video corpo

Vibration-Resistant Weighing Indicator
6Pages

{{requestButtons}}

Catalog excerpts

Vibration-Resistant Weighing Indicator - 1

High Performance Digital Filter Featuring the Newly Developed High-Performance Digital Filter (HPDF) for Environments with Vibration Issues A Weighing Indicator that Can Be Used in an Environment with Vibrations Specifications Analog unit External output components Over 0.15µV/d (d=minimum division) –35mV to +35mV (–7mV/V to +7mV/V) DC5V±5%, 120mA Remote sensing function included Up to 8 load cells (350Ω) can be connected Zero; ±0.02µV/˚C (Typ.) ±0.1µV/˚C (Max.) Span; ±3ppm/˚C (Typ.) ±15ppm/˚C (Max.) 0.005% of F.S. Less than 0.3µVp-p –35mV to +35mV (–7mV/V to +7mV/V) Over 10MΩ Delta-sigma modulation Approx. 16,000,000 999,999d (less than 20,000d recommended) 100 times/sec. Actual load calibration or digital span calibration not using actual load Temperature coefficients Powerful Vibration Cancelling Feature The High-Performance Digital Filter provides high accuracy/high speed weighing in environments with vibration problems. The AD-4410 greatly reduces the costs and maintenance required for anti-vibration equipment since it copes with vibrations without requiring many mechanical measures. What's more, conducting weighing while applying vibrations, once an extremely difficult task, is now possible. The High-Performance Digital Filter only requires one setting. For this reason, optimal settings for vibration cancelling can be found after just a few tries. Nonlinearity Input noise Maximum measurement voltage Input impedance A/D conversion method Internal resolution Display resolution Sampling rate Calibration Weight Control I/O Basic specifications Power source voltage Power consumption Operating temperature and humidity Display elements Measurement data display Status display External dimensions High speed sampling (100 times/second)/high accuracy Panel cut dimensions Dust/water protection Circuits equipped with powerful noise reduction Options OP-03 OP-04 OP-11 Note: Only 1 OP-03 or OP-04 can be attached, when OP is attached 20mA current loop will become unusable. Accurate linear correction function using high-order equations Average holding function Standard included items Instruction manual, 7-pin DIN connector, 8-pin DIN connector, load cell connector, power cable, rubber packing, capacity plate, unit stickers Note: Please prepare an RS-232C connector for standard serial output (ch1). A straight cable will be used when connecting to PC or PLC. Unit: mm Stand dimensions Unit: mm (181) 144 Reliably accurate! Powerful vibration-cancelling function (High Performance Digital Filter) Dimensions Digital unit Can be Calibrated in an Environment with Vibrations Until now, to conduct calibration, sources of vibration had to be completely stopped, or calibration had to be conducted on weekends or holidays when machines are not active. However, even in an environment with vibrations, the AD-4410 can be calibrated at any point, so costs incurred from stopping production or calibrating on weekends or holidays will disappear. Vibration-Resistant Weighing Indicator Standard serial output (ch1) Standard serial output (ch2) Weighing display: 7-segment 6-digit green LED Character height of 14.6mm Polarity display: 1 green LED Situational display: 6 red LEDs Display switchable between net and gross weight Display range: 0 to 999,999d (Select between 1, 2, 5, 10, and 50 for minimum division “d”) Units: Affix a “g”, “kg”, or “t” unit sticker ZERO, STABLE, GROSS, NET, HOLD and a light which can be given a custom function by the user Input sensitivity Zero adjustment range Load cell excitation AD-4410 WEIGHING INDICATOR 0 T ZERO STABLE GROSS NET HOLD TARE F I/ ON/OFF ESC 123 72 ZERO Net/B/G NET GROSS ENTER (118.5) (6) Rear panel C.L./OP 138 +1 0 2- ø5 CONTROL I/O 80 48 RS-232C 137 Even with vibrations, weighing is easy! 67 Fast response! 68 +0.7 0 LOAD CELL A&D Company ,Limited Panel cutout dimensions 70 116 152 50/60Hz 10VA 100 240V Appearance and/or specifications subject to change for improvement without notice. Compr essor …Clearly a Better Value 3-23-14 Higashi-lkebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: 81 (3) 5391-6132 Fax: 81 (3) 5391-6148 http://www.aandd.jp A&D Engineering, Inc. 1756 Automation Parkway, San Jose, CA 95131 U.S.A. Telephone: 1 (408) 263-5333 Fax: 1 (408) 263-0119 A&D Australasia Pty Ltd. 32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA Telephone: 61 (8) 8301-8100 Fax: 61 (8) 8352-7409 A&D Instruments Ltd. Unit 24/26 Blacklands Way Abingdon Business Park, Abingdon, Oxon OX14 1DY UNITED KINGDOM Telephone: 44 (1235) 550420 Fax: 44 (1235) 550485 Ge rman Sales Office Hamburger Straße 30 D-22926 Ahrensburg, GERMANY Telephone: 49 (0) 4102 459230 Fax: 49 (0) 4102 459231 A&D Korea Limited A&D RUS Co., Ltd. Vereyskaya str.17, Moscow, 121357 RUSSIA Telephone: 7 (495) 937-33-44 Fax: 7 (495) 937-55-66 A&D Instruments India Private Limited 509 Udyog Vihar Phase V Gurgaon-122 016, Haryana, INDIA Telephone: 91 (124) 471-5555 Fax: 91 (124) 471-5599 Manhattan Bldg. 8F, 36-2 Yoido-dong, Youngdeungpo-gu, Seoul, KOREA Telephone: 82 (2) 780-4101 Fax: 82 (2) 782-4280 AD4410-ADCC-01-KO1-12801 …Clearly a Better Value http://www.aandd.jp

Open the catalog to page 1
Vibration-Resistant Weighing Indicator - 2

We've Added some Brand-New Functions! The AD-4410 has 3 input points and 3 output points for its control I/O. Users can select what functions to assign to the control I/O. We've put in two new functions: user input and user input/output. User input/output can be used for whatever purpose the user wishes. One could turn on certain output terminals using RS-232C or RS-485 commands, or confirm certain Input/output terminals' display. situations using the front panel's For example, it would be useful in a situation where you want to monitor photosensor input using PC or PLC, but there's no...

Open the catalog to page 2
Vibration-Resistant Weighing Indicator - 3

We've Added some Brand-New Functions! The AD-4410 has 3 input points and 3 output points for its control I/O. Users can select what functions to assign to the control I/O. We've put in two new functions: user input and user input/output. User input/output can be used for whatever purpose the user wishes. One could turn on certain output terminals using RS-232C or RS-485 commands, or confirm certain Input/output terminals' display. situations using the front panel's For example, it would be useful in a situation where you want to monitor photosensor input using PC or PLC, but there's no...

Open the catalog to page 3

All A&D COMPANY catalogs and technical brochures

  1. LC1205-USB

    2 Pages

  2. CMX-USB

    1 Pages

  3. LCC20

    1 Pages

  4. AD-4329A

    4 Pages

  5. AD-4401A

    4 Pages

  6. AD-4402

    6 Pages

  7. AD-4408C

    2 Pages

  8. AD-4410

    6 Pages

  9. AD-4403FP

    4 Pages

  10. AD4413-CW

    2 Pages

  11. AD4412-CW

    6 Pages

  12. AD-4531B

    2 Pages

  13. AD-4530

    2 Pages

  14. LCM13 Series

    2 Pages

Archived catalogs