1. Catalogs
  2. Daikin Applied
  3. Destiny® Indoor Air Handler

Destiny® Indoor Air Handler

Destiny® Indoor Air Handler
1 / 28 PagesView full catalog

Destiny® Indoor Air Handler

Product catalog summary
Introduction
The document details the Destiny® Indoor Air Handler models 002 to 030, available in horizontal and vertical configurations, focusing on specifications, features, and benefits for efficient indoor air management.
Certification
The units are AHRI certified per AHRI Standard 430 and comply with various industry standards.
Smoke Control and Management Systems
Design and approval by a registered professional engineer are necessary to meet local fire codes and NFPA requirements for smoke and fume control.
Features and Benefits
The Destiny air handlers offer flexibility with configurations, motor options, and features like adjustable motor mounts, FC centrifugal blowers, anti-microbial coated drain pans, and double-wall construction for enhanced performance and maintenance.
The Destiny Advantage
These air handlers are versatile for blower coil and low-pressure applications, supporting various configurations and designed for easy maintenance.
Flexibility
Units can be configured for chilled water or direct expansion cooling, and hot water or electric heat, with flexible installation options.
Indoor Air Quality
Compliant with ASHRAE Standard 62.1-2001, the units support superior indoor air quality and a quiet environment.
Unit Construction
Offers various coil selections and filter options, with motors available in different sizes and efficiencies.
Mixing Section Option
An optional mixing section with low leak dampers is available for specific applications.
Variable Frequency Drive (VFD)
Provides adjustable speed control for fan motors, enhancing efficiency.
Electric Heat Option
Optional electric heat section with various staging and control options.
Double-Wall Construction
Features solid double-wall panels with foam-injected insulation for superior thermal barriers.
Sloped Drain Pan
Anti-microbial coated drain pans promote complete drainage and prevent microbial growth.
Cabinets and Service Access
Removable panels and optional hinged doors facilitate maintenance and service.
Quiet Blower and Motor Assembly
High-efficiency blowers and motors with isolation systems minimize vibration and noise.
Starters and Disconnects
Factory-mounted control boxes reduce field labor and installation costs.
Option Summary
Includes access panels, filter options, special options like external prefilter, base rail, and modular design for vertical units.
Application Considerations
Guidelines for mounting, ductwork, piping, and vibration isolation to ensure optimal performance.
Air Supply Systems and Fan Laws
Discusses static pressure variations and fan laws for calculating effects of fan speed and air density changes.
Physical Data
Details component and section weights for various unit sizes and configurations.
Specifications
Includes motor weights, coil water weights, filter sizes, and fan data.
Procedures
Outlines arrangement and connection sizes for drain pans.
Performance Data
Provides fan and coil data, including performance limits and specifications.
Standards and Recommendations
Includes recommendations for electric heat data and cabinet dimensions.
Key Data from Tables
Summarizes motor weights, coil water weights, filter sizes, drain pan connection sizes, fan data, coil data, electric heat data, and cabinet dimensions.
Overview
Provides detailed specifications and dimensions for Daikin's Destiny Indoor Air Handlers.
Engineering Guide Specifications
Includes references to standards, submittal requirements, and product details.
Key Features
Highlights air handler casing, supply fan, and cooling and heating sections.
Specifications
Details on tubes, coil casings, refrigerant connections, and testing.
Drain Pan
Constructed from antibacterial coated materials with a sloping pitch for drainage.
Electric Heating Coils
Factory-installed with primary and secondary protection circuits.
Filters
Includes various filter types and MERV ratings.
Mixing Box
Optional construction as per air handler casing specifications.
Installation
Should follow manufacturer's instructions.
Additional Information
Training, warranty, and service details are available through Daikin's website.
See more

Catalog excerpts

Destiny® Indoor Air Handler-1

Destiny® Indoor Air Handler Horizontal Configuration Vertical Configuration

 Open the catalog to page 1
Destiny® Indoor Air Handler-2

Smoke Control and Management Systems . . . . . . . . 2 Piping and Drain Pan Traps . . . . . . . . . . . . . . . . . . . 9 Air Supply Systems and Fan Laws . . . . . . . . . . . . . . 9 Mixing Section Option . . . . . . . . . . . . . . . . . . . . . . 5 Component and Section Weights . . . . . . . . . . . . . . . 11 Variable Frequency Drive (VFD) . . . . . . . . . . . . . . 6 Electric Heat Option . . . . . . . . . . . . . . . . . . . . . . . . 6 Electric Heat Data . . . . . . . . . . . . . . . . . . . . . . . . 18 Cabinets and Service Access . . . . . . . . . . . . . . . . 7 Quiet Blower and Motor...

 Open the catalog to page 2
Destiny® Indoor Air Handler-3

rDAI KIN Features and Benefits Horizontal ConfigurationVertical Configuration J Motor Options • Adjustable motor mount simplifies belt tightening • Drive side is field interchangeable to avoid clearance restrictions • Voltage choices • Motor power connection through external junction box • Standard, high, and premium efficiency options • VFD, starter, and disconnect motor control options i2 fc Centrifugal Blower • Minimum turbulence for quiet, efficient operation • Allows higher static pressure operation than blower coil for flexible ducting and unit placement (up to 3" wg total) • Flex collar...

 Open the catalog to page 3
Destiny® Indoor Air Handler-4

rDAI KIN Features and Benefits Hinged Tool Access Panel with Quarter-Turn Handle 18 Access Panels on Both Sides of Each Section • Provide complete easy access to the unit interior • Pocket pull handles to simplify removal and handling of access panels • Optional hinged and quarter-turn latched access doors. • Optional bottom filter access for horizontal units i9Mixing Box Sections • Provide superior mixing of return and outside air streams in ducted return applications • Optional factory mounted actuator and damper linkage to reduce field labor jo| Starter/Disconnects • Factory mounted and wired...

 Open the catalog to page 4
Destiny® Indoor Air Handler-5

rDAI KIN Features and Benefits The Destiny Advantage The Daikin Destiny air handler is a full featured, light air handler that provides a single, economical solution for blower coil and low pressure air handler applications from 600 to 15,000 cfm. Destiny air handlers include many features that make it a superior choice over blower coils and other low pressure air handlers, including: • Double-wall construction with foam injected insulation for durable construction, easy cleaning and superior IAQ • Internally isolated FC fan and motor assembly with a flex collar on the fan discharge for low vibration...

 Open the catalog to page 5
Destiny® Indoor Air Handler-6

rDAI KIN Features and Benefits rDAI KIN Features and Benefits Double-Wall Construction Variable Frequency Drive (VFD) A VFD provides adjustable speed control of a single fan motor. Factory mounted outside the fan door (Figure 3), the VFD provides a lower cost than field installation. A fast-blow fused disconnect (supplied by Daikin or provided by others) is required upstream of the drive. Figure 3: Variable Frequency Drive Electric Heat Option An optional electric heat section (Figure 4, sizes 002 - 010) is available at the discharge end of the Destiny air handler to provide reheat in a horizontal...

 Open the catalog to page 6
Destiny® Indoor Air Handler-7

rDAI KIN Features and Benefits rDAI KIN Features and Benefits Cabinets and Service Access The cabinet interior and components are easily accessed by removing the screws holding the double wall panels in place. Unique pocket pull handles are included in alternate sections to provide sufficient grip to easily remove the panel. Optional tool access hinged doors provide access without having to remove screws. An optional bottom filter access door (Figure 6) provides easy ceiling-mounted unit filter service. Figure 6: Bottom Filter Access Door Quiet Blower and Motor Assembly Destiny air handlers are...

 Open the catalog to page 7
Destiny® Indoor Air Handler-8

Application Considerations Application Considerations Whether units are floor or ceiling mounted, take care to keep the supporting structure level and rigid enough for satisfactory unit operation. Ideally, a heavy concrete slab should be used for floor mounted units and main support beams for ceiling supported hung units. Trapeze ceiling suspended units from field-supplied materials. Avoid long floor or ceiling spans. Good ductwork layout minimizes system resistance and sound generation. Duct connections to and from units should allow straight, smooth airflow. Avoid sharp turns in the fan discharge,...

 Open the catalog to page 8
Destiny® Indoor Air Handler-9

rDAI KIN Application Considerations Piping and Drain Pan Traps When installing piping and drain pan traps: • Install piping in accordance with accepted industry standards. • Do not apply undue stress at the connection to coil headers. • Support pipe work independently of the coils with adequate piping flexibility for thermal expansion. • Run drain lines and traps full size from the drain pan connection. • Drain pans should have traps to permit the condensate from the coils to drain freely. • On a draw-through unit, the trap depth and the distance between the trap outlet and drain pan outlet should...

 Open the catalog to page 9
Destiny® Indoor Air Handler-10

rDAI KIN Application Considerations rDAI KIN Application Considerations Table 1: Temperature and Altitude Conversion Factors * Values are given for reference only. Actual unit capacity must be verified with the Daikin Tools™ selection software. System static pressure and brake horsepower are directly proportional to the air density: sp2 = sp, (density,) (ipm) density, rpm, Consequently, the static pressure and brake horsepower decrease with an increase in air temperature or higher altitude, and increase with a decrease in air temperature or lower altitude. To determine fan performance for temperatures...

 Open the catalog to page 10
Destiny® Indoor Air Handler-11

rDAI KIN Physical Data Note: ‘Ventilation only 11 CAT 580-8 • DESTINY INDOOR AIR HANDLERS

 Open the catalog to page 11
Destiny® Indoor Air Handler-12

rDAI KIN Physical Data Table 5: Base Unit Cabinet Weights—Horizontal Unit with Plenum Fan CAT 580-8 • DESTINY INDOOR AIR HANDLERS 12 www.DaikinApplied.com

 Open the catalog to page 12
Destiny® Indoor Air Handler-13

rDAI KIN Physical Data Table 8: Motor Weights*** Note: * 56/56H frame and 5/8" shaft diameter for 1-ph motors 143T frame and 7/8" shaft diameter for 3-ph motors ** 56/56H frame and 5/8" shaft diameter for 1-ph motors 143T frame and 7/8" shaft diameter for 3-ph motors *** Refer to “HP range” in Table 13 on page 16 for applicable motors per unit size

 Open the catalog to page 13

All Daikin Applied catalogs and technical brochures

  1. PreciseLine®

    4  Pages

  2. OptiLine™

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.