PM2015-M Laser Particle Sensor Module

PM2015-M Laser Particle Sensor Module
1 / 21 PagesView full catalog

PM2015-M Laser Particle Sensor Module

Product catalog summary
Overview: The PM2105-M is a laser particle sensor module designed for indoor use, utilizing laser scattering technology to measure particle concentrations from 0.3μm to 10μm. It provides real-time outputs for PM1.0, PM2.5, and PM10 in μg/m³ with high accuracy and sensitivity.
Key Features:
  • Measurement range: 0.3μm to 10μm
  • Real-time output for PM1.0, PM2.5, PM10
  • High accuracy and quick response time (≤8s)
  • Signal output options: UART, I²C, PWM
  • Four measuring modes: single, continuous, timing, dynamic
  • RoHS and Reach compliant
Specifications:
  • Operating principle: Laser scattering
  • Measurement range: 0~1000μg/m³
  • Resolution: 1μg/m³
  • Operating conditions: -10°C to 60°C, 0-95%RH
  • Storage conditions: -40°C to 80°C, 0-95%RH
  • Power supply: DC 5V±0.1V
  • Dimensions: 42×35×23.7 mm
Applications: Suitable for air purifiers, air quality monitors, air conditioners, ventilation systems, consumer electronics, and environmental monitoring.
Installation Guidelines:
  • Ensure unobstructed air inlet and outlet
  • Avoid dust deposition on sensitive components
  • Install above 20cm from the floor to prevent contamination
  • Not suitable for outdoor use or high-security applications
Communication Protocols:
  • UART and I²C protocols available
  • Default continuous mode after power-on
  • Commands available for reading particle measurements, setting measurement times, and controlling the laser diode
Safety and User Attention:
  • Defined as a 3R laser product; avoid direct eye exposure
  • Ensure stable and low-noise power supply
  • Use 5V power supply for the fan, with 3.3V communication level
Dynamic Measuring Mode Setup: To set up the dynamic particle measuring mode, send the command 11 02 06 DF1 [CS]. The mode can be read with 11 01 06 E8. The response confirms the setup with 16 02 06 DF1 [CS]. The mode is controlled by the DF1 value: 00 closes the mode, and 01 starts it. In dynamic mode, the sensor measures every 30 seconds, with specific actions based on the difference between consecutive measurements.
Working Modes: The module supports four working modes: Single, Continuous, Timing, and Dynamic. Commands are provided to switch between these modes, with Continuous being the default. For example, 11 03 0D 00 24 BB sets Single mode, and 11 03 0D FF FF E1 sets Continuous mode.
Particle Calibrated Coefficient: To set or read the particle calibrated coefficient, use 11 02 07 DF1 [CS] and 11 01 07 E7 respectively. The coefficient range is 70 to 150, corresponding to 0.7 to 1.5, and it adjusts PM1.0, PM2.5, and PM10 values.
Laser Diode Control: The laser diode can be closed with 11 02 08 04 E1 and its status read with 11 01 08 E6. When closed, the sensor stops measuring but the fan continues to operate.
Software Version and Serial Number: Commands 11 01 1E D0 and 11 01 1F CF are used to read the software version and serial number, respectively. The software version is converted from HEX to ASCII.
I²C Communication Protocol: The protocol involves commands sent by the main controlled board to the sensor module, which cannot initiate communication. The communication clock frequency is ≤100Khz. Commands include starting and stopping measurements, setting measurement times, and adjusting calibration coefficients.
Work Mode Descriptions: Each work mode has specific behaviors: Single mode involves a 36-second measurement; Continuous mode keeps the sensor active; Dynamic mode involves a 30-second cycle with specific conditions for continued measurement; Timing mode involves periodic measurements based on a set interval.
Packing Information: Sensors are packed in trays with 30 units per tray, 13 trays per carton, totaling 390 sensors per carton. The carton dimensions are 395x310x480 mm, using red pearl cotton for packing.
See more

Catalog excerpts

PM2015-M Laser Particle Sensor Module-1

SPECIFICATION Product Name: Laser Particle Sensor Module Item No.: PM2105-M Version: V0.3 Date: June 3, 2020

 Open the catalog to page 1
PM2015-M Laser Particle Sensor Module-3

Laser Particle Sensor Module PM2105-M Applications ▪ Air purifier ▪ Air quality monitor ▪ Air conditioner ▪ Ventilation system ▪ Consumer electronic products ▪ Environmental monitoring ▪ Description PM2105-M is a laser particle sensor module for indoor use based on laser scattering technology. This sensor can measure particle concentration size between 0.3μm~10μm exactly and output particle mass concentration PM1.0, PM2.5, PM10 in μg/m³ directly via mathematical algorithm and scientific calibration. ▪ The smallest size of available measurement: 0.3μm ▪ Real-time output PM1.0, PM2.5, PM10 in μg/m3...

 Open the catalog to page 3
PM2015-M Laser Particle Sensor Module-5

Internal Architecture Description When the fan works, it will generate airflow. When the particles in the sampled gas pass through the beam of the light source (laser), a light scattering phenomenon occurs, and the scattered light is converted into an electrical signal (ie, a pulse) by the photoelectric transformer. The larger the particle size, the larger the amplitude of the pulse signal outputs. The number of particles of different sizes is calculated by comparing the peak value with the predetermined threshold value, and the mass concentration value is obtained by a professional algorithm....

 Open the catalog to page 5
PM2015-M Laser Particle Sensor Module-6

The interface connector is located at the side of the sensor. Corresponding female plug part number is SM08B-GHS-TB from JST. The pitch is 1.25mm. The connection cable with female connector at both ends can also be customized.

 Open the catalog to page 6
PM2015-M Laser Particle Sensor Module-7

Typical Application Circuit Case 1. UART Application 5V-3.3V Level Shift, RX, TX Level Shift

 Open the catalog to page 7
PM2015-M Laser Particle Sensor Module-8

Temperature Influence Curve Particle measured error: under 25±2℃, 0~1,000μg/m³, consistency and accuracy of PM1.0/PM2.5 is either ±15% reading or ±15μg/m³, the bigger one is considered. Temperature influence coefficient: 0.5%/℃ ~ 1%/℃ or 0.5μg/m³/℃ ~ 1μg/m³/℃, the bigger one is considered.

 Open the catalog to page 8
PM2015-M Laser Particle Sensor Module-9

Product Installation ▪When install PM2105-M sensor module in your system or equipment, please make sure that the air inlet and air outlet are unobstructed. And there is no huge airflow face to air inlet and air outlet. ▪In order to avoid dust deposition on the surface of sensitive component (laser diode and photosensitive diode), which may affect the measurement accuracy of the sensor, the appropriate installation ways are recommended as below. Recommended Installation Cross section Photosensitive diode surface

 Open the catalog to page 9
PM2015-M Laser Particle Sensor Module-10

User Attention ▪The best installation way is to make the surface of air inlet and outlet of the sensor clings to the air vent in the inner wall of the user device that communicates with the outside. If it’s not possible, then an air isolation structure between air inlet and air outlet is necessary to avoid the air back flow in the user’s device. ▪Air vent size on the internal wall of user’s device for airflow should be bigger than the size of air inlet of the sensor. ▪For purification products, sensor cannot be installed in the purifying air duct. If it’s not possible, it’s necessary to design...

 Open the catalog to page 10
PM2015-M Laser Particle Sensor Module-11

1) The data in this protocol is all hexadecimal data. For example,“46” for decimal [70]. 2) [xx] is for single-byte data (unsigned, 0-255); for double data, high byte is in front of low byte. 3) Baud rate: 9600; Data Bits: 8; Stop Bits: 1; Parity: No 4) It is default by continuous mode after powering on. Working mode will not be saved after powering off. Sending format of software:

 Open the catalog to page 11
PM2015-M Laser Particle Sensor Module-12

4.1 Read Particle Measurement Result Send: 11 02 0B 07 DB Response: 16 35 0B DF1- DF52 [CS] Function: Read concentration of particle and particles number. Note: Read particle concentration (ug/m3) and particles number (pcs/0.1L) PM1.0 GRIMM mass concentration = DF1*256A3 + DF2*256A2 + DF3*256A1 + DF4 PM2.5 GRIMM mass concentration = DF5*256A3 + DF6*256A2 + DF7*256A1 + DF8 PM10 GRIMM mass concentration = DF9*256A3 + DF10*256A2 + DF11*256A1 + DF12 PM1.0 TSI mass concentration = DF13*256A3 + DF14*256A2 + DF15*256A1 + DF16 PM2.5 TSI mass concentration = DF17*256A3 + DF18*256A2 + DF19*256A1 + DF20...

 Open the catalog to page 12
PM2015-M Laser Particle Sensor Module-13

// Close particle measurement Response: 16 02 0C 01 DB// module is under particle measurement closed status 4.3 Set up and Read Particle Measuring Time Send: 11 03 0D DF1 DF2 [CS] Send: 11 01 0D E1 // Set up particle measuring time // Read particle measuring time Response: 16 03 0D DF1 DF2 [CS] Function: Read particle measuring time Note: 1. Particle measuring time = DF1*256+DF2, unit is second. Minimum measuring time is 36 seconds. Time range is 36-65530 seconds. After setting up xx seconds particle measuring time, the sensor will stop working first, then you can send “Open” command to start...

 Open the catalog to page 13
PM2015-M Laser Particle Sensor Module-14

Send: 11 03 05 02 05 E0 // Set up as timing measuring mode, and timing cycle is 517seconds. Response: 16 03 05 02 05 DB // Set up successfully 4.5 Set up Dynamic Measuring Mode Send: 11 02 06 DF1 [CS] // Set up dynamic particle measuring mode Send: 11 01 06 E8 // Read dynamic particle measuring mode Response: 16 02 06 DF1 [CS] Function: Read/set up particle dynamic measuring mode Note: 1. Particle dynamic measuring mode result DF1 2. When DF1=00, close dynamic measuring mode. When DF1=01, start dynamic measuring mode. Dynamic working mode description: After sensors are in dynamic working mode,...

 Open the catalog to page 14
PM2015-M Laser Particle Sensor Module-15

Send: 11 02 06 01 E6 // Set up opening dynamic particle measuring mode Response: 16 02 06 01 E1 // Set up successfully Send: 11 02 06 00 E7 // Set up closing dynamic particle measuring mode Response: 16 02 06 00 E2 // Set up successfully Remark: The module can support 4 kinds of working mode (Single+Continuous+Timing+Dynamic). It can be switched between these 4 kinds of working mode. It is continuous working mode by default after leaving factory. These 4 kinds of working mode can be switched by sending commands, as following: 1. Send: 11 03 0D 00 24 BB // Single measuring mode, time is 36s. After...

 Open the catalog to page 15
PM2015-M Laser Particle Sensor Module-17

a. This is an I2C protocol for PM2105-M. The sensor module is lower computer, which is not able to initiate communication automatically. Communication is initiated via main controlled board, which reads data and Sends control commands. b. Communication clock frequency <=100Khz. START: start signal, send by main controlled board; STOP: stop signal, send by main controlled board; ACK: acknowledge signal, send by the sensor module if in bold; otherwise, send by main controlled board; NACK: non-acknowledge signal, send by the sensor module if in bold; otherwise, send by main controlled board; Px:...

 Open the catalog to page 17