Introduction to CO2 Measurement
Measuring CO2 is crucial as high concentrations can be dangerous to health. According to NIOSH, levels above 40,000ppm are hazardous, and exposure to very high concentrations can cause severe health issues, including heart damage and loss of consciousness.
Ventilation Systems and CO2 Monitoring
Ventilation systems are essential for maintaining indoor air quality by introducing fresh air and removing polluted air. CO2 sensors are used to monitor indoor air and ensure CO2 levels remain below 1000ppm, which is considered safe.
Role of CO2 Sensors in HVAC Systems
CO2 sensors, particularly NDIR sensors, are vital for balancing indoor and outdoor CO2 levels. They provide continuous monitoring and send data to ventilation controls to maintain optimal air quality.
Benefits of CO2-Based Ventilation Systems
These systems improve indoor air quality, save energy by optimizing ventilation rates, and enhance comfort by maintaining a healthy indoor environment.
NDIR CO2 Sensor Technology
NDIR sensors are known for their high accuracy and low power consumption, making them ideal for detecting indoor CO2 levels. They are used in various applications, including IAQ monitoring and HVAC systems.
Features of Cubic NDIR CO2 Sensors
The sensors offer high accuracy with temperature calibration, high stability with auto-calibration, and are available in both single and dual beam options. They are compact and easy to install, suitable for multiple applications.
See more

Catalog excerpts

NDIR Carbon Dioxide Sensor for HVAC Application-1

NDIR Carbon Dioxide Sensor for HVAC Application

 Open the catalog to page 1
NDIR Carbon Dioxide Sensor for HVAC Application-2

IP Cubic ♦According to NIOSH (National Institute for Occupational Safety and Health), concentrations of 40000ppm or higher should be regarded as immediately dangerous to life and health. ♦Exposure to very high concentrations (eg. Exposure to 6% volume C02 for several minutes or 30% volume C02 for 20-30 seconds), has been linked to permanent heart damage. Concentrations greater than 10% are capable of causing loss of consciousness within 15 minutes or less. Exposure may lead to serious oxygen deprivation resulting in permanent brain damage, coma, even death Maximum allowed concentration within...

 Open the catalog to page 2
NDIR Carbon Dioxide Sensor for HVAC Application-3

CO2 sensor application in the HVAC system A ventilation system is a mechanical structure that is mainly used to control indoor(commonly homes and offices) air quality. Its main function is to introduce a constant supply of fresh air, usually from the outside. Managing the fresh air brought into the house and polluted air removed outside to realize proper ventilation rates is the key point. ●正文第一级内容(24号) of people are quite normal and maximum concentration CO2 levels above 1000ppm in a room with numbers may 正文第二级内容(20号) Ventilation system can use CO2 sensor to monitor the carbon ● occasionally...

 Open the catalog to page 3
NDIR Carbon Dioxide Sensor for HVAC Application-4

CO2 sensor application in the HVAC system How do CO2 sensors help to balance the CO2 concentration between indoor and outside through its ventilation system performance? ●It is important to use an affordable and stable sensor technology to measure carbon dioxide 正文第二级内容(20号) concentration to determine the correct level of fresh air in a zone. NDIR CO2 sensors continuously monitor CO2 levels of indoor air, which providing an indication of the amount CO2 concentration ●正文第三级内容(20号) between indoor and outside. An

 Open the catalog to page 4
NDIR Carbon Dioxide Sensor for HVAC Application-5

Benefits of CO2 measurement-based ventilation system Improved IAQ Poor indoor air quality may cause major health problems, such as allergies and respiratory diseases. When the CO2 levels in our house rise to an unacceptable level, ventilation system can control CO2 high level to the normal. Energy savings ● 正文第二级内容(20号) The energy saving for ventilation system can be achieved because CO2 sensor can help to provide ●正文第三级内容(20号) recommended ventilation rates to avoid excess heating, or cooling. Comfortable Normally, we spend approximately 60% of our time inside including home, office. So a comfortable...

 Open the catalog to page 5
NDIR Carbon Dioxide Sensor for HVAC Application-6

NDIR CO2 sensor for HVAC system With adopting advanced non-dispersive infrared technology(NDIR), NDIR CO2 sensor can be used to detect CO2 concentration of indoor air, featuring excellent performance characteristics, including high accuracy and low power consumption.

 Open the catalog to page 6
NDIR Carbon Dioxide Sensor for HVAC Application-7

Highlights of Cubic NDIR CO2 sensor The effectiveness of CO2 ventilation system relies upon the performance of CO2 sensors. A poor ventilation system can result in high CO2 level in the home or building. As ventilation system requirements become more strict, so do the performance of CO2 sensors. ◆High accuracy ● 正文第二级内容(20号) Temperature calibration within whole measurement range. ◆High stability Advanced auto-calibration at background. ◆Both single beam and dual beam available Suitable for lots of applications: IAQ monitor, ventilation system, air purifier, agricultural IoT, automotive, etc....