Overview: The document provides comprehensive details on Daikin Hydraulics' oil cooling units, specifically the AKJ9 and AKC9 series, designed to cool hydraulic and cutting oils, enhance machining accuracy, and extend hydraulic system life.
Specifications and Features: The AKJ9 series is an immersion-type unit, while the AKC9 series is a circulating type. Both offer precise temperature control within ±0.1°C, are compact, energy-efficient, and include predictive maintenance features to reduce downtime.
System Overview: Includes system configuration diagrams, nomenclature, and specifications, highlighting cooling capacity, installation dimensions, and optional customization parts.
Performance and Maintenance: Features enhanced durability for harsh conditions and long-distance transport, with functions like refrigerant gas shortage detection, temperature warnings, and autotuning for optimized performance and maintenance.
Applications: Suitable for industrial applications such as machine tools and industrial machines like molding machines and presses.
Optional Features: Lists optional specifications like different voltage types and CE compliance for tailored solutions.
Energy Efficiency: Achieves high energy-saving performance using Daikin's IPM motor and R410A refrigerant, significantly reducing power consumption compared to non-inverter models.
Additional Information: Mentions the Hybrid-Win software tool for monitoring unit status via PC and details on the global sales and service network.
System Overview and Refrigerating Cycle: Describes the refrigerating cycle of the 9AKJ series, detailing the process from compression to evaporation and the role of the hot gas bypass valve in adjusting cooling capacity.
Specifications and Options: Details models with cooling capacities from 1.8 kW to 15.0 kW, including options like breakers and heaters, with specifications for power requirements and protective features.
Electrical and Mechanical Specifications: Outlines voltage types, power consumption, and protective devices like thermostats and pressure switches for safe operation.
Operating Conditions and Limitations: Emphasizes operating within specified temperature ranges and fluid types to prevent failures.
Additional Notes: Highlights installation requirements, use of transformers, and maintaining voltage fluctuations within limits.
Control Panel Overview: Features indicators and keys for operation, with modes like normal, monitor, and setting, and alarms indicated by blinking lamps.
Operation Modes: Describes various modes and default settings, with specific temperature ranges for different modes.
Temperature Control: Offers modes for maintaining fixed temperatures or synchronizing with room/machine temperatures, requiring optional parts for certain modes.
Monitoring and Alarms: In monitor mode, users can check data like temperatures and power consumption, with alarms indicated by specific lamps.
Electrical Schematics: Includes detailed diagrams for understanding electrical setup and troubleshooting.
Maintenance and Inspection Guidelines:
  • Danger and Caution Notices: Warns against explosive atmospheres, disassembling equipment, and stresses compliance with safety laws.
  • Safe Operation Instructions: Advises using equipment as specified, avoiding atypical environments, and ensuring proper installation and grounding.
  • Handling Refrigerant Leaks: Recommends ventilation, avoiding skin contact, and seeking medical attention if necessary.
  • Installation and Transport: Advises on level foundation installation, avoiding excessive tilting, and proper hoisting techniques.
  • Wiring and Piping: Should be done by qualified personnel, ensuring proper grounding and breaker installation.
  • Heat Generation Estimation: Provides formulas for calculating heat generation, emphasizing testing on actual machines.
Technical Specifications and Features:
  • AKJ9 and AKC9 Series: Details system overview, piping diagrams, specifications, cooling capacity, and installation dimensions.
  • Optional Parts and Accessories: Includes thermistors and extension boards for communication with main machines.
  • Control and Operation: Instructions on operation modes, setting methods, and electric schematic diagrams.
Service and Support:
  • Global Service Network: Lists Daikin's service locations across various countries with contact information for sales and service support.
See more

Catalog excerpts

AKC9 SERIES-1

AKJ9 SERIES (Immersion type) Overview / Features Home Page: http://www.daikinpmc.com/en/ Please contact Daikin Sales Counter for servicing of Oil Cooling Unit in countries outside Japan. Daikin is ready to offer you service in conjunction with the sales agents of our Air-conditioning and Hydraulic Divisions located in seven countries and regions worldwide. Locations Shanghai External Dimension Diagram Installation Dimension Diagram AKC9 SERIES (Circulating type) Overview/Features System Configuration Cooling Capacity Characteristic Chart Internal Pressure Loss Flow Rate Characteristics for Models With a Pump Optional Parts Company name ◎ DAIKIN HYDRAULICS (SUZHOU) 上海分公司(Shanghai Branch) External Dimension Diagram AKJ AKC Overseas service network Cooling Capacity Characteristic Chart YODOGAWA PLANT 1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan Specifications and Operating range Osaka Office System Overview Piping System Diagram Circulating type Immersion type Dalian China ◎ DAIKIN HYDRAULICS 大連分公司(Dalian Branch) Extension board for main machine communication ◎ DAIKIN HYDRAULICS 北京営業所(Beijing Office) Supporting Information ◎ DAIKIN HYDRAULICS (SUZHOU) 広州営業所(Guangzhou Office) Control Panel ◎ DAIKIN HYDRAULICS (SUZHOU) 瀋陽営業所(Shenyang Office) Operation Mode/Setting Method Electric Schematic Diagram Electric Wiring Connection Instruction Diagram Method of selection of Oil Cooling Unit SIAM DAIKIN SALES CO., LTD. DAIKIN AIR CONDITIONING INDIA PVT.LTD DELHI BRANCH HO TAI DEVELOPMENT CO.,LTD. ◎ ZICOM Immersion type Circulating type WORLD MACHINERY ◎Sales agents of hydraulic equipment. Others are the sales agent of air conditioning equipment. ●Contents in this catalog are subject to change for improvement without prior notice.

 Open the catalog to page 1
AKC9 SERIES-2

cooling coil construction suppresses the adhesion and accumulation of cutting/grinding chips. Increased tolerance of harsh factory conditions including mist and dust Overview / Features ingress protection of the control box has been upgraded (equivalent to IP54). ■ Sulfur-free parts have been adopted for electronic components. Immersion-type oil cooling unit mounted directly on the coolant tank Increased tolerance of long-distance transportation It is a cooler that is placed on the coolant tank and cools the fluid inside the tank directly with a cooling coil. specifications for vibration durability...

 Open the catalog to page 2
AKC9 SERIES-3

cooling coil construction suppresses the adhesion and accumulation of cutting/grinding chips. Increased tolerance of harsh factory conditions including mist and dust Overview / Features ingress protection of the control box has been upgraded (equivalent to IP54). ■ Sulfur-free parts have been adopted for electronic components. Immersion-type oil cooling unit mounted directly on the coolant tank Increased tolerance of long-distance transportation It is a cooler that is placed on the coolant tank and cools the fluid inside the tank directly with a cooling coil. specifications for vibration durability...

 Open the catalog to page 3
AKC9 SERIES-4

Temperature regulator Compressor protective thermostat (-C only) From main machine *2 Discharged gas temperature thermistor Electronic expansion valve 1 Oil cooling unit identification code *3 Condensing temperature thermistor S3 High-pressure PH pressure switch (-C only) Room temperature thermistor *5 Intake gas temperature thermistor Low pressure gauge port Stirring motor Supply pump Option Symbol Options and their combinations (Refer to the following table.) Special specifications AKJ:High-accuracy inverter controlled oil cooling unit    Immersion type for cutting/grinding fluid (oil) *4 Electronic...

 Open the catalog to page 4
AKC9 SERIES-5

D Oil cooling unit identification code AKJ : High-accuracy inverter controlled oil cooling unit Immersion type for cutting/grinding fluid (oil) ^ Cooling capacity (kW) 18: Cooling capacity 1.8 kW 35: Cooling capacity 3.5 kW 45: Cooling capacity 4.5 kW 56: Cooling capacity 5.6 kW 90: Cooling capacity 9.0 kW 150: Cooling capacity 15.0 kW Option Symbol Options and their combinations (Refer to the following table.) Special specifications -XXX (3-digit number), CXXX (3-digit number), etc. Please consult us about detailed information. ^ Symbol of series (Symbol to represent model change) E CO U) CO b E 0...

 Open the catalog to page 5
AKC9 SERIES-6

SERIES Oil cooling unit horsepower (HP) M. The cooling capacity indicates the value at the standard point (tank fluid temperature: 35°C, room temperature: 35°C, Fluid used : Water for AKJ 1509 / Oil; ISO VG 32 for others). This unit has about ±5% of product tolerance. c2. Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the machine. The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us. 3. There are the following three types of different voltage specifications. AC220,...

 Open the catalog to page 6
AKC9 SERIES-7

9akj-^series Oil cooling unit horsepower (HP) Specifications and Operating range AKJ9 SERIES Refer to Page 5 for explanatory notes. | Operating range | Note: 1. The mark ◎ shows the standard point. 2. Be sure to use the unit within the range of use specified in [ (Use outside this range may cause unit failure.) Tank fluid temperature (°C) 6

 Open the catalog to page 7
AKC9 SERIES-8

Cooling Capacity Characteristic Chart Cooling Capacity Characteristic Chart Solid line When operated at 60 Hz Tank fluid temperature = Room temperature −10°C Tank liquid temperature = Room temperature Tank liquid temperature = Room temperature +10°C Broken line When operated at 50 Hz Solid line When operated at 60 Hz Broken line When operated at 50 Hz 3,500 3,000 2,500 2,000 1,500 Tank liquid temperature = Room temperature Tank fluid temperature = Room temperature –10°C Solid line When operated at 60 Hz Tank liquid temperature = Room temperature +10°C Tank liquid temperature = Room temperature...

 Open the catalog to page 8
AKC9 SERIES-9

Cooling Capacity Characteristic Chart Cooling Capacity Characteristic Chart Solid line When operated at 60 Hz Tank fluid temperature = Room temperature −10°C Tank liquid temperature = Room temperature Tank liquid temperature = Room temperature +10°C Broken line When operated at 50 Hz Solid line When operated at 60 Hz Broken line When operated at 50 Hz 3,500 3,000 2,500 2,000 1,500 Tank liquid temperature = Room temperature Tank fluid temperature = Room temperature –10°C Solid line When operated at 60 Hz Tank liquid temperature = Room temperature +10°C Tank liquid temperature = Room temperature...

 Open the catalog to page 9

All Daikin PMC catalogs and technical brochures

  1. AKJ9 SERIES

    28  Pages

  2. AKZ9 SERIES

    32  Pages

  3. GK242B

    12  Pages

  4. GK250

    52  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.