Group: DANFOSS
Catalog excerpts
Datasheet, technical data Danfoss inverter scroll compressor, VSH088-G General Characteristics IP54 (with cable gland) Approvals : CE certified, UL certified when connected to frequency converter, *Singlepack: Compressor in cardboard box
Open the catalog to page 1Datasheet, accessories and spare parts Danfoss inverter scroll compressor, VSH088-G Rotolock accessories, suction side Rotolock valve, V02 (1-3/4" Rotolock 1-1/8" ODF) Surface sump Surface sump Surface sump Surface sump Belt type cran Belt type cran Belt type cran Belt type cran Belt type cran Belt type cran Belt type cran kcase heater, kcase heater, kcase heater, kcase heater, kcase heater, kcase heater, kcase heater, Miscellaneous accessories Discharge temperature sensor / converter Discharge temperature sensor Discharge temperature converter Acoustic hood for scroll compressor VSH088-G,...
Open the catalog to page 2Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 30 Hz, EN 12900 rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat = 10 K , Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 3Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 30 Hz, ARI rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat= 11.1 K, Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 4Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 35 Hz, EN 12900 rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat = 10 K , Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 5Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 35 Hz, ARI rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat= 11.1 K, Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 6Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 40 Hz, EN 12900 rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat = 10 K , Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 7Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 40 Hz, ARI rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat= 11.1 K, Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 8Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 45 Hz, EN 12900 rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat = 10 K , Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 9Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 45 Hz, ARI rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat= 11.1 K, Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 10Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 50 Hz, EN 12900 rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat = 10 K , Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 11Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 50 Hz, ARI rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat= 11.1 K, Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 12Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 55 Hz, EN 12900 rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat = 10 K , Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 13Datasheet, performance data Danfoss scroll compressor. VSH088-G Performance data at 55 Hz, ARI rating conditions Cooling capacity Power input Current consumption Mass flow to: Evaporating temperature at dew point tc: Condensing temperature at dew point Rating conditions : Superheat= 11.1 K, Subcooling = Pressure switch settings Maximum HP switch setting Minimum LP switch setting LP pump down setting_ Sound power data Sound power level With accoustic hood
Open the catalog to page 14All DANFOSS Refrigeration & Air Conditioning catalogs and technical brochures
-
Shut-off ball valve Type GBC
15 Pages
-
Danfoss Industrial Refrigeration
32 Pages
-
CXH140
6 Pages
-
VZH028-VZH044
4 Pages
-
Danfoss scroll VSH serie -
56 Pages
-
Danfoss scroll VZH serie
6 Pages
-
Counterfeit
3 Pages
-
Level controls
92 Pages
-
ADAP-KOOL ® Catalogue
222 Pages
-
Electromechanical controls
58 Pages
-
compressors MT - MTZ - NTZ
8 Pages
-
Quick Selection Catalogue
359 Pages
-
MCX General Catalogue
48 Pages
-
EVR
2 Pages
-
R32 brochure
5 Pages
Archived catalogs
-
SGN+ and SGI+ sales brochure
2 Pages
-
Apexx™ SLV series
8 Pages