Jockey Pump Controllers
2Pages

{{requestButtons}}

Catalog excerpts

Jockey Pump Controllers - 1

Jockey Pump Controllers JOCKEY Touch" Jockey Pump ControllersMicroprocessor Based with Color Touchscreen Product Description ACROSS THE LINE JOCKEY PUMP CONTROLLERS The JOCKEY Touch - Jockey Pump Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single motor starter. Starting inrush current is approximately 600% of rated full load amperes. WYE-DELTA (Star-Delta) JOCKEY PUMP CONTROLLERS When six or twelve-lead delta connected jockey pump motors are started wye (star) connected, approximately 58% of line voltage is applied to each winding. The motor develops 33% of full-voltage starting torque and draws 33% of normal locked-rotor current from the line. After an adjustable time delay (during which the motor accelerates), it is reconnected for normal operation. Product Features Combination Motor Controllers All JOCKEY Touch controllers are supplied with EATON combination motor controllers, which combine the circuit breaker and overload in one device. Sealed Rotary Handle Mechanism The rotary handle mechanism can be padlocked in the OFF position. XT Power Controls The JOCKEY Touch - Jockey Pump Controllers incorporate Eaton's XT Power Controls which are designed for the global marketplace. The XT controls carry global ratings, are small in size and are available in a wide variety of operating voltages. They are easy to install and maintain, due to their modular, plug-in design. Universal Supply Voltage The controllers will auto-detect three phase voltage supply from 200VAC to 600VAC, 50/60Hz and single phase from 110VAC to 240VAC, 50/60Hz, without the use of a control transformer. NEMA 2 Enclosures Enclosures have an oven baked powder paint finish and are supplied with NEMA 2 rating, unless otherwise ordered. Available options include: NEMA 3R, 4, 4X, 12. Programmable Functions Inputs, Outputs, Timers and Virtual LED's are programmable via the touchscreen display. Starting Methods There are four methods of starting the controller: Auto, Hand, Remote Start and Pump Start. Diagnostics / Statistics Eight diagnostics and seven statistics parameters can be monitored. Alarm Setpoints Four alarm setpoints can be programmed from the Alarm Setpoints sub-menu. Color Touchscreen Display The JOCKEY Touch - Jockey Pump Controllers are supplied with a microprocessor based, color touchscreen. The touchscreen display allows the user to monitor and program functions and values. Pressure input is provided by a 4-20mA pressure sensor. Standards & Certification The JOCKEY Touch - Jockey Pump Controllers meet the requirements of the latest edition of NFPA 20 as well as meeting CE mark requirements. They meet or exceed the requirements of UL 508 [Underwriters Laboratories (UL)] and are approved by [Canadian Standards Association (CSA)]. Technical Data ACROSS-THE-LINE (Direct On Line) JOCKEY PUMP CONTROLLERS Line Voltage 200-208V 220-240V 380-415V 440-480V 550-600V 120V-1Ph 240V-1Ph WYE-DELTA (Star-Delta) JOCKEY PUMP CONTROLLERS Line Voltage 200-208V220-240V380-415V440-480V550-600V Motor Horsepower 1/3-40Hp 1/3-40Hp 1/3-50Hp 1/3-50Hp 1/3-50Hp F;T*N Powering Business Worldwide

Open the catalog to page 1
Jockey Pump Controllers - 2

Jockey Pump Controllers JOCKEY Microprocessor - Color Touchscreen Display Touch SuddIv Voltage 3 phase - 200VAC to 600VAC. S0/60Hz Programmable Types 1 phase - 110VAC to 240VAC, 50/60Hz Minimum Run Timer True RMS measurement of 3 phase voltage inputs Sequential Start Timer Pump Run Restart Timer Power Supply Output Acce eration Timer Fail to Start Timer Power the pressure sensor Energize the contactor coil Programmable Functions (22) Ratings Transducer Failure Programmed settings saved in Non Volatile memory 6 Low Pressure Alarm 17 Remote Start High Pressure Alarm Battery Backup 8 Below...

Open the catalog to page 2

All Cutler-Hammer catalogs and technical brochures

  1. Fuses

    291 Pages

  2. OEM Product

    334 Pages

Archived catalogs