AKZ9 SERIES
32Pages

{{requestButtons}}

Catalog excerpts

AKZ9 SERIES - 1

RoHS Compliant Principle/ Piping system diagram Description of model symbols Cooling capacity characteristic chart Outside dimension diagram Optional parts Thermistor Expansion board for main machine communication Supporting information Control panel/Operation mode/Setting method Electric schematic diagram Electric wiring connection instruction diagram High-accuracy, Energy-saving, Compact Environmentally Friendly Inverter Oil Cooling Unit Service network

Open the catalog to page 1
AKZ9 SERIES - 2

Circulation type RoHS Compliant Features Further Evolution of High-accuracy Temperature Control Achieve high energy-saving performance ■Our acclaimed ±0.1℃ oil temperature control has been extended to cover an even wider range. ■Achieve high energy-saving performance with the adoption of a Daikin original IPM motor and R410A refrigerant for high COP characteristics. ■The cooling capacity resolution in the low-load range has been improved through optimal control of the compressor and electronic expansion valve. ■The power consumption can be checked on Reduction of the operation panel....

Open the catalog to page 2
AKZ9 SERIES - 3

Features Functions featured ■The ingress protection of the control box has been upgraded (equivalent to IP54). ■Refrigerant gas leakage detection alarm function An alarm signal is output when the refrigerant gas would be leaked (as cooling circuit failure). ■Oil temperature warning function A warning signal can be output when the oil temperature or air temperature strays outside arbitrarily setting range. ■Electronic components resistant to sulfidization have been adopted. Higher durability for long-distance transportation ■Auto tuning function This function substantially cuts the time...

Open the catalog to page 3
AKZ9 SERIES - 4

Principle and overall system diagram Control board Inlet oil temperature thermistor(To *1) Outlet oil temperature thermistor(To *2) Oil temperature control thermistor(To *3) 〈Optional part〉             Room temperature thermistor(To *4) Machine temperature synchronous thermistor(To *5) 〈Optional part〉 Pressure reducing mechanism Principle and overall system diagram/series piping system diagram Bypass mechanism Evaporator Cooler Machine tools Note) Refer to Pages 19 and 1.  20 for optional parts. 2. Refer to Pages 21 and  22 for detailed setting   and others. 【Refrigerating cycle】 A...

Open the catalog to page 4
AKZ9 SERIES - 5

OILCOOLING UNIT Description of model symbols AKZ SERIES Specification identification code - : Used for units with a semi-standard specification or a combination of semi-standard specifications Single letter : When ^below is a serial number, the semi-standard specification is identified here with a single letter of the alphabet. Symbol for semi-standard types (B,C,H,T) B : With breaker 046:Different voltage AC220,230V 50/60Hz C : Compliance with CE 047 : Different voltage AC380,400,415V 50/60Hz T : With tank Or, a serial number (three numerical digits) Non-standard...

Open the catalog to page 5
AKZ9 SERIES - 6

Oil Cooling Unit horsepower(HP) Note) *1. The cooling capacity represents the value at the standard point(inlet oil temperature: 35°C, room temperature: 35°C, oil for use: ISO VG32). The tolerance of the product is approx .±5%. *2. Be sure to use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the unit. The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us. *3. There are three types of different voltage specifications depending on the power source: —046, —047 and...

Open the catalog to page 6
AKZ9 SERIES - 7

Oil Cooling Unit horsepower (HP) Model name Stan dard Circuit voltage Stan dard Different voltage specifications *3 Different voltage specifications *3 Cooling capacity 50/60Hz) kW ( Heater Max. power consumption 200V 60Hz Max. consumption current 220V 60Hz Transformer capacity Ivory white Exterior color Outside dimensions H×W×D) mm 1110×470×560 1375×470×580 1410×470×560 1360×470×590 1220×560×680 1485×560×700 1520×560×680 1470×560×659 ( Equivalent to 2.2kW Brazed plate type Cross-fin coil type Condenser Motor Compressor (Totally enclosed DC swing type) Open pressure Room temperature or machine...

Open the catalog to page 7
AKZ9 SERIES - 8

Cooling capacity characteristic chart Oil temperature = Room temperature +10℃ Oil temperature = Room temperature 1,200 Oil temperature = Room temperature −10℃ Oil temperature = Room temperature +10℃ Cooling capacity characteristic chart 3,000 Oil temperature = Room temperature Oil temperature = Room temperature −10℃ 5,000 Oil temperature = Room temperature +10℃ Oil temperature = Room temperature Oil temperature = Room temperature −10℃

Open the catalog to page 8
AKZ9 SERIES - 9

7,000 Oil temperature = Room temperature +10℃ Oil temperature = Room temperature Oil temperature = Room temperature −10℃ 10,000 Oil temperature = Room temperature +10℃ 8,000 Oil temperature = Room temperature Oil temperature = Room temperature −10℃ Cooling capacity characteristic chart ■Solid line    :When operated at 60Hz ■Broken line     When operated at 50Hz : 1. The mark “○” shows the standard point. (Room temperature: 35℃ Inlet oil temperature : 35℃ Oil for use: ISO VG32) 2. The cooling capacity differs depending on conditions such as roo

Open the catalog to page 9
AKZ9 SERIES - 10

Outside dimension diagram Note) Refer to Page 5 for more details. The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not. | AKZ149(-B,-C,-046) I Marions) Withbreakeij t:.mpto.thca Different voltages (without transformer) |AKZ149-H| With heatej Part No.

Open the catalog to page 10
AKZ9 SERIES - 11

*The yellow line on the oil level gauge shows the highest oil level and the red line the lowest oil level. (Keep the oil level between the yellow and red lines during use.) | AKZ149-047,-048 | Different voltages (With transformer) 3art No. AKZ 9 SERIES Outside dimension diagram Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.

Open the catalog to page 11

All Daikin PMC catalogs and technical brochures

  1. AKC9 SERIES

    28 Pages

  2. AKJ9 SERIES

    28 Pages

  3. GK242B

    12 Pages

  4. GK250

    52 Pages