Product catalog summary
Motor Control Centers Overview
Eaton's Motor Control Centers (MCCs) are designed for demanding applications and include products like Freedom, Freedom Arc-Resistant, and Freedom FlashGard. These MCCs are customizable and can be shipped quickly through the FAST program.
Aftermarket Products
Eaton offers aftermarket services for MCCs, providing replacement and add-on units for models since 1935. The MCCs are modular plug-in assemblies enclosed in metal structures for safety.
Product Description
The MCCs feature NEMA electromechanical starters for three-phase applications up to 600 hp, with FlashGard MCCs offering arc flash prevention.
Features and Benefits
MCCs have a modular structure for flexibility, front accessibility for maintenance, and advanced safety features. They support industrial communications with protocols like DeviceNet and Modbus.
Standards and Certifications
Eaton's MCCs are UL listed and meet seismic requirements of the UBC and CBC, offering a complete seismic qualified assemblies package.
Technical Data and Specifications
MCCs are available in various configurations with options for different control and service voltages. The Bid Manager program helps in configuring and pricing MCCs efficiently.
Check Sheets
Check sheets are provided for Freedom, Freedom FlashGard, and Freedom Arc-Resistant MCCs to ensure proper configuration and installation.
Device Specifications and Configurations
The document outlines device configurations and specifications, including unit types, trip ratings, and unit sizes. Device types are categorized with specific codes, and unit types are defined as single or dual disconnects.
Motor Control Centers (MCC)
The document details different types of MCC starters and provides a list of common modification codes for MCCs.
Accessories and Options
Eaton’s MCCs offer a range of accessories and options, including high ampacity molded case breakers and safety accessories like Motorguard and FlashGard.
Arc-Resistant Motor Control Centers
The Freedom arc-resistant MCC is designed to protect personnel from arc flash hazards, featuring enhanced structural integrity and tested per IEEE and CSA standards.
Technical Data and Specifications
Specifications for Freedom arc-resistant MCCs include voltage ratings and communication options like Modbus and EtherNet/IP.
Incoming Line Configurations
The document describes incoming line configurations for main lugs and circuit breakers, with guidelines for installation and configuration.
Overview
The document provides detailed technical specifications for circuit breakers and MCCs used in power distribution and control assemblies.
Specifications
  • Current Limiting Molded Case Circuit Breakers: Models include HFD/CL and NBTRIPAC with ratings from 150 to 800 A.
  • Magnum DS Air Circuit Breakers: Models such as MDS-608 and MDS-C32 with ratings from 800 to 3200 A.
Motor Control Centers (MCCs)
  • Structure: Options for NEMA 1, 2, 3R, or 12 enclosures with copper bus configurations.
  • Units: Includes Freedom Motor Starters, soft starters, adjustable frequency drives, and various control devices.
  • Protection and Monitoring: Surge protection, energy monitoring, and advanced metering options.
Check Sheets and Configuration Options
  • Detailed check sheets for Freedom and Freedom FlashGard MCCs.
  • Component count sheets for starters, breakers, VFDs, and transformers.
Key Features
  • Heavy-duty construction with arc-resistant designs.
  • Comprehensive range of control and protection devices.
  • Flexible configurations to meet specific customer requirements.
See more

Catalog excerpts

Motor Control Centers-1

Motor Control Centers Freedom MCC Product Offering Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aftermarket Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories and Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freedom, Freedom Arc-Resistant and Freedom Freedom Arc-Resistant MCC Check Sheets Check Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freedom and Freedom FlashGard Check Sheets Check Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Learn Online Freedom FlashGard

 Open the catalog to page 1
Motor Control Centers-2

Motor Control Centers Page V3-T3-3 V3-T3-4 V3-T3-4 V3-T3-4 V3-T3-4 V3-T3-7 Product Overview MCC Operation Eaton's motor control center (MCC) product line is headquartered in Fayetteville, NC. At Fayetteville, the most progressive engineering team in the industry can custom design motor control centers for the most demanding applications. Most MCCs can be shipped six to eight weeks after receipt of a released order. The MCC product line also offers a FAST motor control center (MCC) quick shipment program. The program includes integration of a number of commonly used components and assemblies in...

 Open the catalog to page 2
Motor Control Centers-3

Motor Control Centers Aftermarket Products XT Freedom Motor Control Center Production Years 2012-Present 1995-present 2002-2011 1992-2010 1987-1995/ 1988-1994 1972-1989 1965-1975 1956-1974 1935-1965 F10 Unitrol Type W 9800 Unitrol 11-300 Type Dates Background Over 50 years ago, Cutler-Hammer® and Westinghouse® low voltage motor control centers were introduced, enabling the group mounting of low voltage (600 V class) electrical controls. This allowed for supervision and safe operation of motor starter units, feeder tap units and auxiliary equipment in a flexible structure arrangement...

 Open the catalog to page 3
Motor Control Centers-4

Motor Control Centers Product Description Eaton's offering of motor control centers (MCCs) features the Freedom, Freedom arc-resistant, Freedom FlashGard, XT and XT FlashGard. These MCCs incorporate the newest NEMA electromechanical starters in the industry along with the most complete, NEMA rated package of distribution and control equipment. The FlashGard MCCs are the industry's first MCCs designed for comprehensive arc flash prevention. Application Description Eaton's MCCs are custom-made assemblies of conveniently grouped control equipment primarily used for control of motors and for distribution...

 Open the catalog to page 4
Motor Control Centers-5

Motor Control Centers Catalog Number Selection Aftermarket MCC Starter Buckets MCC Type Catalog Codes F = Free-standing NEMA 1 FZ = Freedom FK = Advantage FS = Series 2100/5 Star FD = Freedom Unitrol FR = F10 Unitrol FT = Type W FN = 9800 Unitrol FJ = 11-300 FM = IT. SZ = FlashGard GD = ITE 5600 GE = GE 7700/8000 AB = Allen-Bradley Centerline SQ = Square D Model 6 SS = Furnas 89 Starter Type See tables on Page V3-T3-6 Space Option Code S = Standard height C = Compact X = Oversized CPT C10 = Separate source control fuse C12 = 100 VA for sz. 1–2 C13 = 150 VA for sz. 3–4 Modification Codes See tables...

 Open the catalog to page 5
Motor Control Centers-6

Motor Control Centers Aftermarket MCC Starter types Full-Voltage Non-Reversing Combination Starter— HMCP Disconnect Maximum Horsepower HMCP Starter NEMA Ampere Class Size 208 V 240 V 380 V 480 V 600 V Size Code Common Modifications Abbreviated list of common modification codes Note: Please contact your local Service Center for all available modifications and to learn which modifications will work for your aftermarket needs. Modification Codes Full-Voltage Reversing Combination Starter— HMCP Disconnect Maximum Horsepower HMCP Starter NEMA Ampere Class Size 208 V 240...

 Open the catalog to page 6
Motor Control Centers-7

Accessories and Options Control and Distribution Equipment Packaging Eaton's MCCs provide the best packaged solutions for the control needs of today's users. Structural characteristics allow the user to select a complete package of control and distribution equipment in a minimum amount of space. The ability to package a wide range of solid-state products, including SVX9000 drives, S811+ soft starters and PLCs meet the most demanding user process needs. The option to provide high ampacity molded case breakers gives the user the flexibility to minimize switchboard or switchgear structures and thereby...

 Open the catalog to page 7
Motor Control Centers-8

Motor Control Centers Freedom, Freedom Arc-Resistant and Freedom FlashGard Technical Data and Specifications Freedom Arc-Resistant Motor Control Center Features and Benefits . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . Application Guide . . . . . . . . . . . . . . . . . . . . . . . . . Product Specifications . . . . . . . . . . . . . . . . . . . . . Freedom Arc-Resistant Motor Control Center Product Description An arc flash is a dangerous condition associated with the explosive release of energy caused by an electrical arc due to either...

 Open the catalog to page 8
Motor Control Centers-9

Motor Control Centers Freedom, Freedom Arc-Resistant and Freedom FlashGard Technical Data and Specifications No Exhaust Plenums or Roof Flaps Required Eaton’s arc-resistant Freedom MCC requires no exhaust plenums or roof flaps. This aids in the ease of installation, as additional clearance or venting ductwork is not required above the assembly. 12 Gauge Steel Doors, Side Sheets and Back Sheets Usage of 12 gauge steel on all MCC doors, side sheets and back sheets serve to increase the structural integrity of the MCC and aid in the containment of arc blast energy, further enhancing personnel safety...

 Open the catalog to page 9

All Cutler-Hammer catalogs and technical brochures

  1. Fuses

    291  Pages

  2. OEM Product

    334  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.