Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B
25Pages

{{requestButtons}}

Catalog excerpts

Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 1

Data sheet Solenoid valves for water shut off and leak detection Solenoid valve range for water leak detection in residential and industrial buildings: • Houses and apartments - Kitchen and bathrooms • Commercial buildings • Industrial buildings Solenoid valves used for shut-off water supply to prevent water damages from leaking systems. y Flow range for water in Kv: 0.7 - 40 m³ / h y Media temperature from 0 – 120 °C y Thread connections: From G 3/8 – G 2 y DN 6 – 50 y Water hammer damped y Built-in filter y Adjustable closing time available

Open the catalog to page 1
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 2

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B EV220T Polymer valve body, NC y WRAS y RoHS Directive 2011/65/EU y - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 (Notified body by Semko) - Pressure Equipment Directive 2014/68/EU y UL recognized Seal material Inlet Outlet G ¾ ext. G ¾ ext. EPDM G ¾ ext. G ¾ ext. EPDM See separate table for AS/AZ coils. ) It is recommended to install a filter in front of the valve. ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of...

Open the catalog to page 2
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 3

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B Function, NC Coil voltage disconnected (Closed) When voltage is disconnected, the armature spring (2) presses the armature (3) down against the pilot orifice (4). Pressure builds up over the diaphragm (5) via the equalizing orifice (6). The diaphragm closes the main orifice (7) as soon as the pressure over the diaphragm equals the inlet pressure. The valve stays closed for as long as voltage remains disconnected. Description Coil Armature spring Armature Pilot orifice Diaphragm...

Open the catalog to page 3
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 4

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B Dimensions and weight ISO 228-1 connection Inlet Outlet G ¾ ext. G ¾ ext. G ¾ ext. G ¾ ext. Mounting angle Capacity diagram Example for water: Capacity for EV220T at a differential pressure of 3 bar: Approx. 7 m3 / h

Open the catalog to page 4
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 5

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B EV220W Brass valve body, NC y WRAS y RoHS Directive 2011/65/EU y - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 y UL recognized Seal material G 3/8 EPDM G 1/2 EPDM G 3/4 EPDM G1 EPDM See separate table for AC/AZ coils ) It is recommended to install a filter in front of the valve. ) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium...

Open the catalog to page 5
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 6

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B Function, NC Coil voltage disconnected (Closed) When voltage is disconnected, the armature spring (2) presses the armature (3) down against the pilot orifice (4). Pressure builds up over the diaphragm (5) via the equalizing orifice (6). The diaphragm closes the main orifice (7) as soon as the pressure over the diaphragm equals the inlet pressure. The valve stays closed for as long as voltage remains disconnected. Description Coil Armature spring Armature Pilot orifice Diaphragm...

Open the catalog to page 6
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 7

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B Mounting angle Capacity diagram Example for water: Capacity for EV220W at a differential pressure of 3 bar: Approx. 7 m3 / h

Open the catalog to page 7
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 8

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B y Enclosure: Up to IP65 / NEMA 4 AS/AZ, Compact UL recognised, clip-on coils y Used with EV220T and EV220W y For UL recognised valves y In accordance with: - RoHS Directive 2011/65/EU - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 y UL recognized Supply voltage Technical data Design Insulation of coil windings Connection Enclosure, IEC 529 Plug type In accordance with UL 429 Class H according to IEC 85 Spade connector in accordance with DIN 43650 form A IP00 with DIN...

Open the catalog to page 8
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 9

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B EV220B 6 - EV220B 12 Brass valve body, NO y WRAS y ACS y PZH y In accordance with: - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 - Pressure Equipment Directive 2014/68/EU y UL recognized Seal material EPDM EPDM Kv Media Max working Differential value temperature pressure pressure [m³/h] [°C] [Bar] [Bar] 0.7 0 – 100 20 0.1 – 10 2.1 0 – 100 10 0.3 – 10 ) It is recommended to install a filter in front of the valve. ) In water applications, exercise the valves at least...

Open the catalog to page 9
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 10

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B EV220B 6 - EV220B 12 DZR Brass valve body, NO y WRAS y In accordance with: - Low Voltage Directive 2014/35/EU - EN60730-1 - EN60730-2-8 - Pressure Equipment Directive 2014/68/EU y UL recognized Seal material EPDM EPDM Kv Media Max working Differential value temperature pressure pressure [m³/h] [°C] [Bar] [Bar] 0.7 0 – 100 20 0.1 – 10 2.1 0 – 100 10 0.3 – 10 ) It is recommended to install a filter in front of the valve. ) In water applications, exercise the valves at least once every...

Open the catalog to page 10
Solenoid valves for water shut off and leak detection Types EV220T, EV220W, EV220B, and EV228B - 11

Data sheet | Solenoid valves for water shut off and leak detection, Types EV220T, EV220W, EV220B, and EV228B Function, NO Coil voltage disconnected (open): When the voltage to the coil (8) is disconnected, the pilot orifice (6) is open. As the pilot orifice is larger than the equalizing orifice (4), the pressure across the diaphragm (7) drops and therefore it is lifted clear of the main orifice (5). The valve will be open for as long as the minimum differential pressure across the valve is maintained, and for as long as the voltage to the coil is disconnected. Description Armature Opening...

Open the catalog to page 11

All Danfoss Industrial Automation catalogs and technical brochures

  1. Wind Power

    8 Pages

  2. Optyma™

    60 Pages

  3. Supermarkets

    28 Pages

  4. Type EV210A

    10 Pages