Overview: This document provides technical specifications for AS2 and AS3 indicators used to measure free chlorine and chlorine dioxide in drinking water. It covers applications, electronic configurations, measuring ranges, and maintenance requirements.
Specifications:
  • Application: Suitable for cold and hot drinking water up to 70°C.
  • Chlorination Agents: Compatible with sodium hypochlorite, calcium hypochlorite, chlorine gas, and electrolytically generated chlorine.
  • Measuring System: Uses an amperometric potentiostatic 3-electrode system.
  • Electronic Versions: Available in analog, digital, and mA versions with varying galvanic isolation.
  • Measuring Range: Sensor slope varies from 65% to 150% of the nominal slope.
  • Temperature: AS2 operates from 0 to 50°C, AS3 from 0 to 70°C.
  • Pressure: Maximum pressure is 0.5 bar without a retaining ring and 8 bar with a retaining ring in TARAflow FLC.
Procedures:
  • Calibration: Uses the DPD-1 method for chlorine and chlorine dioxide.
  • Maintenance: Weekly signal control is recommended, with cleaning and electrolyte changes as needed.
Norms and Standards:
  • EMC Tested: Complies with electromagnetic compatibility standards.
  • RoHS Compliant: Materials comply with the Restriction of Hazardous Substances Directive.
Recommendations:
  • Cleaning Equipment RV1: Recommended for AS...-CL to extend maintenance intervals and stabilize signals.
  • Flow Rate: Specifies minimum flow rates for optimal operation.
Accessories and Spare Parts:
  • Includes cleaning equipment, spare hulls, electrolytes, and O-rings with specific part numbers.
Technical Data:
  • Chlorine Measurement: Specifications for analog and digital outputs, measuring ranges, resolutions, and connection types.
  • Chlorine Dioxide Measurement: Similar specifications with variations in measuring ranges and outputs.
Technical Document Summary:
1. Specifications: Details for sensor models AS2MA1-CD-M12, AS2MA2-CD-M12, AS2MA5-CD-M12, AS3MA1-CD-M12, AS3MA2-CD-M12, AS3MA5-CD-M12, and AS3MA20-CD-M12, including measuring range, resolution, and output in mA/ppm.
2. Electrical Connection: Sensors use a 5-pole M12 plug-on flange with specified wire functions.
3. Graphical Data: Includes graphs showing sensor dependence on pH values and flow rate.
4. Notes: Document is subject to technical changes, dated January 2025, version 15.
See more

Catalog excerpts

DABECO AS2 Free Chlorine Sensor-4

- direct installation on the sensor - approaching flow to the sensor through RV1 - cleaning effect of RV1 is moderate, i. e. weak deposits on the electrodes will be removed, e. g. weak rust films - for a correct and proper operation of sensor with cleaning equipment RV1 flow chamber FLC-3 has to be used!! - Sensor can be upgraded at any time - Using with AS...-CL: => slope is approx. 3 times higher (see diagram “AS-Chlorine Sensor with and without RV1”) - Using with AS...-CD: => slope is approx. 2 times higher (Subject to technical changes.) (Subject to technical changes.)

 Open the catalog to page 4
DABECO AS2 Free Chlorine Sensor-5

January 2025 (EN) V15 Technical Data A) Chlorine 1. AS - CL (analog output, analog internal signal processing) Galvanic isolation required in the measuring device/controller * PIN1: measuring signal PIN2: +U PIN3: power GND PIN4: signal GND PIN5: n. c. PIN1: measuring signal PIN2: +U PIN3: power GND PIN4: signal GND PIN5: n. c.

 Open the catalog to page 5
DABECO AS2 Free Chlorine Sensor-6

(Subject to technical changes!)

 Open the catalog to page 6
DABECO AS2 Free Chlorine Sensor-7

(Subject to technical changes!)

 Open the catalog to page 7
DABECO AS2 Free Chlorine Sensor-8

4. AS - CL 4-20 mA (analog output, analog internal signal processing)4.1 Electrical connection: 2 pole terminal clamp Measuring range Output resistance Voltage supply Galvanic isolation required in the measuring device/controller * Recommended: Round cable 0 4 mm 2 x 0.34 mm2 (Subject to technical changes!)

 Open the catalog to page 8
DABECO AS2 Free Chlorine Sensor-9

4.2 Electrical connection: 5 pole M12 plug-on flange (Subject to technical changes!)

 Open the catalog to page 9
DABECO AS2 Free Chlorine Sensor-10

B) Chlorine Dioxide1. AS - CD (analog output, analog internal signal processing) Galvanic isolation required in the measuring device/controller * PIN1: measuring signal PIN2: +U PIN3: power GND PIN4: signal GND PIN5: n. c. PIN1: measuring signal PIN2: +U PIN3: power GND PIN4: signal GND PIN5: n. c. (Subject to technical changes!)

 Open the catalog to page 10
DABECO AS2 Free Chlorine Sensor-11

(Subject to technical changes!)

 Open the catalog to page 11
DABECO AS2 Free Chlorine Sensor-12

(Subject to technical changes!)

 Open the catalog to page 12
DABECO AS2 Free Chlorine Sensor-13

4.1 Electrical connection: 2 pole terminal clamp (Subject to technical changes!)

 Open the catalog to page 13
DABECO AS2 Free Chlorine Sensor-14

4.2 Electrical connection: 5 pole M12 plug-on flange (Subject to technical changes!)

 Open the catalog to page 14
DABECO AS2 Free Chlorine Sensor-15

Data Sheet January 2025 (EN) V15 AS-Sensoren, relative pH-Abhängigkeit AS-sensors, relative dependence on pH Cl2

 Open the catalog to page 15
DABECO AS2 Free Chlorine Sensor-16

Data Sheet January 2025 (EN) V15 Sensor AS2 / AS3 Abhängigkeit vom Durchfluß, Dependence on the flow rate Durchflussarmatur, Flow Chamber: PEF1/E or Durchflußmenge, Flow rate (Liter/hours) (Subject to technical changes.)

 Open the catalog to page 16

Archived catalogs

  1. W501

    2  Pages

  2. W501-DCCF1.0

    2  Pages

  3. W501-DCD10.1

    2  Pages

  4. W501-DCP4.0

    2  Pages

  5. W501-DOZ10.1

    2  Pages

  6. W501-DP10.1

    2  Pages

  7. W501-DWP10.1

    2  Pages

  8. W510-DCCF1.0

    2  Pages

  9. W771-DCS4

    2  Pages

  10. W771-DCP4.0

    2  Pages

  11. W771-DAS2

    2  Pages

  12. W771-DCC1

    2  Pages

  13. W771-DCL2.2

    2  Pages

  14. W771-DCD-4.2

    2  Pages

  15. W761-DAS2

    2  Pages

  16. W761-DCC1

    2  Pages

  17. W761-DCL2.2

    2  Pages

  18. W761-DCD-4.2

    2  Pages

  19. W510-DCH10

    2  Pages

  20. W510-DCL4.2

    2  Pages

  21. W510-DAS3

    2  Pages

  22. W501-DCH10

    2  Pages

  23. W501-DCL4.2

    2  Pages

  24. W501-DAS3

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.