LMR PLUS Electric Fire Pump Controllers with Transfer Switch FT20 Full Voltage - Limited Service Electrically and Mechanically Interlocked The FT Series transfer switch operating mechanisms are mechanically interlocked to prevent the normal and alternate source from connecting at the same time. The switch operates upon signals received from the ATC-300 Plus controller. Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer Switch and Fire Pump Controller are mounted in the same enclosure or in separate enclosures to form one unit and interwired - depending on the horsepower and voltage required. Engine Test Button An engine test button is provided on the ATC300 controller that can be used to test the Source 2 (generator) engine. The operator can select the engine run test time (0-600 minutes). As well, a silence pushbutton is provided which de-energizes the alarm bell. The panel mounted, multi-function, microprocessor based ATC-300 Plus controller accurately monitors two power sources and provides the necessary intelligence to reliably operate the transfer switch through a series of programmed sensing and timing functions. Keypad Programming The ATC-300 Plus controller membrane is equipped with seven keypad input buttons which are used to program the controller as well as set operating parameters. LED Status Indication Five LED’s indicate the status of the power sources. Source 1 Available Source 1 Connected Source 2 Available Source 2 Connected Unit Status Product Features The web page is a multifunction tool that allows the user to view the controller’s current status, data values, programmed set points and history. It is accessed using the optional ethernet port. The logic controller board is equipped with a USB port that can be used to transfer data to and from a portable USB Drive device (memory stick). Automatic Transfer The FT Series Transfer Switches will perform an automatic transfer from Normal to Alternate source when the Voltage drops to 85% of normal, or there is a loss of any phase and/or Phase Reversal. Voltage and Frequency Sensing The ATC-300 Plus continuously monitors the normal source for out of range setpoint values. When the source is outside the dropout setpoints, the source will become unavailable. This prompts a transfer to the alternate source. Retransfer occurs when the normal source’s frequency and/or voltage return within pickup setpoints. Alarm Relay The alarm relay is de-energized to indicate an absence of an alarm state and energized to indicate the presence of an alarm condition. Alarm conditions include: Improper Circuit Breaker Operation Motor Operator Failure Lockout Failsafe Condition Aborted Engine Test Aborted Plant Exerciser Unsuccessful in-phase Transition Power I/O Board Incoming line voltage is run directly to the I/O board from the incoming lines. The three transformers mounted on the I/O board will accept voltage inputs between 100 and 600V. Customer Connection Terminals Connection terminals for external customer connections, are located on the top of the Power I/O board. Logic Controller Board The controller can be ordered with the option to display and output current values and status, on command, from various software protocols through the appropriate port(s). The FT20 Limited Service Transfer Switch Controller can be used for motors 30HP or less, driving special fire service pumps where acceptable to the authority having jurisdiction. They are available with across-the-line starting only, with starting inrush current approximately 600% of rated motor full load amperes. All models are supplied with an LMR Plus microprocessor. Ethernet Port An optional ethernet port is used for direct connection to a computer for data transfer. An optional RS485 serial port can be provided for communication to various external software programs. A buzzer is mounted on the logic board which will operate if Fail to Start, Hardware Malfunction or any Common Alarm condition exists. Output Relays Seven socket mount, 8 Amp, 2 Form - C (DPDT) output relays are provided standard on each power I/O board. They are designated for: Common Alarm, Phase Failure, Phase Reversal, Pump Run, Startup, Acceleration and Future # 1. Each socket has an LED mounted on the I/O board which indicates each relay’s coil status. Optional Output Relay Boards There is provision to add up to eight additional relay outputs, via optional relay output boards. Each board contains a maximum of 2 additional relays. The Power I/O Board will accept a maximum of 4 optional boards which mount in a snap-on configuration. Each board provides an area for the user to label the terminal number and relay name. For more information visit: www.chfire.com
Open the catalog to page 1LMR PLUS Electric Fire Pump Controllers with Transfer Switch FT20 Full Voltage - Limited Service Door Mount The membrane keypad is accessible from the front door of the controller. NEMA Rating The standard membrane keypad is rated for NEMA 2, 3R, 4, 4X and 12. MAIN DISPLAY General The main display will show the current system pressure, time and date, voltage and amps reading for all three phases, the system frequency and any custom messages, alarms or timers. Firmware Update Firmware revisions are updated from an external USB drive. All previously programmed settings will remain intact when...
Open the catalog to page 2LMR PLUS Electric Fire Pump Controllers with Transfer Switch FT20 Full Voltage - Limited Service Product Features Programming Menu General The LMR Plus programming menu is divided into 8 different sub-menus. Each sub-menu contains information relative to it’s particular function. A brief description of each sub-menu is listed below. Language The language sub-menu allows the user to select English, French or Spanish or Other languages to be viewed on the LCD Display. Several other languages can be uploaded into the controller. Contact the factory for details. Regional Regional settings...
Open the catalog to page 3All Cutler-Hammer catalogs and technical brochures
-
FT90 Bid Submittal
13 Pages
-
FDF/FTF20 Bid Submittal (Foam)
18 Pages
-
Booster Pump Controllers
12 Pages
-
DFDAP-M / FDAP-M
5 Pages
-
Jockey Pump Controllers
2 Pages
-
Eaton EPCT Fire
4 Pages
-
Remote Alarm Panels
5 Pages
-
Mining solutions linecard
4 Pages
-
Mining solutions
5 Pages
-
Data center solutions
7 Pages
-
NEMA contactors and starters
154 Pages
-
Motor Control Centers
27 Pages
-
Arc-flash safety solutions
12 Pages
-
Fuses
291 Pages
-
Counters, Timers and Tachometers
130 Pages
-
Vehicle and Commercial Controls
204 Pages
-
Enclosed Control - Product Catalog
541 Pages
-
OEM Product
334 Pages
-
Sensing Solutions
561 Pages
-
Solid-State Motor Control
498 Pages
-
Motor Control and Protection
778 Pages
-
Circuit Protection
705 Pages
-
Residential and Light Commercial
401 Pages
-
Commercial Distribution
710 Pages
-
FDAP-M ELECTRIC
1 Pages
-
XTJP JOCKEY PUMP CONTROLLERS
1 Pages
-
MEDIUM VOLTAGE CONTROLLERS
2 Pages
-
FT90 SOFT START
3 Pages
-
FT60 AUTOTRANSFORMER
3 Pages
-
FT50 PRIMARY RESISTOR
3 Pages
-
FT40 Part Winding
3 Pages
-
FT30 ACROSS-THE-LINE
3 Pages
-
FT20 LIMITED SERVICE
3 Pages
-
FD90 SOFT START
2 Pages
-
FD60 AUTOTRANSFORMER
2 Pages
-
FD50 PRIMARY RESISTOR
2 Pages
-
FD40 PART WINDING
2 Pages
-
FD30 ACROSS-THE-LINE
2 Pages
-
FD20 LIMITED SERVICE
2 Pages
-
DIESEL ENGINE CONTROLLERS
2 Pages
Archived catalogs
-
Booster Pump Controllers
12 Pages