Product Overview
The LMR PLUS Electric Fire Pump Controllers with Transfer Switch are designed to provide reliable automatic transfer from normal to alternate power sources when required. They are compliant with various standards including NFPA 20, UL, and CE mark.

Key Features
  • Automatic Transfer Switch: Can be integrated with any FD type Fire Pump Controller for automatic power transfer.
  • ATC-300 Plus Controller: Monitors power sources and operates the transfer switch with programmed sensing and timing functions.
  • Engine Test Button: Allows testing of the generator engine with selectable run time.
  • LED Status Indication: Provides visual status of power sources and unit status.
  • Communication Options: Includes USB, Ethernet, and RS485 ports for data transfer and communication.
  • Embedded Web Page: Allows viewing and programming of controller status and settings via an Ethernet connection.

Specifications
  • Voltage and Frequency Sensing: Ensures automatic transfer when voltage drops to 85% of normal or phase issues occur.
  • Output Relays: Standard configuration includes seven relays with options for additional relay boards.
  • Display and Controls: Features a backlit LCD display and membrane keypad for programming and status indication.

Programming and Diagnostics
  • Programming Menu: Divided into sub-menus for language, regional settings, pressure, timers, alarm set points, and custom inputs/outputs.
  • Diagnostics: Provides eleven diagnostic points for troubleshooting.
  • Message History: Stores up to 10K events with time and date stamps.

Standards and Certification
The controllers meet or exceed requirements from Underwriters Laboratories, Factory Mutual, and other regulatory bodies.

Additional Features
  • Emergency Start Operator: Allows manual activation of the motor contactor.
  • Drain Valve Solenoid: Used for weekly test purposes.
  • NEMA Enclosures: Available in various ratings including NEMA 2, 3R, 4, 4X, and 12.
See more

Catalog excerpts

FT30 ACROSS-THE-LINE-1

LMR PLUS Electric Fire Pump Controllers with Transfer Switch Features FT30 Full Voltage - Full Service - Across the Line Electrically and Mechanically Interlocked The FT Series transfer switch operating mechanisms are mechanically interlocked to prevent the normal and alternate source from connecting at the same time. The switch operates upon signals received from the ATC-300 Plus controller. 1-1 January 2012 Automatic Transfer The FT Series Transfer Switches will perform an automatic transfer from Normal to Alternate source when the Voltage drops to 85% of normal, or there is a loss of any phase and/or Phase Reversal. ATC-300 Plus Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer Switch and Fire Pump Controller are mounted in the same enclosure or in separate enclosures to form one unit and interwired - depending on the horsepower and voltage required. Engine Test Button An engine test button is provided on the ATC300 controller that can be used to test the Source 2 (generator) engine. The operator can select the engine run test time (0-600 minutes). As well, a silence pushbutton is provided which de-energizes the alarm bell. The panel mounted, multi-function, microprocessor based ATC-300 Plus controller accurately monitors two power sources and provides the necessary intelligence to reliably operate the transfer switch through a series of programmed sensing and timing functions. Keypad Programming The ATC-300 Plus controller membrane is equipped with seven keypad input buttons which are used to program the controller as well as set operating parameters. LED Status Indication Five LED’s indicate the status of the power sources. Source 1 Available Source 1 Connected Source 2 Available Source 2 Connected Unit Status Voltage and Frequency Sensing The ATC-300 Plus continuously monitors the normal source for out of range setpoint values. When the source is outside the dropout setpoints, the source will become unavailable. This prompts a transfer to the alternate source. Retransfer occurs when the normal source’s frequency and/or voltage return within pickup setpoints. Alarm Relay The alarm relay is de-energized to indicate an absence of an alarm state and energized to indicate the presence of an alarm condition. Alarm conditions include: Improper Circuit Breaker Operation Motor Operator Failure Lockout Failsafe Condition Aborted Engine Test Aborted Plant Exerciser Unsuccessful in-phase Transition Product Features Power I/O Board The FT30, Transfer Switch Controller operates Across-The-Line where full voltage is applied to the motor for starting by the use of a single motor contactor. Starting inrush current is approximately 600% of rated full load amperes. The FT30 can be programmed for either fully automatic or semiautomatic operation. Transformers Incoming line voltage is run directly to the I/O board from the incoming lines. The three transformers mounted on the I/O board will accept voltage inputs between 100 and 600V. Customer Connection Terminals Connection terminals for external customer connections, are located on the top of the Power I/O board. Logic Controller Board Communication The controller can be ordered with the option to display and output current values and status, on command, from various software protocols through the appropriate port(s). Embedded Web Page The web page is a multifunction tool that allows the user to view the controller’s current status, data values, programmed set points and history. It is accessed using the optional ethernet port. USB Port / USB Drive Ethernet Port An optional ethernet port is used for direct connection to a computer for data transfer. RS485 Serial Port An optional RS485 serial port can be provided for communication to various external software programs. Buzzer A buzzer is mounted on the logic board which will operate if Fail to Start, Hardware Malfunction or any Common Alarm condition exists. The logic controller board is equipped with a USB port that can be used to transfer data to and from a portable USB Drive device (memory stick). Output Relays Seven socket mount, 8 Amp, 2 Form - C (DPDT) output relays are provided standard on each power I/O board. They are designated for: Common Alarm, Phase Failure, Phase Reversal, Pump Run, Startup, Acceleration and Future # 1. Each socket has an LED mounted on the I/O board which indicates each relay’s coil status. Optional Output Relay Boards There is provision to add up to eight additional relay outputs, via optional relay output boards. Each board contains a maximum of 2 additional relays. The Power I/O Board will accept a maximum of 4 optional boards which mount in a snap-on conguration. Each board provides an area for the user to label the terminal number and relay name. For more information visit: www.chfire.com BR05805058K/L

 Open the catalog to page 1
FT30 ACROSS-THE-LINE-2

LMR PLUS Electric Fire Pump Controllers with Transfer Switch Features FT30 Full Voltage - Full Service - Across the Line Door Mount The membrane keypad is accessible from the front door of the controller. NEMA Rating The standard membrane keypad is rated for NEMA 2, 3R, 4, 4X and 12. MAIN DISPLAY General The main display will show the current system pressure, time and date, voltage and amps reading for all three phases, the system frequency and any custom messages, alarms or timers. 1-2 January 2012 Firmware Update Firmware revisions are updated from an external USB drive. All previously programmed...

 Open the catalog to page 2
FT30 ACROSS-THE-LINE-3

LMR PLUS Electric Fire Pump Controllers with Transfer Switch Features FT30 Full Voltage - Full Serviice - Across-the-Line 1-3 January 2012 Product Features Programming Menu General The LMR Plus programming menu is divided into 8 different sub-menus. Each sub-menu contains information relative to it’s particular function. A brief description of each sub-menu is listed below. Language The language sub-menu allows the user to select English, French or Spanish or Other languages to be viewed on the LCD Display. Several other languages can be uploaded into the controller. Contact the factory for details....

 Open the catalog to page 3

All Cutler-Hammer catalogs and technical brochures

  1. Fuses

    291  Pages

  2. OEM Product

    334  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.