Introduction
The document introduces the ECORICH Hybrid Hydraulic Unit, emphasizing its energy efficiency and low heat generation due to the use of highly efficient IPM motors. The unit exceeds the IE4 class in efficiency, providing significant energy savings.
Features
  • Energy Savings and Low Heat Generation: The unit achieves high torque and maximum efficiency while minimizing heat generation, thanks to the IPM motor's electromagnetic structure.
  • Compact and Lightweight Design: The unit's footprint is reduced by 9% and its mass by 40% compared to previous models, making installation easier.
  • Environmental Resistance: CE compliance ensures easier approval processes and better adaptability to environmental conditions.
  • Exclusion from High-Efficiency Motor Regulations: The design avoids the need for motor replacements or design changes due to regulatory updates.
Specifications
  • Maximum Operating Pressure: Available in 4 MPa and 7 MPa models.
  • Maximum Flow Rate: Ranges from 14 L/min to 28 L/min depending on the model.
  • Power Supply: 3-phase, AC 200 V (50/60 Hz) and 220 V (60 Hz).
  • Operating Temperature: Ambient temperature ranges from 0 to 40°C, with a tank oil temperature range of 0 to 60°C.
  • Usable Oil: Mineral-oil base hydraulic oil with a viscosity grade of ISO VG32 to 68.
Unit Options
The document lists various unit options such as mounting conversion plates, thermometers, level switches, oil level gauge guards, and magnet separators to enhance compatibility and functionality.
Technical Diagrams
Includes external dimension diagrams, hydraulic circuit diagrams, and pressure-flow rate characteristics graphs for detailed technical insights.
Conclusion
The ECORICH Hybrid Hydraulic Unit represents a significant advancement in hydraulic technology, offering improved energy efficiency, reduced environmental impact, and enhanced operational capabilities.
Overview
The document provides technical specifications and wiring details for the ECORICH Hybrid Hydraulic Unit, highlighting its energy efficiency and advanced motor technology.
Wiring and Connections
Details the wiring diagram, including digital I/O terminal blocks, communication ports for maintenance, and alarm signal terminal blocks. Specifies the use of M4 wiring screws and applicable cable outer diameter.
Communication Features
Includes an RS422/RS485 communication function for maintenance, with specific terminals for TxD, RxD, and DGND connections.
Operational Features
Equipped with digital input and output terminals, alarm contact outputs, and a control/communication cable ground terminal. Supports external power supply connections with a switching capacity of 10 mA to 1 A.
Contact Information
Provides contact details for Daikin's Osaka office and All World Machinery Supply, Inc., a member of the Daikin group.
See more

Catalog excerpts

ECORICH (Design 40 series)-1

ECORICH HYBRID HYDRAULIC UNIT ECORICH Surpassing IE4 class Exceeds standard of high efficiency motor regulation. New Launch with Full Model Change! Highly efficient IPM motors now incorporated for substantial energy savings and low heat generation

 Open the catalog to page 1
ECORICH (Design 40 series)-2

Features  “ECORICH”, a hybrid hydraulic system that realized the world’s first fusion of hydraulics technology with Daikin’s exceptional air conditioning motor/inverter technology, has been a trend setter for energy savings in the hydraulics field.  “ECORICH” has now undergone a model change involving incorporation of highly efficient IPM motors. The significant improvement in energy savings and low heat generation contribute to greater plant energy savings. Fundamental principle of the IPM motor With a rare-earth permanent magnet deeply embedded in the rotor, the IPM motor uses an electromagnetic...

 Open the catalog to page 2
ECORICH (Design 40 series)-3

J Model No. |6 i EHU: ECORICH Series ^ Maximum flow rate i 14: 14 L/min i 25: 25 L/min i 30: 28 L/min ^ Maximum operating pressure i 04: 4 MPa i 07: 7 MPa Design No. i Design 40 series (Incremented at model changes) [Unit option (up to 6 letters of the alphabet, a combination of those tabled below, in alphabetical order when combined)] or [Non-standard control number (3-digit number)] Unit options . ■ Detailed Explanation of Unit Options Code

 Open the catalog to page 3
ECORICH (Design 40 series)-4

■ Pressure - Flow rate characteristics I JI EHU1404 I EHU2504 I EHU2507 I EHU3007 * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 5 L/min maximum . ■ Specifications Model code *1: • The maximum flow rate is the theoretical value, not the guaranteed value. • Refer to the specification sheet (outside drawing) for detailed specifications. • This hydraulic unit is equipped with built-in safety valves. *2: • Use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic), water-glycol hydraulic...

 Open the catalog to page 4
ECORICH (Design 40 series)-5

^ ■ Hydraulic Circuit Diagram I List of parts Part No.

 Open the catalog to page 5
ECORICH (Design 40 series)-6

Internal terminal layout (with the controller cover open) Control/communication cable ground terminal Wiring screw (M4) Digital output X1 Digital I/O terminal block (plug-in terminals) Digital input Communication port for maintenance Control/communication cable port * Only when the “C: With RS422/485 communications function” option is selected Power cable port (φ23 hole) COM ALMb (Error: Closed) ALMa (Error: Opened) Power supply terminal block (M4 screw terminal) X1 Power cable ground terminal Power cable ground terminal Wiring screw (M4) Control power supply input 1-phase AC 200 V (50 Hz), 200...

 Open the catalog to page 6
ECORICH (Design 40 series)-7

 ECORICH Handling Precautions These are the minimum requirements for use of the ECORICH. For details, refer to the unit’s Instruction Manual.  Ambient conditions 1. Ambient temperature: 0 to 40°C, ambient humidity: 85% RH maximum (with no condensation), altitude: 1,000 m maximum, to be used indoors.  Hydraulic oil 1. Use mineral-oil base hydraulic oil. Use of hydraulic oils other than mineral-oil based type (e.g. hydrous/synthetic) is prohibited. 2. Use hydraulic oil equivalent to ISO VG32 to 68. Keep the viscosity of the hydraulic oil within the range from 15 to 400 mm2/s, and keep tank oil...

 Open the catalog to page 7
ECORICH (Design 40 series)-8

DAI KIN INDUSTRIES, LTD. Oil Hydraulic Equipment Osaka Office YODOGAWA PLANT 1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan Phone: 81-6-6349-4475 Home Page: http://www.daikinpmc.com/en/ All World Machinery Supply, Inc. A member of Daikin group 6164 All World Way, Roscoe, IL 61073, U. S. A. Phone: +1-815-943-9111 Home Page: http://www.allworldmachinery.com/ •Contents in this catalog are subject to change for improvement without prior notice.