BTPC Bypass Isolation Transfer Switch Open or Closed Transition

BTPC Bypass Isolation Transfer Switch Open or Closed Transition
1 / 12 PagesView full catalog

BTPC Bypass Isolation Transfer Switch Open or Closed Transition

Product catalog summary
Overview
The BTPC Bypass Isolation Transfer Switch is engineered for critical applications requiring dependable power transfer. It integrates an automatic transfer switch with a manual bypass switch, facilitating seamless power transfer and re-transfer. It is available in both open and closed transition modes, supporting loads from 150 to 4000 Amps.
Key Features
  • PowerCommand Control: Microprocessor-based control with a digital display for easy settings adjustments and event scheduling.
  • Closed Transition: Allows transfer without power interruption by briefly connecting two power sources.
  • Programmed Transition: Suitable for inductive loads, allowing for load disconnection for a set period.
  • Closed Door Operation: Provides arc flash protection by enabling operations behind closed doors.
  • Advanced Mechanism: Includes a bi-directional linear actuator for smooth operation and a robust control system design with surge protection.
Specifications
  • Voltage Rating: 600 VAC, 50 or 60 Hz.
  • Operating Temperature: -40°F to 140°F (-40°C to 60°C).
  • Humidity: Up to 95% relative, non-condensing.
  • Altitude: Up to 10,000 ft (3,000 m) without de-rating.
Certifications
  • UL 1008 Listed with UL Type Rated cabinets.
  • Complies with NFPA 70, 99, and 110 (Level 1).
  • Certified to CSA 282 for Emergency Electrical Power Supply.
  • Complies with NEMA ICS 10 and IEEE 446.
Transition Modes
  • Open Transition/Programmed: Controls switching time to ensure safe voltage levels before connecting to an energized source.
  • Open Transition/In-Phase: Transfers when sources are in phase, with a backup programmed transition.
  • Closed Transition: Briefly parallels two sources to avoid power interruption.
Additional Features
  • Manual Bypass: Allows selection between normal or emergency sources without disturbing power supply.
  • Isolation Mechanism: Separates automatic and bypass switches electrically and mechanically.
  • Communications Capability: Compatible with LonWorks protocol for integration with building systems.
Specifications
The document details specifications for Cummins transfer switches, including amperage ratings from 150 to 4000 amps and voltage ratings from 190 to 600 volts. It covers pole configurations, frequency options (50 or 60 Hertz), and transfer modes (open transition/in-phase, open transition/programmed, closed transition).
Procedures
The transfer switches can alternate between two gensets at intervals up to 336 hours. They require protection by specific circuit breakers or fuses, with detailed drawings available for reference. The document specifies the withstand and closing ratings (WCR) in symmetrical RMS amperes for different transfer switch amperages.
Standards and Compliance
The switches comply with UL 1008/CSA certification and NFPA 20 standards, although NFPA 20 is not available for 1200-4000 amp switches. Seismic certification is also mentioned.
Enclosures
Transfer switches are housed in key-locking enclosures with dimensions provided for both UL Type 1 and other types (3R, 4, 4x, 12). The document specifies the enclosure types suitable for indoor and outdoor use, offering protection against various environmental factors.
Recommendations and Options
Various system options are available, including auxiliary relays, miscellaneous options like terminal blocks and loadshed features, and optional lug kits for different cable capacities. Enclosure types range from indoor to outdoor use, with options for stainless steel and open construction.
Additional Features
The document lists control options, meters, battery chargers, and protective relays. It also outlines warranty terms, covering parts, labor, and travel for the first two years, with parts coverage extending up to ten years.
Key Data from Tables
The tables provide detailed information on the maximum ratings for MCCB and CLB protection, fuse protection, 3-cycle ratings, and transfer switch lug capacities. They also include dimensions and weights for various enclosure types and configurations.
See more

Catalog excerpts

BTPC Bypass Isolation Transfer Switch Open or Closed Transition-1

Specification Sheet BTPC Bypass Isolation Transfer Switch Open or Closed Transition 150 – 4000 Amps Description BTPC bypass isolation transfer switches combine a draw out automatic transfer switch with isolation mechanism and a manual bypass switch, to provide redundant power transfer and re-transfer capability for critical need applications requiring a reliable power supply to the load. BTPC switches are available with closed transition for transferring critical loads without interruption. PowerCommand® control: A fully featured Microprocessor based control with digital display. Controls allow operator to enter settings and make adjustments to software enabled features easily and accurately. Accommodates up to 8 event schedules. Like conventional transfer switches, BTPC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator sets. The switch monitors both power sources, signals generator set start up, automatically transfers power and returns the load to the primary power source when the utility returns and stabilizes. Closed transition available: By briefly connecting the two sources (for 100 msec or less), the transfer from the alternate source back to the normal source occurs without Interruption in the power supply to loads. Programmed transition: Open transition timing can be adjusted to completely disconnect the load from both sources for a programmed time period, as recommended by NEMA MG-1 for transfer of inductive loads. Closed door draw out operation: Bypass and total isolation of the automatic transfer switch occurs behind closed doors, to provide arc flash protection for operator. For critical loads: Suitable for use in emergency, legally required and optional Standby applications.

 Open the catalog to page 1
BTPC Bypass Isolation Transfer Switch Open or Closed Transition-2

BTPC Bypass-Isolation Transfer Switch Advanced transfer switch mechanism: Unique bi-directional linear actuator provides smooth, Continuous transfer switch action during automatic operation. Robust control system design: Optically isolated logic inputs and isolation transformers for AC power inputs provide high-voltage surge protection. Main contacts: Heavy-duty silver alloy contacts and multi-leaf arc chutes are rated for motor loads or total system load transfer. They require no routine contact maintenance. Continuous load current not to exceed 100% of switch rating and Tungsten loads not to...

 Open the catalog to page 2
BTPC Bypass Isolation Transfer Switch Open or Closed Transition-3

Transfer Switch Mechanism Bypass Mechanism • Transfer switch mechanism is electrically operated and mechanically held in the Source 1 and Source 2 positions. The transfer switch incorporates electrical and mechanical interlocks to prevent inadvertent interconnection of the sources. • Independent break-before-make action is used for both 3pole and 4-pole/ switched neutral switches. This design allows use of sync check operation when required, or control of the operating speed of the transfer switch for proper transfer of motor and rectifier-based loads (programmed transition feature). • True 4-pole...

 Open the catalog to page 3
BTPC Bypass Isolation Transfer Switch Open or Closed Transition-4

PowerCommand Control PowerCommand controls are microprocessor based and developed specifically for automatic transfer switch operation. The control includes the features and options required for most applications. • Flash memory stores the control settings. • Contents of the memory are not lost even if power to the controller is lost. • On-board battery maintains the real-time clock setting and the engine start time delay. Panels Basic indicator panel: Source available/connected LED indicators Test/exercise/bypass buttons Digital display: Standard Analog bar graph meter display: optional (D009)...

 Open the catalog to page 4
BTPC Bypass Isolation Transfer Switch Open or Closed Transition-5

PowerCommand Control (continued) Time-Delay Functions User Interface Options Engine start: Prevents nuisance genset starts due to momentary power variation or loss. Not included in utilityto-utility systems. Transfer normal to emergency: Allows genset to stabilize before application of load. Prevents power interruption if normal source variation or loss is momentary. Allows staggered transfer of loads in multiple transfer switch systems. For genset-to-genset applications, delays transfer of load from lead to secondary generator. Re-transfer emergency to normal: Allows the utility to stabilize...

 Open the catalog to page 5
BTPC Bypass Isolation Transfer Switch Open or Closed Transition-6

Specifications Voltage rating Multiple leaf arc chutes provide dependable arc interruption. A full current-rated neutral bar with lugs is standard on enclosed 3-pole transfer switches. Auxiliary contacts Two isolated contacts (one for each source) indicating switch position are provided for customer use. Contacts are normally open, and close to indicate connection to the source. Wired to terminal block for easy access. Rated at 10 amps Continuous at 250VAC maximum. UL recognized and CSA-certified. Operating temperature Storage temperature Surge withstand ratings Voltage surge performance and...

 Open the catalog to page 6
BTPC Bypass Isolation Transfer Switch Open or Closed Transition-7

Transition Modes Open transition/programmed: Controls the time required for the device to switch from source to source, so that the load-generated voltages decay to a safe level before connecting to an energized source. Recommended by NEMA MG1 to prevent nuisance tripping breakers and load damage. Adjustable 0-10 seconds, default 0 seconds. Programmed transition is standard on 150-1000 amp switches, and optional on 1200-4000 amps. Open transition/in-phase: Initiates open transition transfer when in-phase monitor senses both sources are in phase. Operates in a break-before-make sequence. Includes...

 Open the catalog to page 7
BTPC Bypass Isolation Transfer Switch Open or Closed Transition-8

UL Withstand and Closing Ratings The transfer switches listed below must be protected by circuit breakers or fuses. Referenced drawings include detailed listings of specific breakers or fuse types that must be used with the respective transfer switches. Consult with your distributor/dealer to obtain the necessary drawings. Withstand and Closing Ratings (WCR) are stated in symmetrical RMS amperes. MCCB protection Transfer switch ampere WCR @ volts max with specific manufacturers MCCBs Special circuit breaker protection Drawing reference With specific current limiting breakers (CLB) Drawing reference...