Penny & Giles • Contactless design - Inductive technology • Wear-free operation • Separate signal conditioning (EICT) o High performance driver circuit o Zero and span adjustment o Choice of enclosure designs The ICT100 Contactless In-Cylinder Linear Transducer has been specifically designed for mobile and static hydro-pneumatic actuators. Designed primarily for the off-highway markets, the ICT100 linear transducer provides reliable, fit-and-forget position sensing of the cylinder rod in actuators with strokes up to 1,800mm, with a body diameter of only 10.1 mm. It is a robust, non-contact transducer suitable for the harsh conditions of lifting and steering position applications and hydro-pneumatic active suspension systems. It works on an inductive coil principle, with virtually infinite resolution and is capable of withstanding temperatures down to -55°C and up to +200°C, with working pressures to 670Bar (10,000psi). The EICT signal-conditioning module has been specifically designed to operate with the Penny and Giles range of SLT and ICT contactless linear position transducers. The module incorporates a high performance circuit that drives the transducer and provides a choice of output signals with zero and span adjustment for simple user configuration. The module can be supplied in a choice of enclosures, with sealing to IP66 or IP68 protection.
Open the catalog to page 1© 2023 Curtiss-Wright. All rights reserved. Curtiss-Wright accepts no responsibility for possible errors in catalogs, brochures and other printed material. Curtiss-Wright reserves the right to alter its products without prior notice. This also applies to products already Ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. 2 | Page
Open the catalog to page 2Code Description EM External flange - metric EU External flange - unified RM Reverse threaded flange - metric RU Reverse threaded flange - unified Code Description TM Threaded core - metric TU Threaded core - unified Code Description XXXX 25mm to 200mm full electrical stroke length selectable in 5mm increments 210mm to 1100mm full electrical stroke length selectable in 10mm increments 1120mm to 1800mm full electrical stroke length selectable in 20mm increments Stroke length is always written as four digits e.g. 80mm = 0080 and 880mm = 0880
Open the catalog to page 3A ±0.25% total stroke maximum, typically less than ±0.20% B ±0.50% total stroke maximum, typically less than ±0.25% The ICT100 requires one of the following signal conditioning modules (ordered separately) EICT Corrosion resistant plastic enclosure sealed to IP66, with detail to fit rail DIN EN50022 or EN50035 or bulkhead mount via four M5 screws EICTM Powder coated metal enclosure sealed to IP68 with bulkhead mounting via four M5 screws The following accessories for the signal-conditioning module are also available (ordered separately) VM Voltage module output option card CM Current module output...
Open the catalog to page 4INSTALLATION SENSOR MECHANICAL DIMENSIONS Threaded Core
Open the catalog to page 5Sleeved Core
Open the catalog to page 6SENSOR INSTALLATION KIT The installation kit is dependent upon the temperature rating. AI202800 applies for the H option and AI207803 applies for the L option in the configuration code. Item Number Wavy washer Shim washer Anti-extrusion ring Copy of installation drawing Label – supplied loose 12 Installation kit label P203193 P207804 1 Item 11 (Label) is supplied for the customer to record ICT ordering code and is to be fitted in visible location adjacent to sensor for reordering reference SUGGESTED SENSOR FITTING PROFILES The installation details shown here are suggestions only because of the...
Open the catalog to page 7Threaded Flange Machining Details To seal use item 6 from the appropriate installation kit Sleeved Core Machining Details
Open the catalog to page 8Threaded Core Machining Details MlNlMJM FNEE :iPAFE FOR ^ETJfiN 31L FLCw. THREADED CORE ASSEMBLYMB x 1.25 OR 5/16 -24 UNE SIGNAL CONDITIONING MODULE MECHANICAL DIMENSIONS
Open the catalog to page 9Bulkhead fixing dimensions Cable glands Cable diameter must Enclosure provided with four fixing holes be between 3.0 and 8.0mm diameter to to accept M5 screw x 30mm long minimum. maintain IP68 rating of the enclosure. Cover removed for illustrative purposes ELECTRICAL CONNECTIONS -O -V supply (Dual supply only) -O 0V return -O Voltage (current) output
Open the catalog to page 10The green wire is internally connected to the transducer case. Due to the construction of the transducer external moving parts, the green connection should not be used as a ground connection. The enclosure is not connected internally to ground, so it can be mounted on a chassis carrying a voltage potential other than 0Vdc Misconnection of the supply may cause permanent damage. Maximum recommended distance between transducer and signal conditioning module is 10m. Each transducer is supplied with a sensor calibration module card (SCMC), calibrated to match the electrical stroke length. The EICT...
Open the catalog to page 11If using a voltage module, connect the VM card by inserting connector into position on header JP2 of EICT/EICTM PCB. Do not insert CM or PWM cards at this stage. Connect a DMM set to measure voltage to the output (terminal 5) and GND (terminal 6) on the EICT/EICTM PCB. Move the transducer core to the fully 'Lo' position (See Step 4 and Fig. 2) and power up the EICT/EICTM. Adjust ZERO trim pot until the required output voltage is achieved on the DMM display (0.5Vdc if no VM card is fitted in JP2). For Dual Supply option, output over the full range, relative to ground ('GND' 0V) will appear on...
Open the catalog to page 12• EICT/EICTM must be disconnected from the transducer to carry out following check. • Using a DMM, set to the resistance range: • Measure between connections assigned to transducer 'yellow' and 'blue'. Value should lie between 400 and 1700. • Measure between connections assigned to transducer 'green' and 'yellow' and/or 'blue'. Value should be 'open circuit'. • Measure between connections assigned to 'green' and the transducer body. Value should be 'short circuit'. • 'Screen', if used - Connections assigned to 'screen' should be 'open circuit' to all the other electrical connections and transducer...