LMR Plus Electric Fire Pump Controllers Features FPMP Fire Pump Multi-Pack Product Features Common Enclosure Efficient Space Utilization The controllers in an FPMP Multi-Pack are housed within one common enclosure with multiple cells. Each cell contains a specific style of controller. A pressure transducer is installed in the bottom of the enclosure for each individual controller, if required. Floor space can be saved by vertically stacking two controllers in the same structure. This design can save over 50% of the floor space required by installing two conventional controllers. Note: The height of the unit will be a maximum of 90 inches. Mixture of Controller Types Several types of controllers can be incorporated into the FPMP design. This includes Electric, Diesel, Transfer Switch and Limited Service controllers. Compact Package The FPMP provides a unique method of packaging multiple types of controllers in a single housing, reducing overall wiring and installation costs in addition to maximizing space utilization. Several options provide total flexibility in powering the individual units within the FPMP enclosure. The combination of a main disconnect switch and horizontal busbar can power the entire line-up of controllers. This option eliminates the need to feed each controller with its own individual power source. If space is the only consideration, each controller can be wired individually on site. Common Power Supply The design of the FPMP allows for a single power source to be connected to the controller. The power is then distributed throughout the controller to each individual cell. Installation Savings Overall installation costs are reduced due to the design of the FPMP. Electrical installation material costs and installation time are reduced which results in an overall cost savings. Standards & Certification The FPMP Multi-Pack Fire Pump Controllers meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, Factory Mutual, the Canadian Standards Association, New York City building code, CE mark and U.B.C / C.B.C. Seismic requirements, and are built to NFPA 20 standards. Reduced Wiring Costs The FPMP uses horizontal and vertical buss bars to distribute power to individual controller compartments. Because of this design, the amount of materials and wiring that would normally be required for multiple controllers is reduced significantly. Must Be Installed Per Applicable Code and Manufacturers Recommendations Any combination of controllers can be installed within the FPMP. Electric, Diesel and Transfer Switch type controllers can all form part of the compact, easy to install Multi-Pack. The lower horsepower electric and the diesel controllers, can be stacked 2-high within a single structure to maximize pump room real estate. A Typical Fire Pump Multi-Pack Layout Configuration LMR Plus Electric Fire Pump Controller All types can be incorporated into the FPMP configuration Structure width and height (max=90”) varies by horsepower Lower Hp units can be stacked 2-high in a single structure FT Series - Transfer Switch SILENCE ALARM MOTOR TEST POWER ON PUMP RUNNING LOCAL START REMOTE START DELUGE VALVE EMERGENCY START INTERLOCK ON LOW PRESSURE AUTO SHUTDOWN ENABLED PHASE REVERSAL PHASE FAILURE FAIL TO START UNDERVOLTAGE OVERVOLTAGE LOW ROOM TEMPERATURE LOCKED ROTOR TRIP LOW SUCTION PRESSURE SOURCE 2 DISCONNECTED SILENCE ALARM MOTOR TEST DATA PRINT Lower HP units can be housed in a single vertical structure with an electric controller Emergency generator or second utility source types available Transfer switch/controller combination must have a dedicated transfer switch for each controller FD120 Diesel Engine Controller PHASE REVERSAL PHASE FAILURE FAIL TO START UNDERVOLTAGE OVERVOLTAGE LOW ROOM TEMPERATURE LOCKED ROTOR TRIP LOW SUCTION PRESSURE SOURCE 2 DISCONNECTED SILENCE ALARM MOTOR TEST Available Available PHASE REVERSAL PHASE FAILURE FAIL TO START UNDERVOLTAGE OVERVOLTAGE LOW ROOM TEMPERATURE LOCKED ROTOR TRIP LOW SUCTION PRESSURE SOURCE 2 DISCONNECTED LAMP TEST RESET SAVE/EXIT POWER ON PUMP RUNNING LOCAL START REMOTE START DELUGE VALVE EMERGENCY START INTERLOCK ON LOW PRESSURE AUTO SHUTDOWN ENABLED DATA PRINT LAMP TEST Can be any combination of 12VDC and 24VDC controllers Stacking in a single vertical structure with lower Hp electric controllers is possible Two (2) diesel controllers can be stacked in a single structure POWER ON PUMP RUNNING LOCAL START REMOTE START DELUGE VALVE EMERGENCY START INTERLOCK ON LOW PRESSURE AUTO SHUTDOWN ENABLED DATA PRINT LAMP TEST RESET SAVE/EXIT Unit Status L M R Connected Load Connected Main Incoming Power Can be connected directly to individual controllers which eliminates the need for a main switch / lugs - ideal for pump houses Non-Fusible Disconnect Switch, lockable in the ON position, can be supplied to power entire line-up Lugs only (specify size and number of cables) can be supplied to power entire line-up For more information visit: www.chfire.com
Open the catalog to page 1All Cutler-Hammer catalogs and technical brochures
-
FT90 Bid Submittal
13 Pages
-
FDF/FTF20 Bid Submittal (Foam)
18 Pages
-
Booster Pump Controllers
12 Pages
-
DFDAP-M / FDAP-M
5 Pages
-
Jockey Pump Controllers
2 Pages
-
Eaton EPCT Fire
4 Pages
-
Remote Alarm Panels
5 Pages
-
Mining solutions linecard
4 Pages
-
Mining solutions
5 Pages
-
Data center solutions
7 Pages
-
NEMA contactors and starters
154 Pages
-
Motor Control Centers
27 Pages
-
Arc-flash safety solutions
12 Pages
-
FT20 Limited Service
3 Pages
-
Fuses
291 Pages
-
Counters, Timers and Tachometers
130 Pages
-
Vehicle and Commercial Controls
204 Pages
-
Enclosed Control - Product Catalog
541 Pages
-
OEM Product
334 Pages
-
Sensing Solutions
561 Pages
-
Solid-State Motor Control
498 Pages
-
Motor Control and Protection
778 Pages
-
Circuit Protection
705 Pages
-
Residential and Light Commercial
401 Pages
-
Commercial Distribution
710 Pages
-
FDAP-M ELECTRIC
1 Pages
-
XTJP JOCKEY PUMP CONTROLLERS
1 Pages
-
MEDIUM VOLTAGE CONTROLLERS
2 Pages
-
FT90 SOFT START
3 Pages
-
FT60 AUTOTRANSFORMER
3 Pages
-
FT50 PRIMARY RESISTOR
3 Pages
-
FT40 Part Winding
3 Pages
-
FT30 ACROSS-THE-LINE
3 Pages
-
FT20 LIMITED SERVICE
3 Pages
-
FD90 SOFT START
2 Pages
-
FD60 AUTOTRANSFORMER
2 Pages
-
FD50 PRIMARY RESISTOR
2 Pages
-
FD40 PART WINDING
2 Pages
-
FD30 ACROSS-THE-LINE
2 Pages
-
FD20 LIMITED SERVICE
2 Pages
-
DIESEL ENGINE CONTROLLERS
2 Pages
Archived catalogs
-
Booster Pump Controllers
12 Pages