Group: Cubic
Catalog excerpts

SPECIFICATION Product Name: Laser Particle Count Sensor Module Item No.: PM5000 Version: V0.3 Date: June 3, 2020
Open the catalog to page 1
Laser Particle Count Sensor Module PM5000 Applications ▪ Clean Room ▪ Pharmaceuticals industry ▪ Precision machinery industry ▪ Microbiological industry Description PM5000 laser particle sensor module is based on laser scattering technology, which can accurately detect and calculate the number of suspended particles with different particle sizes in the air per unit volume. The built-in new patented technology intelligent identification of dust source can simultaneously output the number of particles in 6 channels including 0.3um, 0.5um, 1.0um, 2.5um, 5.0um and 10um (PCS/L). ▪ It can output...
Open the catalog to page 3
The interface connector of Sensor is JST B8B-XH-A. The pitch is 2.5mm. The connection cable with female connector at both ends can also be customized.
Open the catalog to page 5
Product Installation The surface of air inlet and air outlet closing to inner wall of user machine, this is the best installing method. If cannot do like this, there should be air isolation structure between inlet and outlet, thus to avoid the air flow return in the machine. The appropriate installation ways are recommended as below. Recommended installation Internal profile
Open the catalog to page 6
User Attention ▪When install PM5000 sensor module in your system or equipment, please make sure of unobstructed air-inlet and air-outlet. And make sure that there is no huge airflow faced to air-inlet and air-outlet. The inner profile and recommended installation as below for reference: to avoid dust deposit on the sensitive apparatus surface for the influence of the sensor accuracy. ▪The air inlet size in the user machine’s inner wall should not be smaller than the sensor’s air inlet size. ▪ It should not be installed directly in the air duct for purifying when applied in air purifying...
Open the catalog to page 7
1) The data in this protocol is all hexadecimal data. For example, “46” for decimal [70]. 2) [xx] is for single-byte data (unsigned, 0-255); for double data, high byte is in front of low byte. 3) Baud rate: 9600; Data Bits: 8; Stop Bits: 1; Parity: No 4) It is default by continuously mode after powering on. Working mode will not be saved after powering off. Sending format of software: 4.1 Read Particle Measurement Result Send: 11 02 0B 07 DB Response: 16 35 0B DF1- DF52 [CS] Function: Read measurement result. Note: Read particles number (pcs/L).
Open the catalog to page 8
DF50, DF51, DF52: Reserved Note: Part of reserved bit is used for our internal testing. The data changeable of reserved bit is nothing related to function. 4.2 Open/Close Particle Measurement Send: 11 03 0C DF1 1E CS Response: 16 02 0C DF1 CS Function: Open/ close particle measurement Note: 1. When sending command, DF1=02 means opening measurement, DF1=01 means closing measurement; 2. When receiving response, DF1=02 means measuring opened, DF1=01 means measuring closed; 3. When the sensor receives the command of opening measurement, it will be in default continuous testing mode. Example:...
Open the catalog to page 9
//module is under particle measurement open status //close particle measurement // module is under particle measurement closed status Serial number: 126231118063442
Open the catalog to page 10
a. This is an I2C protocol for PM5000. The sensor module is lower computer, which is not able to initiate communication automatically. Communication is initiated via main controlled board, which reads data and sends control commands. b. Communication clock frequency <=100Khz START: start signal, send by main controlled board; STOP: stop signal, send by main controlled board; ACK: acknowledge signal, send by the sensor module if in bold; otherwise, send by main controlled board; NACK: non-acknowledge signal, send by the sensor module if in bold; otherwise, send by main controlled board; Px:...
Open the catalog to page 11
Package Information After-Sales Services and Consultancy Cubic Sensor and Instrument Co.,Ltd. Tel: +86 (0)27 81628827 Fax: +86 (0)27 81628821 Add: Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China E-mail: info@gassensor.com.cn
Open the catalog to page 14All Cubic Sensor and Instrument Co. catalogs and technical brochures
-
Cubic TDLAS CH4 Sensor
4 Pages
-
Gasboard-7500H-OPC
13 Pages
-
NDIR CO2 Sensor Module-CM1106LS
18 Pages
-
Laser Particle Sensor-PM2008M-M
22 Pages
-
Laser Particle Sensor-PM2012
19 Pages
-
Test Instruction of AM4100-I
7 Pages
-
Test Instruction of AM1008W
7 Pages
-
Test Instruction of PM5000
7 Pages
-
Test Instruction of PM1006
8 Pages
-
Test Instruction of CM1107T
7 Pages
-
Test Instruction of CM1107BN
8 Pages
-
Test Instruction of PM3006T
7 Pages
-
Test Instruction of PM2009
8 Pages
-
Test Instruction of CM1106SH
8 Pages
-
Test Instruction of CM1107
8 Pages
-
Test Instruction of CM1106S
8 Pages
-
Test Instruction of CM1106LS
8 Pages
-
Laser Particle Sensor-PM2008
21 Pages
-
Laser Particle Sensor-PM2009
20 Pages
-
Laser Particle Sensor-PM2105-M
20 Pages
-
NDIR CO2 Sensor Module-CM1106S
18 Pages
-
Gas Sensor Line-up
1 Pages
-
About Cubic
1 Pages
-
CEMS Solution - Gasboard 9050
22 Pages
-
NDIR CO2 Sensor Modules
7 Pages
-
Gasboard-7020
4 Pages
-
Gasboard-7500
7 Pages
-
Mainstream ETC02 module
5 Pages
-
Gasboard 3400P
5 Pages
-
Analyzer Gasboard 3800P
6 Pages
-
LANDFILL APPLICATIONS
8 Pages
Archived catalogs
-
Air quality monitor AM7000
11 Pages
-
RHB Series
8 Pages
-
Ultrasonic Flow meter 7200
1 Pages
-
Syngas portable analyzers
4 Pages
-
Opacity meter
1 Pages
-
Infrared Methane gas sensor
3 Pages