AKJ9 SERIES

AKJ9 SERIES
1 / 28 PagesView full catalog

AKJ9 SERIES

Product catalog summary
System Overview:
The document details the 9AKJ series oil cooling units designed for immersion in cutting and grinding fluids. It operates on a refrigerating cycle involving compression, cooling, liquefaction, expansion, and evaporation of refrigerant gas to absorb heat from the coolant.

Refrigerating Cycle:
  • The compressor converts refrigerant gas into high-temperature, high-pressure gas.
  • The condenser cools this gas into a liquid.
  • An electronic expansion valve reduces pressure, allowing the liquid to evaporate in the cooling coil, absorbing heat.
  • A hot gas bypass valve adjusts cooling capacity at low loads.

Specifications:
  • Cooling capacities range from 1.8 kW to 15.0 kW.
  • Units operate on various voltages, including AC 220 to 480 V at 50/60 Hz.
  • Specific power and current requirements are detailed in the document.

Options and Combinations:
  • Options include breakers, CE compliance, heaters, and different voltage types.
  • Option symbols indicate configurations, such as -B for breaker, -C for CE compliance, and -H for heater.

Operating Range and Conditions:
  • Use within specified temperature ranges to avoid failure.
  • Acceptable fluids include water-soluble cutting fluids, lubrication oils, and industrial water.
  • Protection devices include thermostats, pressure switches, and leakage detectors.

Additional Notes:
  • Includes diagrams and tables for power consumption and operating conditions.
  • Special specifications available upon consultation.
Control Panel Overview:
The control panel features indicators and keys for operation. The power lamp (green) indicates power supply, while the timer mode lamp (red) blinks when stopped in timer mode. Keys allow mode selection and setting adjustments.

Operation Modes:
Includes normal, monitor, and setting modes, each allowing different functionalities like data monitoring or setting adjustments. Default settings for standard machines are provided.

Temperature Control:
Outlines temperature control modes for AKJ9 and AKC9 series, including fixed temperature control and synchronization with room or machine temperatures.

Monitoring and Alarms:
In monitor mode, users can check data points like machine body temperature and power consumption. Alarms and warnings are indicated by blinking or steady lamps.

Electrical Schematics:
Provides detailed electrical schematics for AKJ9 and AKC9 series, including components like thermistors and transformers.
Maintenance and Inspection Guidelines:
  • Danger and Caution Notices: Follow instructions to avoid serious injury or death. Warnings include avoiding explosive atmospheres and ensuring compliance with safety laws.
  • Safe Operation Instructions: Use equipment as specified, avoid atypical environments, and ensure proper installation and grounding. Regular maintenance includes cleaning air filters and cooling coils.
  • Handling Refrigerant Leaks: Ventilate areas, avoid skin contact, and seek medical attention if necessary.
  • Installation and Transport: Ensure equipment is on a level foundation, avoid tilting beyond 30 degrees, and use proper hoisting techniques.
  • Wiring and Piping: Should be performed by qualified personnel, using commercial power supplies and adhering to wiring diagrams.
Heat Generation and Cooling:
  • Heat Calculation: Use provided formulas to estimate heat generation from cutting and grinding fluid systems.
  • Cooling Unit Selection: Consider maximum fluid temperature rise and use the provided method for selecting appropriate oil cooling units.
Product Information:
  • Series Overview: Details on AKJ9 and AKC9 series, including system configurations and specifications.
  • Service Network: Daikin provides service through sales agents in various countries, including China, Korea, Taiwan, Thailand, Singapore, India, and the U.S.
See more

Catalog excerpts

AKJ9 SERIES-1

AKJ9 SERIES (Immersion type) Overview / Features Home Page: http://www.daikinpmc.com/en/ Please contact Daikin Sales Counter for servicing of Oil Cooling Unit in countries outside Japan. Daikin is ready to offer you service in conjunction with the sales agents of our Air-conditioning and Hydraulic Divisions located in seven countries and regions worldwide. Locations Shanghai External Dimension Diagram Installation Dimension Diagram AKC9 SERIES (Circulating type) Overview/Features System Configuration Cooling Capacity Characteristic Chart Internal Pressure Loss Flow Rate Characteristics for Models With a Pump Optional Parts Company name ◎ DAIKIN HYDRAULICS (SUZHOU) 上海分公司(Shanghai Branch) External Dimension Diagram AKJ AKC Overseas service network Cooling Capacity Characteristic Chart YODOGAWA PLANT 1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan Specifications and Operating range Osaka Office System Overview Piping System Diagram Circulating type Immersion type Dalian China ◎ DAIKIN HYDRAULICS 大連分公司(Dalian Branch) Extension board for main machine communication ◎ DAIKIN HYDRAULICS 北京営業所(Beijing Office) Supporting Information ◎ DAIKIN HYDRAULICS (SUZHOU) 広州営業所(Guangzhou Office) Control Panel ◎ DAIKIN HYDRAULICS (SUZHOU) 瀋陽営業所(Shenyang Office) Operation Mode/Setting Method Electric Schematic Diagram Electric Wiring Connection Instruction Diagram Method of selection of Oil Cooling Unit SIAM DAIKIN SALES CO., LTD. DAIKIN AIR CONDITIONING INDIA PVT.LTD DELHI BRANCH HO TAI DEVELOPMENT CO.,LTD. ◎ ZICOM Immersion type Circulating type WORLD MACHINERY ◎Sales agents of hydraulic equipment. Others are the sales agent of air conditioning equipment. ●Contents in this catalog are subject to change for improvement without prior notice.

 Open the catalog to page 1
AKJ9 SERIES-2

cooling coil construction suppresses the adhesion and accumulation of cutting/grinding chips. Increased tolerance of harsh factory conditions including mist and dust Overview / Features ingress protection of the control box has been upgraded (equivalent to IP54). ■ Sulfur-free parts have been adopted for electronic components. Immersion-type oil cooling unit mounted directly on the coolant tank Increased tolerance of long-distance transportation It is a cooler that is placed on the coolant tank and cools the fluid inside the tank directly with a cooling coil. specifications for vibration durability...

 Open the catalog to page 2
AKJ9 SERIES-3

cooling coil construction suppresses the adhesion and accumulation of cutting/grinding chips. Increased tolerance of harsh factory conditions including mist and dust Overview / Features ingress protection of the control box has been upgraded (equivalent to IP54). ■ Sulfur-free parts have been adopted for electronic components. Immersion-type oil cooling unit mounted directly on the coolant tank Increased tolerance of long-distance transportation It is a cooler that is placed on the coolant tank and cools the fluid inside the tank directly with a cooling coil. specifications for vibration durability...

 Open the catalog to page 3
AKJ9 SERIES-4

Temperature regulator Compressor protective thermostat (-C only) From main machine *2 Discharged gas temperature thermistor Electronic expansion valve 1 Oil cooling unit identification code *3 Condensing temperature thermistor S3 High-pressure PH pressure switch (-C only) Room temperature thermistor *5 Intake gas temperature thermistor Low pressure gauge port Stirring motor Supply pump Option Symbol Options and their combinations (Refer to the following table.) Special specifications AKJ:High-accuracy inverter controlled oil cooling unit    Immersion type for cutting/grinding fluid (oil) *4 Electronic...

 Open the catalog to page 4
AKJ9 SERIES-5

D Oil cooling unit identification code AKJ : High-accuracy inverter controlled oil cooling unit Immersion type for cutting/grinding fluid (oil) ^ Cooling capacity (kW) 18: Cooling capacity 1.8 kW 35: Cooling capacity 3.5 kW 45: Cooling capacity 4.5 kW 56: Cooling capacity 5.6 kW 90: Cooling capacity 9.0 kW 150: Cooling capacity 15.0 kW Option Symbol Options and their combinations (Refer to the following table.) Special specifications -XXX (3-digit number), CXXX (3-digit number), etc. Please consult us about detailed information. ^ Symbol of series (Symbol to represent model change) E CO U) CO b E 0...

 Open the catalog to page 5
AKJ9 SERIES-6

SERIES Oil cooling unit horsepower (HP) M. The cooling capacity indicates the value at the standard point (tank fluid temperature: 35°C, room temperature: 35°C, Fluid used : Water for AKJ 1509 / Oil; ISO VG 32 for others). This unit has about ±5% of product tolerance. c2. Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the machine. The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us. 3. There are the following three types of different voltage specifications. AC220,...

 Open the catalog to page 6
AKJ9 SERIES-7

9akj-^series Oil cooling unit horsepower (HP) Specifications and Operating range AKJ9 SERIES Refer to Page 5 for explanatory notes. | Operating range | Note: 1. The mark ◎ shows the standard point. 2. Be sure to use the unit within the range of use specified in [ (Use outside this range may cause unit failure.) Tank fluid temperature (°C) 6

 Open the catalog to page 7
AKJ9 SERIES-8

Cooling Capacity Characteristic Chart Cooling Capacity Characteristic Chart Solid line When operated at 60 Hz Tank fluid temperature = Room temperature −10°C Tank liquid temperature = Room temperature Tank liquid temperature = Room temperature +10°C Broken line When operated at 50 Hz Solid line When operated at 60 Hz Broken line When operated at 50 Hz 3,500 3,000 2,500 2,000 1,500 Tank liquid temperature = Room temperature Tank fluid temperature = Room temperature –10°C Solid line When operated at 60 Hz Tank liquid temperature = Room temperature +10°C Tank liquid temperature = Room temperature...

 Open the catalog to page 8
AKJ9 SERIES-9

Cooling Capacity Characteristic Chart Cooling Capacity Characteristic Chart Solid line When operated at 60 Hz Tank fluid temperature = Room temperature −10°C Tank liquid temperature = Room temperature Tank liquid temperature = Room temperature +10°C Broken line When operated at 50 Hz Solid line When operated at 60 Hz Broken line When operated at 50 Hz 3,500 3,000 2,500 2,000 1,500 Tank liquid temperature = Room temperature Tank fluid temperature = Room temperature –10°C Solid line When operated at 60 Hz Tank liquid temperature = Room temperature +10°C Tank liquid temperature = Room temperature...

 Open the catalog to page 9

All Daikin PMC catalogs and technical brochures

  1. AKC9 SERIES

    28  Pages

  2. AKZ9 SERIES

    32  Pages

  3. GK242B

    12  Pages

  4. GK250

    52  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.