DFDAP-M / FDAP-M
5Pages

{{requestButtons}}

Catalog excerpts

DFDAP-M / FDAP-M - 1

Remote Alarm Panels FeaturesDFDAP-M / FDAP-M Remote Alarm Panel March 2011 Product Description Eaton's Remote Alarm Panels are designed to provide audible and visual alarms for Electric and Diesel Fire Pump Controllers. These remote panels are located at a point of constant attendance when the pump room is not constantly supervised. Product Features Microprocessor Control All DFDAP-M and FDAP-M Remote Alarm Panels are microprocessor based. The same microprocessor board is used for both Electric and Diesel units. Power Supply Voltages Both Normal and Supervisory (backup) power supply voltages can be supplied from 110 to 240Vac, 50-60 Hz. Both Normal and Supervisory power is supplied by customer. Normal / Supervisory (backup) Power Source If the Normal power source is not available, the controller will automatically switch to the Supervisory (backup) source. When normal power is restored, the controller will switch back to the normal source. Audible Alarm An audible buzzer will sound when any alarm condition occurs. It will continue to sound until either the Silence Alarm button is pressed, or the alarm condition is satisfied. Lamp Test Button The lamp test button on the membrane will simultaneously test all LED's. Silence Alarm Button The Silence Alarm button on the membrane will silence all active alarms when pressed, but has no effect on the associated alarm LED(s). If another alarm condition occurs after the silence button has been pressed, the alarm buzzer will re-sound until the button is pressed again, or the alarm condition is satisfied. User Selectable Alarm Inputs Each panel accepts up to eight (8) inputs. Each input can be selected as either normally open or normally closed by use of jumpers on the microprocessor board. "Normal Power On” Indication The Normal Power On LED will turn ON when the normal power is available and will turn OFF when the controller switches to the Supervisory (backup) power source. The alarm buzzer will sound when the normal power is not available and will remain ON until the normal power is restored, or the Silence Alarm button is pressed. Output Relays Output relays are PCB style - rated for 8A/250VAC. NEMA1 Enclosures All remote alarm panels come standard with NEMA 1 enclosures. Membrane Indication Inputs five (5) and six (6) are directly connected to two LED's on the bottom left on the membrane. A space is provided beside each LED for labeling purposes. Inputs seven (7) and eight (8) are directly connected to two LED's on the bottom right on the membrane. As well as LED indication and labeling area on the membrane, they will each provide an output signal from a corresponding SpDt, 8Amp relay. Electric ■ Normal Power On ■ Supervisory Power On ■ Pump Running ■ Phase Failure ■ Phase Reversal ■ Common Alarm ■ Custom - (2) ■ Custom with SPDT, 8Amp relay Output - (2) Diesel ■ Normal Power On ■ Supervisory Power On ■ Engine Running ■ Not In Auto Mode ■ Low Fuel ■ Common Alarm ■ Custom - (2) ■ Custom with SPDT, 8 Amp relay Output - (2) Standards & Certification Technical Data and Specifications Line Terminals (Incoming Cables) The DFDAP-M / FDAP-M Remote Alarm Panels meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, the Canadian Standards Association, the New York City building code, and are built to NFPA 20 standards. For more information visit: www.chfire.com BR0580

Open the catalog to page 1
DFDAP-M / FDAP-M - 2

Remote Alarm Panels Main Display Main Display - DFDAP-M Diesel Engine Remote Alarm Panel March 2011 F.T«IM NORMAL POWER ON O ENGINE RUNNING O LOW FUEL O 1 o I o '\ Diesel Remote Alarm Panel O SUPERVISORY POWER ON O NOT IN AUTO MODE O COMMON ALARM O I I LAMP TEST SILENCE ALARM ) MD05805158K/B For more information visit: www.chfire.com

Open the catalog to page 2
DFDAP-M / FDAP-M - 3

Remote Alarm Panels Dimensions June 2010 DFDAP-M Diesel Remote Alarm Panel Dimensions Standard Enclosure - Type NEMA 1 - Diesel Remote Alarm Panel CONTROL CIRCUIT VOLTS SERIAL NO. 16BJ709E ENCL. TYPE CONTROL CIRCUIT VOLTS SERIAL NO. 16BJ709E ENCL. TYPE NOTES: 1. All enclosures finished in FirePump red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 1. For more information visit: www.chfire.com

Open the catalog to page 3
DFDAP-M / FDAP-M - 4

Electrical Wiring Schematic Remote Alarm Panels Electrical Wiring Schematic DFDAP-M Diesel Remote Alarm Panel March 2011 TD KEYPAD AUDIBLE ALARM JUMPERS TL SET INPUTS AS NORMALLY / OPEN DP NORMALLY CLOSED, INPUT PDLARITY LOCATED IN MAIN FIRE PUMP CUNTRULLER LEGATED IN MAIN EIRE PUMP CONTROLLER EE TADLE FUR TEPMIMALGI ALL RELAY' CONTACTS ARE SHOWN IN NO POWER CONDITION. INPUTS 5 AND 6 ARE LINKED TO CUSTOM LIGHTS IN THE LERT OR THE PROMT DISPLAY. INPUTS 7 AND 8 ARE LINKED TO CUSTOM LIGHTS ON THE RIGHT OR THE FRONT DISPLAY AND OUTPUT RELAYS 7 AND 8 ES05805133K/E For more information visit:...

Open the catalog to page 4
DFDAP-M / FDAP-M - 5

Powering Business Worldwide DFDAP-M / FDAP-M Remote Alarm Panels Typical Specifications1. Approvals A. The Remote Alarm Panel shall meet the requirements of the latest edition of NFPA 20 and shall be listed by [Underwriters Laboratories (UL)] [Underwriters Laboratories of Canada (ULC)] approved by [Canadian Standards Association (CSA)] and have MEA approval for New York City. 2. Construction A. The remote alarm panel shall be equipped with a Lamp Test button which, when operated, fully tests all LED's. The Lamp Test Button shall not change the state of internal relays. B. The panel shall...

Open the catalog to page 5