Group: Cubic
Catalog excerpts

USERS MANUAL Infrared Methane Gas Sensor For safety and alarming Wuhan Cubic Optoelectronics Co.Ltd Add: Fenghuang No.3 Road, Fenghuang Industrial Park Eastlake Hi-tech Development Zone Wuhan 430205, China Tel:86-27-81628831 Fax: 86-27-87405251
Open the catalog to page 1
INFRARED METHANE SENSOR | cubic
Open the catalog to page 2
This product must be used with explosion-proof equipments; the system wiring must comply with the product and the instructions associated with the use of equipment requirements shall not take the wrong terminal. Safety parameters and the maximum content of the equivalent parameter table below: Max input consumption summary ∑Pi(W) Max input current summary ∑Ii(mA) Maximum internal equivalent parameters Li(mH) This product and associated equipment’s connection cables should be protected by a sheath, the shield should be grounded. Users shall not replace the product components; in conjunction...
Open the catalog to page 3
1 Introduction 1.1 Briefing Welcome to use infrared methane gas sensor. It adopts advanced non-dispersive infrared technology and qualified raw materials and parts, which can be integrated in safety and alarming devices, able to be used for environmental monitoring, gas drainage monitoring; chemical, petroleum, metallurgy, oil depots, liquefied gas stations, paint jobs, gas transmission and distribution and other combustible gases, storage, indoor and outdoor use and so easy to leak dangerous places. The sensor has advantages like easy operation, precise measurement and stable performance,...
Open the catalog to page 4
USERS MANUAL Picture is only for reference INFRARED METHANE SENSOR | cubic
Open the catalog to page 5
2. Functions & Operation 2.1Appearane & I/O definition 2.1.1Appearance Power input(ground terminal) Voltage output UART-TX output UART-RX input INFRARED METHANE SENSOR | cubic
Open the catalog to page 6
USERS MANUAL 2.1.3 Digital output interface circuit (reference ] Digital output: TTL electrical level, voltage signal is 0 or 2.5v, 1. Connect with PC :pay attention to level switching when connecting external circuit, computer circuit is illustrated below: 2. Connect with CPU(SCM), baud rate: 9600bps A. If CPU is powered by 2.5 - 3.3V, CH4 gas sensor can be connected directly and make communication. Note: RXD of CH4 gas sensor is connected to TXD of CPU. TXD of CH4 gas sensor is connected to RXD B. If CPU is 5V, please change PWL. Here is for reference: (Or use the other PWL conversion...
Open the catalog to page 7
2.2Operation 2.2.1 Power on Be sure the preparation is OK before Power on: Power connection is right I/O ports connection is right 2.2.2 Power off Sensors must be power off under the standby mode (power off is not allowed when you operating zeroing and calibration). Before power off, the gas sensor should be in the measuring status in the fresh air for 1~3 minutes to ensure the gas cell emptying and avoid possible measurement error by the rest gas or dust. 2.2.3 Measurement After warm up, the gas sensor is standby. In this case, the sensor can measure CH4 concentration in existing...
Open the catalog to page 8
4. The length of command byte is [LB]+3. Command Format: [LB] byte length followed does not include CS [DF] parameter items with command, optional a. When the command is implemented correctly, it responses [LB] byte length followed does not include CS [DF] parameter items with command, optional b. When the command is not implemented correctly, it responses [NAK]=0X06 Command is not implemented correctly [LB]=2 byte length followed does not include CS [EC] the error code that command is not implemented correctly 1 Order length is wrong 3 Can't implement this command under current status....
Open the catalog to page 9
1. Look up measurement result Send11 01 01 ED Response[ACK] 05 01 [DF1] [DF2] [ST1] [ST2] [CS] FunctionLook up measurement result. Remarks 1).Gas 1 concentration = DF1*256+ DF2/ (corresponding multiple) 2).[ST] means status of system, which give the information of working status of it. For example: to check whether it need zeroing, sampling signal is correct, users options. 2. Look up voltage result Send11 02 02 [TVM] EB Response[ACK] 0A 02 [TVM] [FV1] [FV2] [FV3] [FV4] (refVpp) (testVpp) [CS] FunctionLook up voltage result. Remarks 1). [TVM] gas measurement voltage. 2). [FV1] [FV2] [FV3]...
Open the catalog to page 10
Remark 1. Reset users calibration data to factory calibration data 2. [GasNum] means indicator bit of gas calibration. 6. Software version check Send11 01 1E D0 Response [ACK] 0C 1E [CH1] [CH2] [CH3] [CH4] [CH5] [CH6] [CH7] [CH8][CH9][CH10][CH11][CH12] [CS] Function to check software version Remark [CHx] is ASCLL II code. 7. Series number check Send11 01 1F CF ResponseACK] 0B 1FSN1 SN2 SN3 SN4 SN5[CS] Function to check the series number of the bench Remark SNn is from 0-9999, five integer consists of 20 bits series number 8. Gas measurement property Check Send11 01 0D [CS] Response[ACK] 06...
Open the catalog to page 11
ADD Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China FAX86-27-87401159 Http://www.gassensor.com.cn E-mail:info@gassensor.com.cn INFRARED METHANE SENSOR | cubic
Open the catalog to page 12All Cubic Sensor and Instrument Co. catalogs and technical brochures
-
Cubic TDLAS CH4 Sensor
4 Pages
-
Gasboard-7500H-OPC
13 Pages
-
NDIR CO2 Sensor Module-CM1106LS
18 Pages
-
Laser Particle Sensor-PM2008M-M
22 Pages
-
Laser Particle Sensor-PM2012
19 Pages
-
Test Instruction of AM4100-I
7 Pages
-
Test Instruction of AM1008W
7 Pages
-
Test Instruction of PM5000
7 Pages
-
Test Instruction of PM1006
8 Pages
-
Test Instruction of CM1107T
7 Pages
-
Test Instruction of CM1107BN
8 Pages
-
Test Instruction of PM3006T
7 Pages
-
Test Instruction of PM2009
8 Pages
-
Test Instruction of CM1106SH
8 Pages
-
Test Instruction of CM1107
8 Pages
-
Test Instruction of CM1106S
8 Pages
-
Test Instruction of CM1106LS
8 Pages
-
Laser Particle Sensor-PM2008
21 Pages
-
Laser Particle Sensor-PM2009
20 Pages
-
Laser Particle Sensor-PM2105-M
20 Pages
-
NDIR CO2 Sensor Module-CM1106S
18 Pages
-
Gas Sensor Line-up
1 Pages
-
About Cubic
1 Pages
-
CEMS Solution - Gasboard 9050
22 Pages
-
NDIR CO2 Sensor Modules
7 Pages
-
Gasboard-7020
4 Pages
-
Gasboard-7500
7 Pages
-
Mainstream ETC02 module
5 Pages
-
Gasboard 3400P
5 Pages
-
Analyzer Gasboard 3800P
6 Pages
-
LANDFILL APPLICATIONS
8 Pages
Archived catalogs
-
Air quality monitor AM7000
11 Pages
-
RHB Series
8 Pages
-
Ultrasonic Flow meter 7200
1 Pages
-
Syngas portable analyzers
4 Pages
-
Opacity meter
1 Pages
-
Infrared Methane gas sensor
3 Pages