1. Catalogs
  2. Daikin Applied
  3. CAT 735-9 Large Capacity Horizontal Fan Coils

CAT 735-9 Large Capacity Horizontal Fan Coils

CAT 735-9 Large Capacity Horizontal Fan Coils
1 / 30 PagesView full catalog

CAT 735-9 Large Capacity Horizontal Fan Coils

Product catalog summary
Overview
The catalog details large capacity fan coil units, including belt-drive and direct-drive models, available in cabinet and hideaway configurations. These units are designed for flexibility and performance, suitable for concealed ceiling locations and exposed ceiling suspension.
Nomenclature
This section explains the coding system for identifying unit types, product identifiers, design series, voltage options, and unit sizes. For example, 'HC' denotes a horizontal large capacity unit with a cabinet, while 'HH' indicates a unit without a cabinet.
Advantages
The fan coil units combine cooling, heating, humidity control, and filtering in a compact unit. They are economical, easy to maintain, and provide quiet operation. The units offer multiple configurations and options for engineers, fast delivery, and simple installation for contractors.
Features
Constructed with heavy gauge galvanized steel, the units include multi-speed motors, insulated casings, and various coil options. Direct-drive units have large diameter centrifugal fans and PSC motors for quiet operation, while belt-drive units handle higher flow rates and offer performance flexibility.
Accessories and Options
Optional accessories include secondary reheat coils, stainless steel drain pans, and various filtration options. Units can be customized with different cabinet colors and motor voltages.
Engineering Guide Specification
The catalog provides detailed specifications for engineering purposes, ensuring units meet safety and performance standards, including UL safety listings.
Specifications
Coils are made from seamless copper tubing with aluminum fins, available in 3- and 6-row configurations. Drain pans are galvanized steel with optional stainless steel versions. Fans are centrifugal, balanced for smooth operation, and motors are belt-duty, adjustable for tensioning.
Procedures
Installation and maintenance are facilitated by removable panels. The return air plenum is designed for easy duct connections and is insulated. Filters are disposable and easily accessible.
Accessories
Optional features include secondary drain pans, stainless steel pans, extended drain pans, double deflection grilles, and duct collar kits. Four-pipe systems can include factory-installed reheat coils.
Valve and Piping Packages
Three preassembled packages are available for field installation, offering basic, enhanced, and deluxe options with varying levels of control and measurement capabilities.
Unit Selection
Guidelines for selecting unit sizes based on peak load requirements and operating conditions are provided. Cooling and heating capacities are detailed for different coil types and configurations.
Coil Capacities
Tables provide detailed ratings for water cooling and heating capacities, including flow rates and pressure drops for various unit sizes and configurations.
Steam Heating Coil Conversion Factors
A table provides conversion factors for steam heating coil capacities at various steam pressures and entering air temperatures.
Airflow Capacities
Tables detail the airflow capacities of direct-drive and belt-drive units at different external static pressures.
Pressure Drop through Components
This section includes a table showing the static pressure drop across different components for various airflow rates.
Fan Performance
Fan performance data, including RPM and brake horsepower for different static pressures, is provided.
Physical and Dimensional Data
Dimensional data for direct-drive cabinet and hideaway units are provided, including knockout dimensions for coil connections.
Filter Specifications
The filter section includes 2-inch flat type filters available in MERV 3 throwaway, MERV 8 pleated, or MERV 13 pleated types.
Installation Procedures
Installation should follow the manufacturer's Installation & Maintenance instructions.
Product Information
Daikin offers a range of products including ThinLine™ Fan-coils, Large Capacity Fan-coils, Unit Heaters, and HiLine™ Fan-coils.
Training and Development
Daikin provides training for all HVAC products.
Warranty and Aftermarket Services
All equipment is sold under standard terms and conditions, including a Limited Product Warranty.
See more

Catalog excerpts

CAT 735-9 Large Capacity Horizontal Fan Coils-1

Large Capacity Fan Coil Units Belt-Drive and Direct-Drive Cabinet and Hideaway Models Engineered for flexibility and performance™

 Open the catalog to page 1
CAT 735-9 Large Capacity Horizontal Fan Coils-2

Table of Contents Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Valve and Piping Packages . . . . . . . . . . . . . . . . . . . 11 Physical and Dimensional Data . . . . . . . . . . . . . . . . 21 Engineering Guide Specification . . . . . . . . . . . . . . 26 Agency Listing

 Open the catalog to page 2
CAT 735-9 Large Capacity Horizontal Fan Coils-3

Belt-Drive Hideaway Unit (HHBB) Direct-Drive Hideaway Unit (HHDB) Direct-Drive/Belt-Drive Cabinet Ceiling Unit (HCDB/HCBB) HC Unit Type HC = Horizontal Large Capacity with Cabinet HH = Horizontal Large Capacity without Cabinet Product Identifier BB = Belt-Drive Blow-through DB = Direct-Drive Blow-through Design Series 1 = Vintage A A Voltage A = 115/60/1 C = 208/60/1 D = 208/60/3 G = 230/60/1 H = 230/60/3 J = 265-277/60/1 K = 460/60/3 L = 575/60/3 V = 277/60/1 Unit Size 06 = 600 cfm 08 = 800 cfm 12 = 1200 cfm 18 = 1800 cfm 20 = 2000 cfm 30 = 3000 cfm

 Open the catalog to page 3
CAT 735-9 Large Capacity Horizontal Fan Coils-4

Overview Direct-Drive Hideaway Unit (HHDB) Belt-Drive Hideaway Unit (HHBB) The Direct-drive hideaway unit is designed for installation in a fully concealed ceiling location. These units will deliver desired air flows against a wide range of external static pressures associated with varying duct layouts. Unit features include: Belt-drive units offer 5 unit sizes from 800 to 3000 nominal CFM. The Belt-drive hideaway unit is designed for installation in a fully concealed ceiling location. These units incorporate most of the money-saving installation features of smaller Direct-drive fan coils, and...

 Open the catalog to page 4
CAT 735-9 Large Capacity Horizontal Fan Coils-5

Advantages The Large Capacity Advantage Large Capacity fan coil units combine cooling, heating, humidity control and filtering functions in a single compact unit expanding limitations usually associated with fan coil applications. These features make Large Caps desirable by building owners, specifying engineers, and contractors alike. For contractors, Large Capacity fan coils offer a stock program for fast delivery and a number of factory- and fieldinstalled features, making installation fast and simple. By using Large Capacity Fan Coils, building owners have an economical option, with features...

 Open the catalog to page 5
CAT 735-9 Large Capacity Horizontal Fan Coils-6

Features Hideaway and Cabinet Direct-Drive Units (HHDB & HCDB) Hideaway type and cabinet type Large Capacity fan coil units are available for concealed installations or ceiling suspension within the conditioned space. Cooling, heating, dehumidifying and air filtering are combined in a single, compact unit. A full line of optional accessories makes these units completely versatile in application. Large Capacity fan coil units are designed to deliver the rated capacity against normal external static pressures, and may be installed for either “free” or “ducted” air delivery. Large diameter direct-drive...

 Open the catalog to page 6
CAT 735-9 Large Capacity Horizontal Fan Coils-7

Features Dependable Trouble-free Performance Standard Features Casing and Cabinet. Frame members and basic casing are constructed of G-60 galvanized steel. Cabinet unit casing is fabricated of G-60 galvanized steel with 1” thick neoprene coated fiberglass internal insulation. Internal insulation not only protects from sweating and corrosion but also serves as sound absorbing acoustic barrier. Side and bottom panels are removable for ease of installation and maintenance. Cabinet units are painted a standard Antique Ivory, optional colors include: Cupola White, Off White, Putty Beige, Soft Gray...

 Open the catalog to page 7
CAT 735-9 Large Capacity Horizontal Fan Coils-8

Features Hideaway and Cabinet Belt-Drive Units (HHBB & HCBB) Higher Static and Flow Rates Designed to handle higher flow rates than direct-drive units, belt-drive hideaway and cabinet type Large Capacity fan coils are available for concealed installations or ceiling suspension within the air conditioned space. Cooling, heating, dehumidifying and air filtering are combined in a single, compact unit. A full line of optional accessories makes these units completely versatile in application. Properly matched components, high quality galvanized heavy gauge steel construction, and thorough testing...

 Open the catalog to page 8
CAT 735-9 Large Capacity Horizontal Fan Coils-9

Features Heavy Construction for Exceptional Reliability Standard Features Casing and Cabinet. Frame members and basic casing are constructed of G-60 galvanized steel. Cabinet unit casing is fabricated of G-60 galvanized steel with 1" thick neoprene coated fiberglass internal insulation. Internal insulation not only protects from sweating and corrosion but also serves as sound absorbing acoustic barrier. Cabinet units are painted in a standard Antique Ivory. Other optional colors are available such as: Cupola White, Off White, Putty Beige, Soft Gray or Oxford Brown. Custom colors are available...

 Open the catalog to page 9
CAT 735-9 Large Capacity Horizontal Fan Coils-10

Accessories Accessories for Field or Factory Installation Optional Features for Application Flexibility Secondary Drain Pan for Hideaway Units. A secondary drain pan to collect condensate from valves and piping manifolds is available for field mounting. Stainless Steel Drain and Drip Pans. Optional SS secondary drain and drip pans are available (factory installation only). SS pan is equipped with ¾" secondary copper drain connection. Extended Secondary Drain Pan for Cabinet Units. Available for collecting condensate from valve piping, valve packages, piping, and piping manifolds inside cabinet...

 Open the catalog to page 10
CAT 735-9 Large Capacity Horizontal Fan Coils-11

Valve and Piping Packages Valve and Piping Packages (For Field Installation Only) Three factory preassembled Valve & Piping packages for simple field installation are available for both two and four-pipe systems for either right or left-hand connections. Packages are shipped loose with the unit. 2-way or 3-way valves are available with line or low-voltage actuators. • Basic Package: Interconnecting copper adapters and shutoff ball valves for supply and return lines, and control valve on supply water pipe complete with stainless steel flexible hoses. • Enhanced Package: Enhanced valve and piping...

 Open the catalog to page 11
CAT 735-9 Large Capacity Horizontal Fan Coils-12

Unit Selection The achievement of an efficient fan coil system is dependent upon accurate system design and proper equipment selection. Variations, limitations and control of fan coil systems, design conditions and design load calculations are not described in detail in this catalog. More detailed information may be found in the ASHRAE Guide, from which the design engineer can mike initial unit selections to meet the requirements of the system. The initial unit selection should be checked for air volume in the design system, and the cooling capacities checked at the actual operating conditions....

 Open the catalog to page 12

All Daikin Applied catalogs and technical brochures

  1. PreciseLine®

    4  Pages

  2. OptiLine™

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.