Doors
2Pages

{{requestButtons}}

Catalog excerpts

Doors - 1

Hinged door Doors play a very important part in any installation. They need to be resistant to constant opening and closing, to aggressive surrounding environments, to often hard cleaning conditions and to blows caused by passing trolleys and trucks. They meet the stringent resistance and insulation criteria required by industrial cold storage or retail trade areas of activity. Dagard offers doors with facings in smooth polyester 25 µm lacquered galvanised steel sheet iceberg white (close to RAL 9010) But also in facings PVDF lacquer, stainless steel, PET, PVC 120µ, GRP (Glass Reinforced Polyester), stainless steel+PVC+PET, polyethylene. Hardware have been selected for their resistance in intensive uses. To contribute to the longevity of your realizations, the follow-up of these parts is assured during many years. Designed for warehouses, processing shops and providing a through way for personnel, it is used both inside and outside in positive and negative temperature environments. Injected polyurethane foam insulation Lacquered aluminum monobloc doorframe. Thickness 60 mm for positive temp. Thickness 120 mm for negative temp. Dimensions: from 850 x 620mm to 2200 x 1500mm Options - guard at base of door - panic bar kit - rack opening - oculus for positive temperature - canopy - organization chart - stainless steel frame - reinforced edges - ... Alpha 200 sliding door During the construction of an isothermal enclosure in sandwich panels, several criteria are to be taken into account for the choice of doors. Type of door and passageways Clear opening Thermal insulation Used inside, designed for positive temperature, it is economic, simple, convenient and effective. It is provide of PVC inside cleanliness plate. Injected polyurethane foam insulation Sheet steel monobloc doorframe Thickness 60 mm for positive temp. Dim. from 1850 x 800 mm to 2200 x 1600 mm Options - key lock in wall lamp with inside unlocking of the lock - opening from outside and/or inside with lever handle - protective tube at bas - organization chart - ... Panel face / environment The type of door and its mode of opening must be appropriate to the layout of premises and the use. The doors possess different insulation characteristics. The appropriateness of the type of door must be checked against the constraints of the planned utilization. In cases where the enclosure has to meet specific fire regulations, the door must be selected according to criteria of fire reaction or fire resistance. In order to customize, to identify your work spaces, to make units more attractive, the colour of leaves can be selected on the colour chart. (non contractual colour chart). Colour chart In order to determine the required dimensions of doors, it is important to check on the use planned for the clear opening (throughway for people, goods and equipment). The type of panel face will be selected depending on the surrounding environment and on whether the door will be used intensively or not. Specific utilizations, options Alpha 500 sliding door Used inside or outside, it provides a through way for personnel and smaller types of trucks. It resists to shocks and stains thanks to its stainless steel outside protection and its PVC inside cleanliness plate. Injected polyurethane foam insulation. Lacquered aluminum monobloc doorframe Thickness 60 mm for positive temp. Thickness 120 mm for negative temp. Dimensions: from 1850x950 mm to 2500x2400 mm Polyethylene chart blanc naturel Tough - Functional Efficient - Attractive Options - kick plate at base of door - Surface-mounted key lock with unlocking from inside - rack opening - protective tube at base - electric automatism - organization chart - reinforced edges - version 520 all stainless steel or with sheet steel leaf, non-automatable - ... Ultra 600 sliding door t acts as a throughway for large industrial trucks in spaces where traffic is dense. It uses inside or outside for negative or positive temperatures. Injected polyurethane foam insulation. Lacquered aluminum monobloc doorframe. Thickness 85 mm for positive temp. Thickness 150 mm for negative temp. Dim. 2500 x 1600 mm to 3200 x 3200 mm Options - kick plate at base of door - key lock in wall lamp with inside unlocking of the lock - stainless steel track opening and seating - protective tube at base - electric automatism - organization chart - stainless steel frame - gre

Open the catalog to page 1
Doors - 2

A service door for offices, special purpose areas and work spaces, it is designed as a throughway for personnel and can be installed in spaces where temperatures are similar. One or two leaves. PVC or lacquered aluminium monobloc doorframe Thickness 40 mm Dimensions : 2040x610 mm to 2440x2040 mm Service door DAGfeu fire resistante EI60 These fire resistance performances are guaranteed and answer to fire safety requirements. One or two leaves. Sheet steel monobloc doorframe. Thickness 54 mm Dim. 2000 x 800 mm to 2200 x 2000 mm Polyethylene or sheet Swing door Used to separate premises with...

Open the catalog to page 2

All DAGARD catalogs and technical brochures

  1. Toundra

    4 Pages

  2. OPTIMA

    4 Pages

  3. Cleanrooms

    12 Pages

  4. Access ramp

    2 Pages

  5. Valves

    2 Pages

  6. Europa

    4 Pages

Archived catalogs

  1. Optima

    4 Pages

  2. Toundra cell

    4 Pages