ENGINEERING TOMORROW Catalogue Optyma™ High Ambient 52 Pack The Cool Outsider, for better Food Preservation R404A/R507, R134a - 60Hz Optyma™ http://cc.danfoss.com
Open the catalog to page 1The Cool Outsider units ensure better Food Preservation and bring benefits for everyone Very high ambient units Optyma™ High Ambient 52 Pack units are designed to operate reliably at very high ambient temperature up to 52°C and are built tough to deliver great performance in demanding environment. They provide stable running conditions and ensure efficient operation of the refrigeration systems which is crucial for better food preservation. Quiet solution Optyma™ High Ambient 52 Pack can be located even in residential areas. They are built with acoustic insulation reducing low sound level...
Open the catalog to page 4Product Range & Features Main product features Reciprocating compressor E-coated micro-channel heat exchanger On site stack Resistant in mounting harsh conditions Plug and play Compact design Capacity & Operating range Cooling capacity range (kW) Cooling capacity range (kW) MBP Rated conditions, Evaporating temperature -10°C. Ambient air temperature +43°C. Superheat 10K. Subcooling 0K LBP Rated conditions, Evaporating temperature -30°C. Ambient air temperature +43°C. Superheat 10K. Subcooling 0K Condensing Unit Limits Ambient Temp [°C] Up to 52°C T Evaporation [°C] Min Max...
Open the catalog to page 5Designation system for the Optyma™ High Ambient 52 Pack
Open the catalog to page 6Catalogue Performance data R404A/R507 LBP Performance with EN13215, SH=10K & SC=0K, R404A Model number Compressor Electrical code Q = 230V - 3ph - 60Hz Compressor & 230V - 1ph - 60Hz Fan N = 230V - 1ph - 60Hz Compressor & Fan V = 380V - 3ph - 60Hz Compressor & 230V - 1ph - 60Hz Fan NTZ type compressor models are reciprocating compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 3% of this value. Power consumption referred at 43°C ambient temperature For more information related to envelope/performance, please refer to...
Open the catalog to page 7Catalogue Performance data R404A/R507 MBP Performance with EN13215, SH=10K & SC=0K, R404A Model number Compressor Electrical code Q = 230V - 3ph - 60Hz Compressor & 230V - 1ph - 60Hz Fan N = 230V - 1ph - 60Hz Compressor & Fan V = 380V - 3ph - 60Hz Compressor & 230V - 1ph - 60Hz Fan MTZ type compressor models are reciprocating compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 3% of this value. Power consumption referred at 43°C ambient temperature For more information related to envelope/performance, please refer to...
Open the catalog to page 8Catalogue Performance data R134a MBP Performance with EN13215, SH=10K & SC=0K, R134a Model number Compressor Electrical code Q = 230V - 3ph - 60Hz Compressor & 230V - 1ph - 60Hz Fan N = 230V - 1ph - 60Hz Compressor & Fan V = 380V - 3ph - 60Hz Compressor & 230V - 1ph - 60Hz Fan MTZ type compressor models are reciprocating compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 3% of this value. Power consumption referred at 43°C ambient temperature For more information related to envelope/performance, please refer to...
Open the catalog to page 9Catalogue Technical Data Code number Low Back Pressure Models LBP 114X7140 OP-LPHE048NTW07Q NTZ048 Q H D7 3250 0.61 1 456 3.4 H2 815 1061 434 5/8" 1/2" 112 90 Medium Back Pressure Models MBP 114X7146 OP-MPZE030MTW07N MTZ018 N Z D7 3250 0.61 1 456 3.4 H2 815 1061 434 1/2" 3/8" 102 80
Open the catalog to page 10Catalogue Spare parts & accessories - MBP
Open the catalog to page 12Catalogue Spare parts & accessories list Component type Acoustic hood 120Z0575 ACOUSTIC HOOD COMP 1CYL Acoustic hood 120Z0576 ACOUSTIC HOOD COMP 2CYL Acoustic hood 120Z0577 ACCOUSTIC HOOD 4CYL Circuit Breaker 118U5084 KIT CIRCUITBREAKER, SCHNEIDER-A9N4P16C Circuit Breaker 118U5085 KIT CIRCUITBREAKER, SCHNEIDER-A9N4P20C Circuit Breaker 118U5086 KIT CIRCUITBREAKER, SCHNEIDER-A9N4P25C Circuit Breaker 118U5087 KIT CIRCUITBREAKER, SCHNEIDER-A9N4P32C Circuit Breaker 118U5088 KIT CIRCUITBREAKER, SCHNEIDER-A9N4P10C Circuit Breaker...
Open the catalog to page 13Catalogue Spare parts & accessories list Component type Component code Component description Additional informations Condenser 118U5081 SPARE PART,DANFOSS OP H2 COATED MCHX Condenser 118U5082 SPARE PART,DANFOSS OP H3 COATED MCHX Condenser 118U5083 SPARE PART,DANFOSS OP H4 COATED MCHX Contactor kit 118U5110 KIT CONT SCHNEI DER-LC1E3201M6 Contactor kit 118U5111 KIT CONT SCHNEI DER-LC1E3801M6 Contactor kit 118U5113 KIT CONT SCHNEI DER-LC1E6501M6 Crankcase heater 120Z0460 PTC 35W EICHENAUER industrialpack50 Discharge gas thermostat...
Open the catalog to page 14Catalogue Dimensions
Open the catalog to page 15Code N: OP-MPZE060 - 068 - 086, OP-LPHE108 - 136 Legend BK black BU blue BN brown GY grey RD red WH white A1 Power Supply Monitoring Relay B1 Fan Speed Controller B2 Dual Pressure Switch C1 Start Capacitor- Compressor E1 Crankcase Heater F1 Main Switch F3,F4 Fuse Control Circuit F5 Discharge Thermostat (LBP only) S1 Door Limit Switch
Open the catalog to page 17Catalogue Electrical wiring diagramsCode N: OP-MPZE108 Supply aonltorlng relay SpannungsOberwachungsrelals relais de protection voltaetrique regulation de vitease pressostat haute et bases p power supply Zuleitung all Mentation 230V 1-/60HZ crankcase heater Kurbelwannenheizung resistance de carter rooa thernostat Raumtherisostat thermostat d'aBbiance 1 egend/Legends/16gende BK black/schwarz/nolr BU blue/blau/bleu BN brown/braun/narron GY grey/grey/gria RD red/rot/rouge WH white/walss/blanc Legend BK black BU blue BN brown GY grey RD red WH white A1 Power Supply Monitoring Relay B1 Fan...
Open the catalog to page 18legend/Legende/lfigende BK black/achwarz/nolr bu blua/blau/blau BN brown/braun/marron GY grey/grey/grls RD red/rot/rouge WH whlte/welss/blanc Legend BK black BU blue BN brown GY grey RD red WH white A1 Power Supply Monitoring Relay B1 Fan Speed Controller B2 Dual Pressure Switch C1 Start Capacitor- Compressor E1 Crankcase Heater F1 Main Switch F3,F4 Fuse Control Circuit F5 Discharge Thermostat (LBP only) S1 Door Limit Switch
Open the catalog to page 19All Danfoss Industrial Automation catalogs and technical brochures
-
Pressure switch Type RT
21 Pages
-
Solenoid valve Type EV310A
11 Pages
-
Pressure switch RT
17 Pages
-
MBC 5000 and MBC 5100
6 Pages
-
Wind Power
8 Pages
-
Pressure switch Type BCP
7 Pages
-
Danfoss Link™
14 Pages
-
Thermostatic Radiator Valve,
12 Pages
-
Electric Heating
40 Pages
-
Hydronic Specialties
48 Pages
-
Optyma™ Semi-Hermetic
22 Pages
-
Optyma™
60 Pages
-
Supermarkets
28 Pages
-
Hydronic Balancing & Control
12 Pages
-
HGM-PGM Gas detector
4 Pages
-
Danfoss Bond Buff er P3
2 Pages
-
Automotive Power Modules
4 Pages
-
Danfoss Product catalogue
68 Pages
-
AK-PC 772Mini-booster
2 Pages
-
Danfoss Service Thermostats
2 Pages
-
Clean Grid Solutions
44 Pages
-
Type EV210A
10 Pages
-
Industrial sensors and switches
12 Pages
-
Marine applications
12 Pages
-
Mobile Hydraulic applications
12 Pages
-
Temperature sensors overview
2 Pages
-
Switches overview
2 Pages
-
Fluid controls overview
5 Pages
-
How to use - Solenoid valves
46 Pages
-
Core Products Catalogue
171 Pages