1. Catalogs
  2. DAGARD
  3. Fire protection
video corpo

Fire protection

Fire protection

Fire protection

Product catalog summary
Overview: The LF panel is a mineral wool core sandwich panel designed for industrial operations, providing fire protection while maintaining thermal insulation. It is suitable for both new constructions and renovations, offering flexibility in building layouts and compliance with insurance and design specifications.
Applications: The panel is non-combustible and available in various thicknesses, making it ideal for insulating cladding, interior walls, ceilings, and isothermal partition walls. It supports both vertical and horizontal mounting, with hygienic finishes that facilitate cleaning.
Characteristics: The panel features a high-density rock wool core bonded between steel sheets with polyurethane glue. It offers different volumetric masses and thermal conductivities, with standard thicknesses ranging from 40 mm to 240 mm. The panels are designed for easy installation with an interlock snap-on system.
Coating Options: Standard panels come with a polyester powder-coated galvanized steel finish, with options for environments requiring high hygiene or intensive cleaning, such as brushed PET, PVDF, antibacterial PVC, and stainless steel.
Fire and Safety Standards: The LF panel is classified as A2-s1,d0 for fire behavior and complies with CE marking standards (NF NE 14509). It has received approvals from Factory Mutual and CSTB.
Dimensions: The panels have a module width of 1160 mm and a maximum length of 12 meters, depending on thickness.
Additional Features: Various sealing and finish solutions are available for joints, and the panel is suitable for both vertical and horizontal mounting. Notable installations include Roissy Charles de Gaulle Airport and facilities for companies like Nestlé and Danone.
See more

Catalog excerpts

Fire protection-1

LF panel The LF panel is an insulated mineral wool core sandwich panel for industrial operations to meet fire conditions while retaining thermal insulation characteristics. The protection of people and assets is within its remit, it easily fits in with the layout of buildings while meeting insurance and design office specifications. Fire Protection Cladding panels : mounting vertically or horizontally Application The LF panel with its high density mineral wool core and its overlap profile is non combustible. Its various thicknesses make it ideal for the construction of new buildings, for new layouts in existing premises or for insulating cladding. When used as a lining panel (thickness 40 mm), it clads interior walls or ceilings to enable business premises or dilapidated spaces to meet sanitary standards. With thicknesses from 60 to 160 mm, it is used for the realization of isothermal partition walls or bearing ceilings in positive temperature areas. Rounded junctions as reflex angles, flush finishes with concealed screws, ensure hygienic conditions and good lines while facilitating cleaning. Characteristics Coating The selection of panel faces must be appropriate to the utilization of the premises and of their surrounding environment. The standard product is a polyester powder-coated galvanized steel plate Iceberg white (near RAL 9010), slightly corrugated (depth of rib 0.6 mm) or smooth. For specific ambient conditions (high level of hygrometry, intensive cleaning...), other panel faces are available: brushed PET 55, PVDF, antibacterial PVC 150 μ, stainless steel with PVC + PET film... They are covered with a protective film that should be removed

 Open the catalog to page 1
Fire protection-2

Characteristics Insulating core The LF panel is made up of a high density insulating rock wool core set, using a press, between two steel sheets with a polymerized bi-component polyurethane glue. Volumetric mass : 135 kg/m3, 120 kg/m3, 100 Kg/m3 Thermal conductivity : 0,041 W/m.K. The thickness of panels is selected according to the temperatures required for the work or storage spaces. Standard thicknesses* (mm) Weight (kg/m²) 2 sides 5/10e density 100 kg/m3 Values of Uc (W/m².K) and R (m².K/W) λ at + 10°C = 0,041 W/m.K Uc in wall Dimensions Width : module 1160 mm Length maxi 12 m (according...

 Open the catalog to page 2

All DAGARD catalogs and technical brochures

  1. Toundra

    4  Pages

  2. OPTIMA

    4  Pages

  3. Cleanrooms

    12  Pages

  4. Doors

    2  Pages

  5. Access ramp

    2  Pages

  6. Valves

    2  Pages

  7. Europa

    4  Pages

Archived catalogs

  1. Toundra cell

    4  Pages

  2. Optima

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.