Selection Guide l VACON® NXP System Drive - 1

Selection Guide l VACON® NXP System Drive Save costs and improve reliability – the easy way Reduce the design cost of a projectbased enclosure to only

Open the catalog to page 1
Selection Guide l VACON® NXP System Drive - 3

The best partner for reliability and performance Customers in heavy industries, such as Marine, Metals and Pulp and Paper, need drive systems that excel in terms of reliable performance. If you can rely on your system, it leaves you with more time and money to spend on optimizing the rest of the application. You can now be sure to receive a drive system that is unmatched in terms of quality and ready in a shorter space of time than ever before. That’s because we have changed our production approach to bring it into line with what customers are after. VACON® NXP System Drive ensures that you...

Open the catalog to page 3
Selection Guide l VACON® NXP System Drive - 4

VACON® NXP System Drive – quality as standard Reliability is key Quick installation VACON® NXP System Drive brings what customers need above all else – consistent and reliable quality guaranteed. We excel in delivering verified and tested solutions that combine VACON® AC drives, DC bus components and options. No need to worry about waiting for technical data, documentation or piloting – we’ve done all that before it reaches your premises. Aside from the quality delivered, VACON® NXP System Drive is also easy to adapt. Engineered sections slot in alongside each other, allowing you to arrange...

Open the catalog to page 4
Selection Guide l VACON® NXP System Drive - 5

This is because the setup is essentially formulated when you order it, meaning system integrators can get on with designing the rest of the application. The fact that the drive system's setup is uniform also means that it's far easier to provide spare parts. Safety and service means a longer lifecycle A complex and wide-ranging solution is not one you want to have to replace, which is why VACON® NXP System Drive is built to last. One of the cornerstones of the relationship with our partners is a commitment to drives performance that goes far beyond the point of purchase. Items such as...

Open the catalog to page 5
Selection Guide l VACON® NXP System Drive - 6

VACON® NXP System Drive configurator Setting up VACON® NXP System Drive couldn’t be easier – our online configuration tool guides you through the whole design process while providing you with the necessary documentation. This is all achieved in a number of simple steps: Now you can play around with the parts to ensure that they meet your needs. The dimensions (height x length x depth) are all listed so that you can ensure the setup fits into the space you have set aside for the system. You enter all the standard process data you will need for the drive system to work as you want it to e.g....

Open the catalog to page 6
Selection Guide l VACON® NXP System Drive - 7

As a user of VACON® NXP System Drive configuration tool, you will have your own profile page which lists all your configurations, drafts and technical history. This allows you to easily keep track of your settings so that you don’t have to spend time looking around for mislaid papers. Engineering process is cut to a minimum Prevents human mistakes from occurring during configuration Preferred configurations can be saved in customer profiles Easy and efficient way to try out implementation options

Open the catalog to page 7
Selection Guide l VACON® NXP System Drive - 8

Auxiliary Device Section (ADS) The auxiliary device section includes the common line-up controls. This section can be customized for all application and segment needs. There is one ADS size available. As standard the ADS section has the following equipment: ■ Indication of the mains status (fault, pre-charging and ON) ■ Auxiliary power supply 24 V, 5 A ■ Auxiliary transformer, 2500 VA 1-phase supply (in bottom of cabinet) ■ Terminals for control and monitoring As pre-engineered standard options, we can provide the following: ■ Emergency stop CAT0 (+PES) ■ Emergency stop CAT1 (+PED) ■...

Open the catalog to page 8
Selection Guide l VACON® NXP System Drive - 9

Non-regenerative Front-end Section (NFS) The non-regenerative front-end section (NFS) includes one or multiple NXN units from the VACON® product family. The NXN is a non-regenerative supply unit that can be utilized in 6-pulse, 12-pulse,18-pulse and 24-pulse systems. As standard the NFS section includes the following: ■ The NXN unit(s) ■ Chokes ■ Terminals for control and indication signals ■ DC fuses for the supply unit ■ AC fuses for the filter As pre-engineered standard options, we can provide the following: ■ UL approved design and components (+NAR) ■ Arc protection (+ADU) ■ Cabinet...

Open the catalog to page 9
Selection Guide l VACON® NXP System Drive - 10

* Only option board and fieldbus options ** Top exit +400 mm can be shared between two sections Inverter Unit Section (IUS) drive The inverter unit section (IUS) includes one or several smaller NXI drives from the VACON® product family. The inverter units are all VACON® NXP drives. As standard the IUS section includes the following: ■ Input fuses (DC fuses) ■ The NXI drive(s) ■ Control box (integrated into the module) ■ Terminals for control and indication signals Inverter Unit Section (IUS) drive The inverter unit section (IUS) includes the largest NXI drives from the VACON® product...

Open the catalog to page 10
Selection Guide l VACON® NXP System Drive - 12

ENGINEERING TOMORROW f f fDanfoss DrivesDanfoss Drives is a world leader in variable speed control of electric motors. We aim to prove to you that a better tomorrow is driven by drives. It is as simple and as ambitious as that. We offer you unparalleled competitive edge through quality, application-optimized products targeting your needs - and a comprehensive range of product lifecycle services. You can rely on us to share your goals. Striving for the best possible performance in your applications is our focus. We achieve this by providing the innovative products and application know-how...