FDF120 DIESEL ENGINE ADDITIVE (FOAM) PUMP CONTROLLERS
2Pages

{{requestButtons}}

Catalog excerpts

FDF120 DIESEL ENGINE ADDITIVE (FOAM) PUMP CONTROLLERS - 1

FDF Additive (Foam) Pump Controllers Powering Business Worldwide FDF120 Diesel Engine Additive (Foam) Pump Controllers Product Description The DIESEL Plus Foam Pump Controllers from Eaton Corporation are designed to control and monitor 12 or 24 volt, diesel fire pump engines and are among the most technically advanced diesel engine controllers available. They are an enhanced version of the original diesel engine controllers. Programming is firmware and menu structure utilized in the LMR Plus Series of electric controllers. The controller can be ordered with the option to display and output current values and status, on command, from various software An embedded web page for retrieving diagnostics and history reports, can be accessed from the optional Ethernet communication port. An optional Rs485 serial port can be used for direct connection to a computer for data Product Features The embedded web pages allow the user to view the current status of the controller as well as all amperage readings, set points, diagnostics and history. An external computer connected via the optional ethernet port is used to access the pages. The specific data required can be downloaded for reference Communication Types The controller can communicate with the diesel engine electronic control module optional Canbus (SAE J1939) engine port. The USB port is used to download the controller message history, statistics, diagnostics, status and configuration data to a USB disk drive. The USB port can also be used to upload custom messages, additional languages, and update the microprocessor An external computer can be communicate with the Diesel Plus controller via the optional ethernet port. An embedded web page will display the controller's current status, as well as display all current readings, set points and The Diesel Plus fire pump controllers have the option to communicate to systems using the Regular level of Modbus (includes both RTU and ASCII transmission modes). Communication settings are user configurable through the Diesel Plus configuration menu. Field Connections Standard Inputs • Deluge Valve • Pump Start Programmable Inputs Up to 10 additional, programmable inputs can be programmed to indicate up to 13 different types of inputs. They can be programmed to energize the common alarm output, link to relays and optional LED's and latch until reset All optional inputs, outputs and LED's can be linked, as required. They can also be programmed with time delay functions. Standard Output Relays All standard output relays are 8 amp, DPDT • Auto Mode • Common Alarm Optional Output Relays There is provision to add up to eight additional relay outputs, via four optional relay output boards which mount in a snap-on configuration. Each board contains a maximum of 2 additional The Power I/O Board houses a 10 Amp engine run relay which is used for alarm purposes, or to power external louvers. Common Alarm Relay The FDF120 controller has a common alarm relay which energizes whenever there are any alarm conditions present. This relay is energized under normal conditions and has LED status indication. Alarm Relay Rating All alarm relays are rated 10 amps, 220Vac, 1/3HP resistive load only. Programmable Outputs Up to 10 additional, programmable outputs (two standard; eight via optional output boards) can be programmed to indicate up to 45 output conditions. They can be programmed for fail safe and latch until reset by the user. All optional inputs, outputs and LED's can be linked, as required. They can also be programmed with time delay functions. As well, six optional alarm LED's can be programmed Power / Voltage Universal Voltage Supply The controller can be powered with supply voltages from 90Vac to 240Vac by connecting to the three input terminals L,N,G located on the bottom left of Dual Output 12 or 24Vdc output is selectable via a DIP Switch located on the battery chargers. Note: Each controller is factory set for 12Vdc. If 24Vdc is required from the factory, it should be noted on the ordering information. Line Filter A line filter incorporated onto the engine board, is used to reduce/eliminate external incoming voltage A breaker located inside the controller on the Engine Board, is used to switch on and off AC power to the unit. It will illuminate when energized. The engine board houses two on-board circuit breakers used to switch on or off DC power from Each breaker has an LED mounted on the engine board that illuminates when the breaker is For more information visit: www.chfire.com

Open the catalog to page 1
FDF120 DIESEL ENGINE ADDITIVE (FOAM) PUMP CONTROLLERS - 2

Powering Business Worldwide FDF Additive (Foam) Pump Controllers FDF120 Diesel Engine Additive (Foam) Pump Controllers Alarm and Status Indication Diagnostics All alarm and status LED's as well as the LCD Display and programming buttons are accessible from the front of the controller. The Controller Display Board contains a 4 Line by 40 Characters wide, backlit, LCD display which is capable of generating multiple languages. The display will show the current system pressure, time and date, charger output voltage and any custom messages, alarms or timer values. Alarm & Status LED's Status...

Open the catalog to page 2

All Cutler-Hammer catalogs and technical brochures

  1. Fuses

    291 Pages

  2. OEM Product

    334 Pages

Archived catalogs