Product Overview
The AM1008W is a compact indoor air quality sensor module designed for real-time measurement of air quality parameters. It integrates a laser particle sensor, NDIR CO2 sensor, VOC sensor, and temperature and humidity sensors, making it suitable for applications like air purifiers and ventilation systems.
Key Features
  • Integrated sensors for particle, CO2, VOC, temperature, and humidity.
  • Low power consumption with auto-calibration for CO2.
  • Ultra-thin design (12mm height) and strong anti-static capability.
Specifications
  • Measurement ranges: PM (0~1000μg/m³), CO2 (0~5000ppm), VOC (0~3 levels), Temperature (-20℃~70℃), RH (0-95%RH).
  • Accuracy: PM2.5 (±5μg/m³ or ±15%), CO2 (±50ppm+5%), Temperature (±1℃), RH (±8%RH to ±10%RH).
  • Preheating times: PM (≤8s), CO2 (≤30s), VOC (≤180s).
  • Working voltage: DC 5V±0.1V, average current ≤300mA.
  • Signal output: UART_TTL (3.3V TTL).
Installation and User Guidelines
  • Ensure unobstructed air-inlet and air-outlet.
  • Avoid dust on sensitive components.
  • Not suitable for high-security applications.
  • Use protective filters to prevent large particle pollution.
Communication Protocol
  • Data format: Hexadecimal, baud rate 9600.
  • Commands for reading measurements, CO2 calibration, and setting modes.
  • Dynamic measuring mode adjusts based on particle concentration.
Applications
  • Air purifiers, air quality monitors, air conditioners, ventilation systems, and consumer electronics.
Dynamic Particle Measuring Mode
The sensor operates in dynamic modes A or B, with a 30-second measurement cycle. Commands for dynamic mode setup include:
  • Open dynamic mode: Send 11 02 06 01 E6, Response 16 02 06 01 E1
  • Close dynamic mode: Send 11 02 06 00 E7, Response 16 02 06 00 E2
Working Modes
The module supports four modes: Single, Continuous, Timing, and Dynamic. Default is continuous mode. Commands to switch modes:
  • Single mode: Send 11 03 0D 00 24 BB
  • Continuous mode: Send 11 03 0D FF FF E1
  • Timing mode: Send 11 03 05 02 05 E0
  • Dynamic mode: Send 11 02 06 01 E6
Particle Calibrated Coefficient
  • Set up: Send 11 02 07 DF1 [CS]
  • Read: Send 11 01 07 E7, Response 16 02 06 DF1 [CS]
  • Range: 70~150 μg/m³, Coefficient: 0.7~1.5
Software Version
  • Read: Send 11 01 1E D0, Response 16 09 1E DF1 ~ DF8 [CS]
  • Convert HEX to ASCII for version number.
Serial Number
  • Read: Send 11 01 1F CF, Response 16 11 DF1…DF10 [CS]
  • Example: 126 2311 1806 3442
Packing Information
  • Sensors per tray: 16 pcs
  • Tray layers: 10
  • Sensors per carton: 160 pcs
  • Carton dimensions: 395*310*330mm
  • Packing material: Red anti-static EPE
Contact Information
Cubic Sensor and Instrument Co., Ltd.
Tel: +86 (0)27 81628827
Fax: +86 (0)27 81628821
Address: Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China
Email: [email protected]
See more

Catalog excerpts

Integrated Air Quality Sensor-AM1008W-1

SPECIFICATION Product Name: Integrated Air Quality Sensor Module Item No.: AM1008W Version: V0.3 Date: June 10, 2020

 Open the catalog to page 1
Integrated Air Quality Sensor-AM1008W-3

Integrated Air Quality Sensor Module AM1008W Applications ▪ Air purifier ▪ Air quality monitor ▪ Air conditioner ▪ Ventilation system ▪ Consumer electronic products ▪ Environmental monitoring Description AM1008W is an indoor air quality sensor module with highly integrated ultra-thin laser particle sensor, NDIR CO2 sensor, semiconductor VOC sensor, temperature and humidity sensor, which can real-time output digital measurement data. It is with stable performance, compact structure design, multi-function and optional connection ways, which can be widely used for IAQ monitor, air purifier, ventilation...

 Open the catalog to page 3
Integrated Air Quality Sensor-AM1008W-4

Note 1: In normal IAQ applications, accuracy is defined after minimum three (3) ABC periods of continuous operation with ABC on. Some industrial applications do require maintenance. Contact Cubic for further information. Note 2: Specification is referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (±2% currently) is to be added to the specified accuracy for absolute measurement.

 Open the catalog to page 4
Integrated Air Quality Sensor-AM1008W-5

The interface connector is located at the side of the sensor. Corresponding female plug part number is A1251WR-S-4P from CJT. The pitch is 1.25mm. The connection cable with female connector at both ends can also be customized.

 Open the catalog to page 5
Integrated Air Quality Sensor-AM1008W-6

Application Circuit UART TTL 3.3V UART output Test scenarios 3: 3.3V-5V switching circuit diagram If host MCU is 5V, it need to add the chip and circuit at the communication port (RX, TX) to make 5V transfer to 3.3V.

 Open the catalog to page 6
Integrated Air Quality Sensor-AM1008W-7

Measured error: under 25°C±2°C, 50±10%RH, 0~1000pg/m3, consistency and accuracy of PM2.5 is ±15% reading or ±15pg/m3, whichever is larger. Temperature influence coefficient: 0.5%/°C~1%/°C or 0.5pg/m3/°C~ 1pg/m3/°C, whichever is larger. Temperature Influence Curve of CO2 sensor | 2# sample A 3# sample X 4# sample X 5# sample 6# sample + 7# sample - 8# sample 9# sample + 10# sample

 Open the catalog to page 7
Integrated Air Quality Sensor-AM1008W-8

Product Installation ▪ When install AM1008W module in your system or equipment, please make sure of unobstructed air-inlet and airoutlet. And there is no huge airflow faced to air-inlet and air-outlet. ▪ In order to avoid dust deposition on the surface of sensitive component (laser diode and photosensitive diode), which may affect the measurement accuracy of the sensor, the appropriate installation ways are recommended as below. Recommended Installation , Cross section The blue is the front of laser diode

 Open the catalog to page 8
Integrated Air Quality Sensor-AM1008W-9

User Attention ▪AM1008W sensor module is for household electronics products. For application of medical, mining, disaster preparedness, which needs high security and high dependence, this sensor is not suitable. ▪The laser dust sensor adopts non-static adsorption materials such as metal, please avoid to working under the high particle concentration environment. ▪When you use the laser dust sensor, please make sure of unobstructed air-inlet and air-outlet. The CO2, VOC using diffusion for sampling, the gas diffusion hole should be reserved. ▪This sensor module should avoid working outdoors or...

 Open the catalog to page 9
Integrated Air Quality Sensor-AM1008W-10

1). The data in this protocol are all hexadecimal data. Such as "46 for decimal [70]" 2). [xx] for single-byte data (unsigned, 0-255); high byte of double byte data is in the front, the low byte in the back 3). Baud rate: 9600, data bits: 8, stopbits:1, parity: No. Sending format of software:

 Open the catalog to page 10
Integrated Air Quality Sensor-AM1008W-12

Function: CO2 calibration Statement: Format statement: 1. Calibration target value = DF1*256+DF2 2. Before CO2 calibration, make sure that the current ambient CO2 value is the target value you want to calibrate and that the stable time is at least 2 minutes. 4.3 Open and Close Particle Measurement Send: 11 03 0C DF1 1E CS Response: 16 02 0C DF1 CS Function: open and close particle measurement Statement: 1. When send command, DF1=02 is measurement open; DF1 =01 is measurement close; 2. When respond command, DF1=02 is measurement open; DF1=01 is measurement close; 3. When the sensor receives command...

 Open the catalog to page 12
Integrated Air Quality Sensor-AM1008W-13

Send: 11 01 0D E1 // read particle measuring time Response: 16 03 0D FF FF DC // read successfully 4.5 Set up Timing Measuring Mode Send: 11 03 05 DF1 DF2 [CS] // set up particle measuring mode Send: 11 01 05 E9 // read particle measuring mode Response: 16 03 05 DF1 DF2 [CS] Function: Read particle measuring time Note: 1. Particle measuring mode value X = DF1*256+DF2, unit is second; 2. When X >=60, it means module is under timing measuring mode. Measurement timing cycle is X seconds. The sensor module will start measurement every X seconds. Default measuring time is 36 seconds. 3. Range for...

 Open the catalog to page 13
Integrated Air Quality Sensor-AM1008W-14

The laser diode turns off for 11 seconds, enters the standby state, and outputs the B value. After the first 30 second period, the sensor starts a new 3 second measurement and outputs the A value. © If | A-B |> 10 ^g / m3 or | A-B | / B> 10%, the sensor selects Dynamic mode 1. The sensor measures continuously for 16 seconds and outputs the C value. The laser diode turns off for 11 seconds, enters the standby state, and outputs the C value. © If | A-B | <10 ^g / m3 or | A-B | / B <10%, the sensor selects Dynamic mode 2 and stores A value, then enters standby state for 27 seconds and outputs A...

 Open the catalog to page 14
Integrated Air Quality Sensor-AM1008W-16

After-Sales Services and Consultancy Cubic Sensor and Instrument Co.,Ltd. Tel: +86 (0)27 81628827 Fax: +86 (0)27 81628821 Add: Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China E-mail: [email protected]

 Open the catalog to page 16

All Cubic Sensor and Instrument Co.,Ltd catalogs and technical brochures

  1. About Cubic

    1  Page

  2. Gasboard-7020

    4  Pages

  3. Gasboard-7500

    7  Pages

Archived catalogs

  1. RHB Series

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.