Product catalog summary
Introduction
The Daikin HiLine™ fan-coil units are designed for flexibility and performance, suitable for multi-floor apartments, office buildings, and hotels. They offer efficient, quiet performance with individual thermostatic control, simple installation, and low maintenance costs. Two designs are available: low CFM (300-800 cfm) for individual room control and high CFM (1000-1200 cfm) for multiple discharge arrangements.
Design Features
Units are available in two configurations: blow-through for sizes 03-08 and draw-through for sizes 10-12. The blow-through design features a removable chassis for easy maintenance, while the draw-through design allows for high CFM performance with low sound levels. Both designs support two-pipe and four-pipe systems with various discharge arrangements.
Installation and Configuration
Installation is streamlined with factory-assembled units and riser slip couplings, requiring minimal labor. Twin units can share risers to reduce costs while maintaining individual control. The FHSK knock-down unit allows for riser installation before unit placement.
Performance and Efficiency
High-capacity, low-flow coils are standard, with separate heating coils for four-pipe systems. Coils are designed for high heat transfer efficiency and are AHRI certified. The units feature efficient, quiet fans and motors with three-speed operation.
Optional Features
Factory-installed risers and valve packages are available, with multiple configurations of motorized valves and optional insulation. Units can be equipped with various thermostats for different control options.
Application Considerations
Units are designed for fast, low-cost installation and offer flexibility for different application requirements. They are suitable for both new installations and retrofits, providing a versatile solution for HVAC needs.
Specifications and Features
The document outlines various specifications and optional features for HVAC systems, including valve packages, flow control, and motor options. It highlights the availability of electric heat units, fresh air dampers, and different grille types. Motors are available in 115/60/1 and 277/60/1 configurations, with features like 3-speed operation and automatic reset overload protection.
Installation Procedures
Two installation methods are described: the basic FHSS unit and the knock-down FHSK unit. The FHSS unit is installed directly above the unit on the floor below, while the FHSK unit allows for riser installation and testing before placement. Both units can be integrated into room designs to minimize space usage.
Application Data
The document emphasizes the importance of accurate system design for efficient fan coil systems. Key considerations include temperature settings, ventilation methods, and heating/cooling requirements. It also discusses the selection of unit sizes based on peak load requirements and ventilation needs.
Piping Systems
Two piping systems are detailed: reverse return and direct return. The reverse return system is self-balancing, while the direct return system requires individual unit balancing. The document also addresses pipe expansion and contraction, recommending methods to accommodate these changes.
Performance Data
Performance tables provide cooling and heating capacity ratings for different unit sizes, based on specific conditions. The document advises using the DaikinTools™ program for precise unit selection.
Additional Considerations
The document covers contractor responsibilities, including the installation of riser couplings and insulation. It also discusses temperature control options and the benefits of twin unit designs for cost efficiency.
Engineering Guide Specifications
Model FHSK (Knock-down Unit)
Specifications
The document outlines the specifications for Daikin's HiLine fan coil units, specifically model FHSK, which are designed for low cfm applications. The units are available in sizes ranging from 03 to 08 (300 to 800 cfm). The units are configurable as either two-pipe or four-pipe systems with a blow-through configuration and a removable chassis for easy access to internal components.
Cabinet and Components
The cabinet is made of heavy-gauge galvanized steel, fully insulated, and includes a sound baffle panel. The return air grille is made of heavy-gauge steel with a semi-gloss finish. Coils are AHRI certified, made of seamless copper tubes with aluminum fins, and include manual air vents. The fan assembly varies by unit size, with fan wheels being dynamically balanced.
Optional Features
Several optional features are available, including discharge grilles, line-of-sight baffles, fresh air dampers, electric heating elements, and twin unit configurations. Controls and valves can be customized for two-pipe or four-pipe systems.
Control Systems
Units can be controlled via a wall-mounted or unit-mounted thermostat, with wiring provided for easy installation. A 10K thermistor is included for temperature control.
Warranty and Services
Daikin equipment is sold with a Limited Product Warranty. For warranty details, customers are advised to consult their local Daikin Representative. Aftermarket services and parts are available through Daikin's website or customer service numbers.
Additional Information
The document emphasizes the importance of proper care and training for Daikin equipment, directing users to Daikin's training resources. The document also notes that all products are manufactured in an ISO Certified Facility.
See more

Catalog excerpts

CAT 770-15 HiLine Vertical Stacking Fan Coil Units-1

HiLine™ Vertical Stacking Fan Coils Type FHSS and FHSK Engineered for flexibility and performance™

 Open the catalog to page 1
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-2

Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Daikin HiLine™ fan-coil units . . . . . . . . . . . . . . . . . . 3 . Model FHSS (Basic Unit) Sizes 03 Thru 08 (300 thru 800 cfm) . . . . . . . . . . . . 18 Low CFM design (300 thru 800 cfm) . . . . . . . . . . . . 4 High CFM design (1000 thru 1200 cfm) . . . . . . . . . . 5 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 6 Design features for high performance and low operating cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Optional features and accessories...

 Open the catalog to page 2
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-3

Introduction Daikin HiLine™ fan-coil units . The Daikin HiLine fan-coil air conditioning units are designed for use in multiple floor apartments, office buildings, hotels and other similar applications and require a minimum amount of floor space. Just one HiLine unit may do the job that formerly required more than one conventional unit . The results of many years of experience in the development, design and manufacture of fan-coil air conditioners have been incorporated in the Daikin HiLine units to provide highly efficient, quiet performance; individual thermostatic control; simple, low cost...

 Open the catalog to page 3
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-4

Introduction Low CFM design (300 thru 800 cfm) Blow-through units to meet individual room requirements Neutral unit shown (risers in back) FAST, SIMPLE INSTALLATION Simply stack one unit above the other, sweat the couplings to the risers and connect the power. The unique nonstop slip couplings require only one person for setting and connecting. Low Sound Level Operation - The low cfm design features a quiet, energy efficient motor and fan assembly, carefully located within a fully insulated cabinet to provide low sound level operation. RISERS - Factory cut 104" long. No on-thejob cutting required....

 Open the catalog to page 4
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-5

Introduction High CFM design (1000 thru 1200 cfm) For Multiple Discharge Arrangements Specially Designed For High CFM Performance - these draw-through type units are ideal for luxury hotel and condominium type buildings where multiple discharge arrangements with a common return air location, high cfm performance and quiet operation are required. Neutral unit shown (risers in back) Fast, Simple Installation -Simply stack one unit above the other, sweat the couplings to the risers and connect the power. The unique non-stop slip couplings require only one person for setting and connecting. Risers...

 Open the catalog to page 5
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-6

Features and Benefits Design features for high performance and low operating cost Telescoping Thermostat Box Unit configuration Unit sizes 03 through 08 feature a blow-through design with completely removable chassis. The motor, fan assembly, coil(s), drain pan and valve packages are mounted on a compact chassis which slides out through the return air grille and access panel. Unit sizes 10 and 12 feature a draw-through design. Filter, drain pan and drain line are accessible by removing the return air grille. Controls, valves, motor and fan assembly are accessible by removing the access panel....

 Open the catalog to page 6
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-7

Features and Benefits Coils Efficient, quiet fans and motors High-capacity, low-flow heating/cooling coils are standard. Separate row heating coils are available for 4-pipe systems. All coils are furnished with manual air vents. Three-speed, permanent split capacitor motors coupled with DWDI forward curved direct drive fans provide efficient operation. Motors have sleeve bearings, oilers and inherent automatic reset thermal overload protection. Unit sizes 03 through 04 have a two-piece fan housing with integral scroll and inlet. Unit sizes 06 through 12 have a heavy-gauge steel fan housing with...

 Open the catalog to page 7
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-8

Features and Benefits Factory- and field-installed risers Riser, Slip Coupling and Insulation Insulated risers are available factory-installed or can be shipped with or prior to the units for field installation (factory installed risers are not available for FHSK knock-down units). See details below. On 03 through 08 units, sweat ball valves are included with factory risers. All copper risers are factory cut to 104" in length. Nonstop slip couplings for supply and return risers and stop type couplings for drain risers may be ordered separately. Insulation meets or exceeds current flammability...

 Open the catalog to page 8
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-9

Features and Benefits Optional features and accessories Electric Heat Motors 115/60/1 and 277/60/1 motors are available. All motors are 3-speed permanent split capacitor type with sleeve bearings, oilers, resilient mounts and automatic reset internal overload protection. Electric heat A specially designed, optional electric heat unit is available for supplementary heat between seasons or to provide full electric heating. All heaters are protected by automatic-reset, high-limit thermal cutouts. Service access to electric heaters is through the return air grille and access panel for unit sizes...

 Open the catalog to page 9
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-10

Features and Benefits Installing The FHSS (Basic) Unit: 1. The Daikin HiLine basic unit is simply lifted into place directly above the unit on the floor below. 2. This unit has been set in place, ready to accept the unit above. 3. Next, using factory available slip couplings, connect the prefabricated supply, return and drain risers together, connect the power, and your basic installation is completed. Wall board can be applied directly to the unit. 4. After the unit has been “furredin” and the room painted, it takes only a few minutes to attach the grilles and plug in the thermostat. 5. When...

 Open the catalog to page 10
CAT 770-15 HiLine Vertical Stacking Fan Coil Units-11

Application Data Application considerations System design The achievement of an efficient fan coil system is dependent upon accurate system design and proper equipment selection. Variations, limitations and control of fan coil systems, design conditions and design load calculations are not described in detail in this catalog. More detailed information may be found in the ASHRAE Handbook series. Prior to selecting the individual unit sizes, the design engineer must fix or determine the following factors: 1. Inside and outside wet and dry bulb temperatures. 2. Method of introducing the ventilation....

 Open the catalog to page 11

All Daikin Applied catalogs and technical brochures

  1. PreciseLine®

    4  Pages

  2. OptiLine™

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.