Danfoss Drives VLT® Options
122Pages

{{requestButtons}}

Catalog excerpts

Danfoss Drives VLT® Options - 1

Danfoss Drives Options Portfolio

Open the catalog to page 1
Danfoss Drives VLT® Options - 2

Danfoss Drives VLT® Options Fieldbus VLT® PROFIBUS Converter MCA 114

Open the catalog to page 2
Danfoss Drives VLT® Options - 3

Danfoss Drives VLT ® Options Functional extensions VLT® General Purpose I/O MCB 101 VLT® Encoder Input MCB 102 VLT® PTC Thermistor Card MCB 112 VLT® Relay Card MCB 105 VLT® Safe PLC I/O MCB 108 VLT® VLT® Safety Option MCB 150 series Sensor Input MCB 114 Extended Cascade Controller MCO 101 Programmable controller, relay card & power supply C VLT® Advanced Cascade Controller MCO 102 VLT® Extended Relay Card MCB 113 VLT® Motion Control MCO 305 VLT® Synchronizing Controller MCO 350 VLT® 24 V DC Supply MCB 107 Power options D VLT® Advanced Harmonic Filter AHF 005 & AHF 010 VLT® Sine-wave Filter...

Open the catalog to page 3
Danfoss Drives VLT® Options - 4

Danfoss Drives VACON® Options NX_ family OPT-A series OPT-B series OPT-F series OPT-A series OPT-B series OPT-C series OPT-E series OPT-E series Feedback/ Encoder Fieldbus/ Communication Adapter OPT-D series Functional safety Heat exchangers Heat ex

Open the catalog to page 4
Danfoss Drives VLT® Options - 5

VLT® Fieldbus Options

Open the catalog to page 5
Danfoss Drives VLT® Options - 6

VLT® PROFIBUS DP MCA 101 Operating the AC drive via a fieldbus enables you to reduce the cost of your system, communicate faster and more efficiently, and benefit from an easier user interface. VLT® PROFIBUS DP MCA 101 provides • Wide compatibility, a high level of availability, support for all major PLC vendors, and compatibility with future versions • Fast, efficient communication, transparent installation, advanced diagnosis and parameterization and auto-configuration of process data via GSD-file • Acyclic parameterization using PROFIBUS DP-V1, PROFIdrive or Danfoss FC profile state...

Open the catalog to page 6
Danfoss Drives VLT® Options - 7

VLT® DeviceNet MCA 104 VLT® DeviceNet MCA 104 offers robust, efficient data handling thanks to advanced Producer/Consumer technology. • Support of ODVA’s AC drive profile supported via I/O instance 20/70 and 21/71 secures compatibility to existing systems • Benefit also from ODVA’s strong conformance testing policies, which ensure that products are interoperable EtherNet/IP™ and DeviceNetTM are trademarks of ODVA, Inc. Ordering number 130B1102 standard 130B1202 coated (Class 3C3/IEC 60721-3-3) > Return to VLT® overview 7 | DKDD.EP

Open the catalog to page 7
Danfoss Drives VLT® Options - 8

VLT® CANopen MCA 105 High flexibility and low cost are two of the “cornerstones” for CANopen. The VLT® CANopen MCA 105 option for the VLT® AutomationDrive is fully equipped with both high-priority access to control and status of the drive (PDO Communication) and access to all parameters through acyclic data (SDO Communication). For interoperability the option has implemented the DSP402 AC drive Profile. This all guarantees standardized handling, interoperability and low cost. Ordering number 130B1103 standard 130B1205 coated (Class 3C3/IEC 60721-3-3) > Return to VLT® overview 8 | DKDD.EP.411.

Open the catalog to page 8
Danfoss Drives VLT® Options - 9

VLT® AK-LonWorks MCA 107 VLT® AK-LonWorks MCA 107 is a complete electronic refrigeration and control system for monitoring and controlling refrigeration plants. Connecting this drive to a Danfoss ADAPKOOL® Lon network is really simple. After entering a network address, press a service pin to start the automatic configuration procedure. Ordering number 130B1169 standard 130B1269 coated (Class 3C3/IEC 60721-3-3) > Return to VLT® overview 9 | DKDD.EP.411.A6.0

Open the catalog to page 9
Danfoss Drives VLT® Options - 10

VLT® LonWorks MCA 108 LonWorks is a fieldbus system developed for building automation. It enables communication between individual units in the same system (peer-to-peer) and thus supports decentralizing of control. • No need for main station (master-follower) • Units receive signals directly • Supports Echelon free-topology interface (flexible cabling and installation) • Supports embedded I/O and I/O options (easy implementation of de-central I/O) • Sensor signals can quickly be moved to another controller via bus cables • Certified as compliant with LonMark ver. 3.4 specifications...

Open the catalog to page 10
Danfoss Drives VLT® Options - 11

VLT® BACnet MCA 109 The BACnet protocol is an international protocol that efficiently integrates all parts of building automation equipment from the actuator level to the building management system. Via the BACnet option it is possible to read all analog and digital inputs and control all analog and digital outputs of the VLT® HVAC Drive. All inputs and outputs can be operated independently of the functions of the drive, and thus work as remote I/O: • • • • COV (Change of Value) Synchronization of RTC from BACnet Read/write Property Multiple Alarm/Warning handling Ordering number 130B1144...

Open the catalog to page 11
Danfoss Drives VLT® Options - 12

VLT® PROFIBUS Converter MCA 113 The VLT® PROFIBUS Converter MCA 113 is a special version of the PROFIBUS options that emulates the VLT® 3000 commands in the VLT® AutomationDrive. The VLT® 3000 can be replaced by the VLT® AutomationDrive, or an existing system can be expanded without costly change of the PLC program. For upgrade to a different fieldbus, the installed converter is easily removed and replaced with a new option. This secures the investment without losing flexibility. Ordering number NA standard 130B1245 coated (Class 3C3/IEC 60721-3-3) > Return to VLT® overview 12 | DKDD.EP.411.A

Open the catalog to page 12
Danfoss Drives VLT® Options - 13

VLT® PROFIBUS Converter MCA 114 The VLT® PROFIBUS Converter MCA 114 is a special version of the PROFIBUS options that emulates the VLT® 5000 commands in the VLT® AutomationDrive. The VLT® 5000 can be replaced by the VLT® AutomationDrive, or an existing system can be expanded without costly change of the PLC program. For upgrade to a different fieldbus, the installed converter is easily removed and replaced with a new option. This secures the investment without losing flexibility. The option supports DPV1. Ordering number NA standard 130B1246 coated (Class 3C3/IEC 60721-3-3) > Return to VLT®...

Open the catalog to page 13
Danfoss Drives VLT® Options - 14

VLT® PROFINET MCA 120 VLT® PROFINET MCA 120 uniquely combines the highest performance with the highest degree of openness. The option is designed so that many of the features from the VLT® PROFIBUS MCA 101 can be reused, minimizing user effort to migrate PROFINET, and securing the investment in a PLC program. Ordering number 130B1135 standard 130B1235 coated (Class 3C3/IEC 60721-3-3) 14 | DKDD.EP.411.A6.02 • Same PPO types as the MCA 101 PROFIBUS for easy migration to PROFINET • Built-in web server for remote diagnosis and reading out of basic drive parameters • Support of MRP • Support of...

Open the catalog to page 14

All Danfoss VLT Drives catalogs and technical brochures

  1. VACON® 100

    32 Pages

  2. TP5001 Range

    92 Pages

  3. Danfoss Drives

    12 Pages

  4. VLT®

    20 Pages

  5. VLT 2800

    34 Pages