Group: Cubic
Catalog excerpts

SPECIFICATION Product Name: NDIR CO2 Sensor Module Item No.: CM1106H-NS Version: V0.4 Date: May 26, 2020
Open the catalog to page 1
NDIR CO2 Sensor Module CM1106H-NS Applications ▪ HVAC industry ▪ IAQ monitor ▪ Air purifier ▪ Automotive ▪ IoT devices ▪ Plant growth Description Infrared carbon dioxide CO2 sensor CM1106H-NS can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology (NDIR). It is widely used in ventilation system, air conditioner, air purifier, IAQ monitor, agriculture, plant cultivation and cold-chain, etc. Features ▪ NDIR technology with independent intellectual property ▪ Temperature calibration within whole measurement range ▪ Long life span,...
Open the catalog to page 3
Specifications Single Beam NDIR CO2 Sensor Specification Operating principle Non-dispersive infrared (NDIR) Measurement range Working temperature Working humidity Storage temperature Storage humidity Sampling frequency Time to first reading Power supply Ripple wave Working current Signal output Life span Maintenance-free for normal indoor application with Auto-calibration Note 1:Sensor is designed to measure in the range 0~2000ppm (PWM), 0-10000ppm (UART) with specified in the table. Nevertheless exposure to concentrations below 400ppm may result in incorrect operation of ABC algorithm and...
Open the catalog to page 4
Dimensions and Connector 1. Dimensions (Unit mm, tolerance ±0.2 mm) Power supply input (4.5V-5.5V) Power supply output (3.3V/100mA) Power supply input (GND) Alarming (Reserved) RS485 control site (Reserved) Manual calibration
Open the catalog to page 5
Typical Application Circuit Case1. (1) UART_TTL 3.3V output 5V level and 3.3V level conversion circuit
Open the catalog to page 6
Description of Calibration Auto Calibration: Rough installing and influence of transportation might result in reducing of sensor measuring accuracy and baseline drift, sensor will correct the drift by the built-in self-correcting logic, and the auto baseline correction period is 24h+7 days. Powering on the sensor for 24 hours continuously, it will record the lowest CO2 concentration measurement value during the 24 hours, which will be regarded as baseline (400ppm) when sensor do auto calibration after the 24 hours working, and then the sensor will enter regular 7 days correction cycle, auto...
Open the catalog to page 7
(1) Baud rate: 9600, Data Bits: 8, Stop Bits: 1, Parity: No, Flow Control: No (2) The data of this protocol are all hexadecimal data. For example, "46" is decimal [70]; (3) [xx] is single-byte data (unsigned, 0-255); double-byte data high byte first, low byte last; 2. UART protocol format Sending format of upper computer
Open the catalog to page 8
4. Detail Description of UART Protocol 4.1 Read Measured Result of CO2 Send: 11 01 01 ED Response: 16 05 01 DF1- DF4 [CS] Function: Read measured result of CO2 (Unit: ppm) Note:CO2 measured result = DF1*256 + DF2 Example: Response: 16 05 01 02 58 00 00 8A Explanation: Hex is converted to decimal: 02 is 02; 58 is 88 CO2 concentration=02*256+88 = 600ppm 4.2 CO2 concentration value single point calibration Send:11 03 03 DF1 DF2 CS Response:16 01 03 E6 Function:CO2 concentration value single point calibration Note: 1. Single point calibration target value = DF1*256 + DF2. The unit is in ppm and...
Open the catalog to page 9
After-Sales Services and Consultancy Cubic Sensor and Instrument Co., Ltd. Tel: +86 (0)27 81628827 Fax: +86 (0)27 81628821 Add: Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China E-mail: info@gassensor.com.cn
Open the catalog to page 11All Cubic Sensor and Instrument Co. catalogs and technical brochures
-
Cubic TDLAS CH4 Sensor
4 Pages
-
Gasboard-7500H-OPC
13 Pages
-
NDIR CO2 Sensor Module-CM1106LS
18 Pages
-
Laser Particle Sensor-PM2008M-M
22 Pages
-
Laser Particle Sensor-PM2012
19 Pages
-
Test Instruction of AM4100-I
7 Pages
-
Test Instruction of AM1008W
7 Pages
-
Test Instruction of PM5000
7 Pages
-
Test Instruction of PM1006
8 Pages
-
Test Instruction of CM1107T
7 Pages
-
Test Instruction of CM1107BN
8 Pages
-
Test Instruction of PM3006T
7 Pages
-
Test Instruction of PM2009
8 Pages
-
Test Instruction of CM1106SH
8 Pages
-
Test Instruction of CM1107
8 Pages
-
Test Instruction of CM1106S
8 Pages
-
Test Instruction of CM1106LS
8 Pages
-
Laser Particle Sensor-PM2008
21 Pages
-
Laser Particle Sensor-PM2009
20 Pages
-
Laser Particle Sensor-PM2105-M
20 Pages
-
NDIR CO2 Sensor Module-CM1106S
18 Pages
-
Gas Sensor Line-up
1 Pages
-
About Cubic
1 Pages
-
CEMS Solution - Gasboard 9050
22 Pages
-
NDIR CO2 Sensor Modules
7 Pages
-
Gasboard-7020
4 Pages
-
Gasboard-7500
7 Pages
-
Mainstream ETC02 module
5 Pages
-
Gasboard 3400P
5 Pages
-
Analyzer Gasboard 3800P
6 Pages
-
LANDFILL APPLICATIONS
8 Pages
Archived catalogs
-
Air quality monitor AM7000
11 Pages
-
RHB Series
8 Pages
-
Ultrasonic Flow meter 7200
1 Pages
-
Syngas portable analyzers
4 Pages
-
Opacity meter
1 Pages
-
Infrared Methane gas sensor
3 Pages