1. Catalogs
  2. Cubic Sensor and Instrument Co.,Ltd
  3. Infrared Carbon Dioxide gas sensor

Infrared Carbon Dioxide gas sensor

Infrared Carbon Dioxide gas sensor

Infrared Carbon Dioxide gas sensor

Product catalog summary
Infrared Carbon Dioxide Gas Sensor Overview
Features:
  • Measuring range options: 0-0.5% or 0-10% volume.
  • Working voltage: DC 3.5V to 6V.
  • Working current: 85 mA.
  • Operating temperature range: -25℃ to 85℃.
  • Signal output: Digital and analog (0.4V to 2.0V).
  • Accuracy: 1%FS for 0-1%, 2%FS for 0-5%.
  • Dimensions: Φ20 x 19mm (excluding pins).
  • Output interface: 5-pin output.
Specifications:
  • Working voltage: 3.5-6VDC.
  • Working current: 75-80mA.
  • Output voltage: 0.4V-2VDC.
  • Measurement range: 0-0.5% or 0-10% volume.
  • Resolution: 0.001% for 0-0.5%vol, 0.01% for 0-10%vol.
  • Warm-up time: 30 seconds.
  • Response time (T90): Less than 25 seconds.
  • Zero repeatability: ±1%FS at 20℃.
  • Sensitivity repeatability: 0.1% for 0-5%vol, 2% for 5-100%vol at 20℃.
  • Zero drift: 1% per month.
  • Operating temperature: -20℃ to 55℃.
  • Storage temperature: -20℃ to 55℃.
  • Digital signal format: 8 data bits, 1 stop bit, no check bit.
  • Standard baud rates: 9600bps, 19200bps, 38400bps.
  • Dimensions: Φ20 x 19mm (excluding pins).
  • Output pin: 5-pin.
  • Lifespan: Greater than 5 years.
  • Weight: 15g.
Installation and Connection:
  • Digital output uses TTL electrical level with a voltage signal of 0 or 2.5V. Ensure proper level switching when connecting to external circuits.
  • Baud rate for digital communication: 9600bps.
  • Data format: 8 data bits, 1 stop bit, no check bit.
  • Power supply requirement: DC 3.5V to 6V.
Manufacturer Information:
  • Wuhan Cubic Optoelectronics Co., Ltd.
  • Contact: 0086-27-87405251 Ext. 8018 / 8019
  • Email: [email protected]
  • Website: www.gassensor.com.cn
  • Address: Floor 10, Building 6, SBI Street, Hongshan District, Wuhan 430074, Hubei Province, P.R. China.
See more

Catalog excerpts

Infrared Carbon Dioxide gas sensor-1

Infrared Carbon Dioxide Gas vV VVulun CuUlc Optoelectronic* Co,. Ltd. Working voltage : DC3.5V - 6V , working Signal output : digital output, analog output Output interface : 5-pin output

 Open the catalog to page 1
Infrared Carbon Dioxide gas sensor-2

vV VVulun CuUlc Opfaelettfante* Co,tltd

 Open the catalog to page 2
Infrared Carbon Dioxide gas sensor-3

WuUara Cubic Optoelectronic* Co.. Ltd. Installation Dimension

 Open the catalog to page 3
Infrared Carbon Dioxide gas sensor-4

vV VVulun CuUlc Optoelectronic* Co,.Ltd. Digital outputQ TTL electrical levelQ voltage signal is 0 or 2.5vQ pay attention to level switching when connecting external circuit, computer circuit is illustrated belowO Check bitn null Email: [email protected] Add:FloorlO,Building 6,SBI Street, Hongshan District, Wuhan 430074 , Hubei Province, P.R.China I illlPIl IIII rlill II IlilllTirci FiaitllIIlITiririlllll'irilli CITIil' r

 Open the catalog to page 4