Foreword
Users are advised to thoroughly read and understand the manual before installation, operation, or repair to prevent injury or damage. Unauthorized removal of parts is prohibited. Specifications may change without prior notice.

Packing List
The package includes a Spiro analyzer gas bench, a user manual, an optional RS232 line, and a power supply module.

Working Principle
The analyzer uses a micro-flow infrared gas sensor to measure CH4 and CO concentrations. Infrared light passes through a chopper and measurement cell, where gases absorb some light. The detector measures the remaining light to determine gas concentration.

Specifications
Measurement range for CH4 and CO is 3000ppm with a resolution of 1ppm. The device operates with a gas flow of 0.7 to 1.2 L/min and requires sample gas free of water vapor, dust, and oil. It has a response time of less than 1 second and requires a warm-up time of over 30 minutes.

Structure and Function
The gas sensor module includes components such as a sensor signal, signal amplifier, main board, and RS232 protocol.

Interface Definition
The main board interface includes connections for an electric motor, fan, power supply, keyboard, LCD display, RS232, and sensor signal. The wiring terminal provides various voltage and communication connections.

RS232 Usage
Data can be transferred via RS232 after disconnecting the power supply. The process involves warming up, zeroing with zero gas, and taking measurement results.

User Calibration
Calibration is necessary after some use to correct drift, following specific commands in the communication protocol.

Operation and Maintenance
After setup, the module should warm up for 10-15 minutes before testing. Maintenance includes checking for gas leaks, ensuring screws are tight, removing dust, and periodic sensor adjustments.
See more

Catalog excerpts

Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-1

SPIRO ANALYZER GAS BENCH USERS MANUAL Specification spiro analyzer gas bench Wuhan Cubic Optoelectronics Co.Ltd ADD: Fenghuang Yuan No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China TEL: +86-27-81628831 FAX: +86-27-87401159 Http://www.gassensor.com.cn E-mail: [email protected]

 Open the catalog to page 1
Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-2

I Foreword 1.Pls reading and understanding the content completely the operation manual before installation, operation and repairing the instrument .There would be happen to human injury or analyzer damage if your operation unqualified. 2.Never remove the configuration and spare parts of the instrument unless approving by company. Our company will be derelict of duty due to the user make bold to remove the configuration and spare parts mistakenly. 3.The specification and guide content of this analyzer may be changed due to the technology improve of the product. Pls forgive us shall not give out...

 Open the catalog to page 2
Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-3

SPIRO ANALYZER GAS BENCH USERS MANUAL 1.Abstract Spiro analyzer gas bench / module uses state-of-the-art micro-flow infrared gas sensor , measuring CH4/CO concentration with fast response ,high accuracy and long stability .The gas analysis module is designed of simple structure, easy operation,long lifespan, with power supply modules, RS-232 data communication lines It’s an ideal gas module for PFT(Pulmonary Function Test) system . ①-- Infrared light source ②-- Chopper ③—Chopper motor ④—Measurement cell ⑤-- Detector ⑥—Micro-flow sensor ⑦、⑧—The 2nd measurement cell and detector ⑨-- Signal processing...

 Open the catalog to page 3
Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-4

SPIRO ANALYZER GAS BENCH USERS MANUAL ※ NoteMeasure range can be customized, the output voltage can be adjusted. Gas flow Pressure of gas inlet Requirement of sample gas Response time(TD+T90) Warm-Up time Output interface Work Temperature Relative Humidity Atmospheric Pressure Dimension 0.7 1.2 L/min <10KPa Remove water vapor,dust(<1um) and oil etc. <1S (NDIR) >30min Voltage signal output 050℃ 585% 86108kPa 360mm×140mm×74mmwidth×length×height 1.4 Function module of gas sensor Sensor signal Signal amplifier Main board Function module picture of gas sensor

 Open the catalog to page 4
Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-5

SPIRO ANALYZER GAS BENCH USERS MANUAL 1.6 Definition of interface 1.6.1 Definition of main board interface

 Open the catalog to page 5
Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-6

1.6.2 Definition of wiring terminal SN During transfer the data by RS232 cable ,pls first disconnect the power supply of equipment to prevent equipment damage.

 Open the catalog to page 6
Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-7

SPIRO ANALYZER GAS BENCH USERS MANUAL 2. Installation 2.1 Using RS232 Users can get the sensor measurement result from serial port, the communication protocol command according to Annex. Workflow is as follows: 1. Warm-up: need warm-up for some time.the signal is unstable during this period. 2. Zeroing: inlet zero gasO2/N2 more than 10s after the sensor stability, Send zero command "11 01 03 EB" and complete zeroing, adjust the sensor measurements result to 0. 3. Take measurements result: send "11 01 01 ED" order, read the measurement results. Send “11 01 03 EB” order complete zeroing send “...

 Open the catalog to page 7
Specification of Micro-flow multigas analyzer CO and CH4 3000ppm-8

SPIRO ANALYZER GAS BENCH USERS MANUAL Warm up half an hour After signal stability, send zero adjustment order “4B”,complete zeroing. RS232 zero adjustment Warm up half an hour After signal stability, send zero adjustment order “4C”,complete zeroing. RS232 span adjustment 3. Operation and Maintenance 3.1 Operation After finishing circuit and pneumatic routine of gas sensor module, power it on, then the module start to work. We suggest you can do the test after 10 to 15 minutes for warming-up. Open the pump of gas sensor module for sampling in order to absorbing the sample gas, screw the flow meter...