video corpo

A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances
12Pages

{{requestButtons}}

Catalog excerpts

A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 1

Advanced-Level Analytical/Precision Balances GX-A(E / WP) / GF-A(WP) Series Taking Weighing Precision and Protection to New Heights

Open the catalog to page 1
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 2

Simply Created for Practical Purposes All the innovative technologies built into A&D Apollo are designed to provide functional solutions to the real world problems that users face in laboratories or in factories. Now discover what they are, and understand what precision, protection, performance and productivity really mean to you! Smart SHS® Smart super hybrid sensor (Smart SHS) realizing wide lineup from analytical to high-resolution, high-capacity precision models Select a balance that best suits your purposes and budgets. You have a choice from a diverse array of models with varying...

Open the catalog to page 2
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 3

Protection from static electricity (for the GX-AE series) Antistatic glass panes •• The glass panes of the breeze break are coated with transparent evaporated metal to block static from outside (also applied to the 0.0001 g models of the GX-A/GF-A series). External IR switch The GX-AE series comes standard with a touchless switch to activate the ionizer for a set duration. •••••••• •••••••• Actual values may vary due to differences in the ambient environment, shape of the target object, and amount of static charge. Measurement becomes unstable when the target object is statically charged....

Open the catalog to page 3
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 4

Accuracy and precision management Internal weight (for the GX-AE/GX-A/GX-AWP series) Automatic self calibration (ASC) To ensure accuracy at all times, the balance can be set to calibrate itself automatically using its internal weight either (1) in response to change in ambient temperature to prevent error due to sensitivity drift, (2) at a set interval time, or (3) at predetermined (up to three) times of the day. Internal calibration can also be performed any time with one key press. Internal weight value correction In cases such as where the internal weight value varies over time, it can...

Open the catalog to page 4
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 5

Features effective for specific applications Use in production lines The weight sensor of a high-precision balance will be damaged in a short period if continuously affected by loads with acceleration (impact shocks). This typically occurs in factories where materials are placed roughly by machines or thrown onto balances by operators. In addition, impact shocks can easily shift values and cause errors. The problem is that even if you know the above, it can be difficult to judge whether the level of impact shock is significant enough to necessitate preventive or protective measures to be taken....

Open the catalog to page 5
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 6

Flow rate measurement Flow rate is determined from the weight variation that occurs during a given interval. Many operators time this interval by using a stopwatch. Besides being troublesome and error-prone, this method does not allow precise recording of flow rates that vary from moment to moment because the interval used to divide the weight variation (calculation time) is too long. Alternatively, a PC can be connected to the balance to take the weighing data and perform the calculation. This method enables measurement to be more responsive to flow rate changes by shortening the calculation...

Open the catalog to page 6
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 7

Data management, documentation and compliance User access control (UAC) and key lock to prevent misuse The balance can be password-protected in two ways: The first way is to limit use to authorized individuals (up to 11 including one administrator—the administrator can perform all operations while other users are limited to measurements and calibration*7 only) by setting a password for each user. The second way is to set a password for just the administrator, allowing anyone else to use the balance without entering a password, but for measurements and calibration*7 only. Moreover, upon...

Open the catalog to page 7
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 8

Statistical calculation function (SCF) Various statistical data can be calculated and displayed/output to help analyze measurement results. Tare memory The tare value can be saved in non-volatile memory. When this function is activated, the power-on zero/tare is turned off. Therefore, even if the power supply is interrupted during weigh-in or loss-in-weight measurement (e.g. filling), the net value displayed before the loss of power is restored once the balance is turned on again. Data memory A&D Apollo has a capacity to store up to 200 weighing results + 50 calibration results (all with a...

Open the catalog to page 8
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 9

||||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||||| WinCT-FRD WinCT-FRD enables a PC to simultaneously display the weight and flow rate values transmitted from the balance on a two axis graph so that you can see their changes in real time. The graph can be printed out using a printer or saved as an image file, whereas the recorded data can be saved in CSV or TXT format. WinCT-UFC With WinCT-UFC, you can easily edit UFC setting commands on a PC and send them to a balance/scale that has a UFC function, such as A&D Apollo. All that is...

Open the catalog to page 9
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 10

||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||| Air flow logger Rechargeable battery unit Static eliminator*15 Electrostatic field meter Weighing environment logger Weighing data logger Tweezers for calibration weight Compact printer RS-232C/Ethernet (TCP/IP) converter Remote display Remote controller Electrode unit for ionizer (4 pcs) Main unit cover (5 pcs) Waterproof RS-232C cable (5 m) Foot switch for print Foot switch for re-zero RS-232C/USB converter with cable *15 Power needs to be supplied from an AC adapter. Recommended when A&D...

Open the catalog to page 10
A&D Apollo GX-A(E/WP) & GF-A(WP) series of advanced-level analytical/precision balances - 11

Models Capacity Stabilization time (when set to FAST under a good environment) Minimum weight*ii (typical) ±2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF) Sensitivity drift Accuracy immediately after internal calibration (for the GX-A(WP) series)*iv 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation) 5 times/sec, 10 times/sec or 20 times/sec Operating environment Display refresh rate g (gram), oz (ounce), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode),...

Open the catalog to page 11

All A&D COMPANY catalogs and technical brochures

  1. LC1205-USB

    2 Pages

  2. CMX-USB

    1 Pages

  3. LCC20

    1 Pages

  4. AD-4329A

    4 Pages

  5. AD-4401A

    4 Pages

  6. AD-4402

    6 Pages

  7. AD-4408C

    2 Pages

  8. AD-4410

    6 Pages

  9. AD-4403FP

    4 Pages

  10. AD4413-CW

    2 Pages

  11. AD4412-CW

    6 Pages

  12. AD-4531B

    2 Pages

  13. AD-4530

    2 Pages

  14. LCM13 Series

    2 Pages

Archived catalogs