads. The true power factor is greater than 0.98 across all load levels.
Compliance: The product complies with IEEE519 standards, with application and load-dependent considerations. It is out of scope for IEC61000-3-2, IEC61000-3-12, and IEC61000-3-4 norms.
See more

Catalog excerpts

VLT® Advanced Active Filter AAF 006-1

VLT® Advanced Active Filter AAF 006 A flexible and adaptable solution for central or de-central harmonic mitigation. Danfoss Advanced Active Filters can compensate for individual VLT® drives or can be installed as a compact stand-alone solution at a common point of coupling, compensating for several loads simultaneously. Consequently the filter ensures optimal harmonic suppression independent of the number of loads and their individual load profile. In addition the active filter corrects the power factor and balances the phase load providing an optimal energy utilization. This improves the system efficiency and increases the grid robustness to avoid downtime. E-frame The extensive re-use of proven VLT® components and the modular construction ensures a high reliability and at the same time offers high energy efficiency, back-channel cooling and high enclosure grades without size encrease. The VLT® Advanced Active Filter is easily controlled via the user-friendly LCP, sharing design and programming structure with the VLT® drives series. Without dismounting existing installation, the VLT® Advanced Active Filters are easily retrofitted to the existing installation, where harmonics are increased because of enlarged employment of non-linear loads such as variable speed drives. Voltage range 380 – 480 V AC 50 – 60 Hz Current range 190 A, 250 A, 310 A, 400 A. Up to 4 units can be paralleled for higher power. Enclosure degree Perfect match for: – Industrial automation – igh dynamic H applications – Safety installations Reliable – 100% factory tested – Coated PCBs – >90% components re-used from proven VLT® FC series – Innovative cooling concept User-friendly and flexible – Innovative programming possibilities – Modular design Maximum uptime – Low failure rate – Wide range of options Energy saving – High efficiency – Sleep mode and progressive switching freq. – Power factor correction – Prolonged lifetime of electronics Saves commissioning and operating cost – Low running expenses – Easy serviceability – Low initial investment – High degree of customisation Lower operation costs

 Open the catalog to page 1
VLT® Advanced Active Filter AAF 006-2

The following options are available: n RFI filters n Disconnect n Fuses n Mains shielding VLT® MCT 10 Setup Software VLT® MCT 10 offers advanced programming functionality for all Danfoss drive products, greatly reducing programming and set-up time. VLT® MCT 10 Basic (available free of charge from www.danfoss.com) allows access to a finite number of drives with limited functionality. The advanced edition, offering a higher level of functionality, is available from your Danfoss sales partner. Specifications THiD* at: – 40% load – 70% load – 100% load Efficiency* at: – 40% load – 70% load – 100%...