Gasboard-7500H-OPC

Gasboard-7500H-OPC
1 / 13 PagesView full catalog

Gasboard-7500H-OPC

Product catalog summary
Product Overview
The Gasboard-7500H-OPC is an ultrasonic flow sensor designed for measuring gas flow in binary gases. It is based on the Gasboard-7500 ultrasonic oxygen sensor module and is known for its quick response, high accuracy, and stability. The sensor is suitable for digital gas analysis, particle counters, and air monitoring equipment.

Key Features
  • Measures flow rate of binary gas
  • Full scale matrix temperature and humidity compensation
  • Small size, quick response, stable, high accuracy
  • Long lifespan, self-calibration, maintenance-free
  • RoHS, REACH, CMC, EMC, CE certified

Working Principle
The sensor uses the time difference method to measure the flow rate by detecting the time difference of ultrasonic waves propagating in the fluid.

Specifications
  • Detection Range: 0~5L/min
  • Accuracy: ±3% or ±0.06L/min
  • Resolution: 0.01L/min
  • Response Time: <0.3S
  • Operating Conditions: -20~60℃; 0~95%RH
  • Voltage: DC 4.75-12.6V
  • Communication Interface: UART_TTL (3.3V)
  • Product Size: W80*H22*D25 mm
  • Life Span: ≥5 Years

Pin Definition
The sensor has specific pin definitions for power supply and communication, detailed in the document.

Communication Protocol
The sensor uses a UART communication protocol with a baud rate of 9600. It supports active sending and request-response modes for data transmission.

Reliability Testing
The sensor undergoes various tests including flow performance, temperature storage, operation tests, and vibration tests to ensure reliability.

Packing Information
The sensor is packed in anti-static plastic trays with specific dimensions and quantities per carton.

User Attention
Users are advised to install the sensor away from heat sources, avoid using it in extreme conditions, and not to disassemble it privately.

Contact Information
For consultancy and after-sales service, contact details including phone number, address, and email are provided.
See more

Catalog excerpts

Gasboard-7500H-OPC-1

SPECIFICATION Product Name: Ultrasonic Flow Senor Version: V1.0 Date: August 01, 2020

 Open the catalog to page 1
Gasboard-7500H-OPC-2

Content First Edition

 Open the catalog to page 2
Gasboard-7500H-OPC-3

Ultrasonic Flow Sensor Module Gasboard-7500H-OPC Applications  Digital Gas Analysis and Detection Instrument Particle Counter Measurement the Flow of Clean Gas Description Gasboard-7500H-OPC ultrasonic flow sensor is an economical sensor for measuring gas flow in binary gases. Based on the mature gasboard-7500 ultrasonic oxygen sensor module, this sensor has outstanding characteristics of quick response, high accuracy, great stability, no drift, etc. Gasboard-7500H-OPC sensor has full scale matrix humidity compensation, not affected by humidity. This product is very suitable for digital gas...

 Open the catalog to page 3
Gasboard-7500H-OPC-4

Specification Ultrasonic Flow Sensor Specification Detect Principle Ultrasonic Technology Detection Range Detection Accuracy Response Time Work Condition Storage Condition Work Voltage Average Work Current Communication Interface Product Size Life Span Remark① Working condition flow, under current temperature, volume flow under current pressure.

 Open the catalog to page 4
Gasboard-7500H-OPC-5

Table 1. Connector Pin Definition J2 NO 4.75-12.6V, External Power Supply Input Pin 4.75-12.6V, External Power Supply Input Pin Power Supply Input Power Input Table 2. Connector Description Port

 Open the catalog to page 5
Gasboard-7500H-OPC-6

Reference Circuit Application Scenarios: UART 3.3V Output Drawing 2 UART Communication Connection Circuit

 Open the catalog to page 6
Gasboard-7500H-OPC-7

Communication Protocol UART Communication Protocol 1. The protocol data are hexadecimal data. For example, “46” is [70] in decimal; [xx] is single byte data(unsigned,0-255); In double byte, the high byte is in front of low byte; Baud Rate: 9600, Data Bits: The default is active sending, and the sending cycle is 0.5 seconds. If you need to read more other data, send the corresponding command directly to the host, and the host responds immediately. Serial Communication Protocol Format PC Send Format Start Symbol Protocol Format Description Description Protocol Format Start Symbol PC sending is...

 Open the catalog to page 7
Gasboard-7500H-OPC-8

Communication Protocol Response Example: Response: Instruction: Hexadecimal Convert into Decimal: Gas Flow Value=(1*256+27)/100=2.83 (L/min) Temperature Value= (0*256+194)/10=19.4 (℃) 4.2 Read the Software Version Number Send: 11 01 1E D0 Response: 16 09 01 DF1-DF8 [CS] Function: Read the software version number Instruction: DF1-DF8 refers to the ASCII code of particular version number For example: When module version number is 0.02.016, response data: Hexadecimal Convert into ASCII Code: 4.3 Inquiry Instrument Serial Number Send: 11 01 1F CF Response: 16 0B 1F(SN1)(SN2)(SN3)(SN4)(SN5) [CS] Function:...

 Open the catalog to page 8
Gasboard-7500H-OPC-10

Product Code Instruction Product Type OPC: Product Type Structure Type H: Structure Type ※ Product Application 7500: Civilian Areas ※ Product Category Gasboard: Ultrasonic Gas Sensor

 Open the catalog to page 10
Gasboard-7500H-OPC-11

Reliability Testing Item Indoor temperature requirement: 25±2℃, humidity(50±10)%RH, after the sensor connect Make new tests in different oxygen with serial port and power on, switch over the flow in 3L/min、5L/min、8L/min respectively criterion. to make measurement of oxygen concentration and accuracy. flow, all can meet deviation Flow Performance Storing the sensor for 96H with no power under -20℃±2℃ environment condition, then After staying under normal temperature condition for 2 hours, the test the measuring deviation under normal temperature condition. Indoor temperature requirement: -10±2℃,...

 Open the catalog to page 11
Gasboard-7500H-OPC-12

Packing Information Carton Dimension Packing Material Anti-static Plastic Tray

 Open the catalog to page 12
Gasboard-7500H-OPC-13

User Attention Please pay attention to below: (1) Install the sensor as far away as possible from the heat source and heat dissipation outlet of the compressor, and install the sensor as close as possible to the air outlet. (2) In order to ensure reliability and long service life, do not use or store the sensor in a place where the temperature is higher than the rated temperature, and do not use the sensor in an environment where the voltage is higher than the rated voltage of the sensor. (3) Without necessary compensations, please do not use the sensor in the environments of high humidity water...

 Open the catalog to page 13

All Cubic Sensor and Instrument Co.,Ltd catalogs and technical brochures

  1. About Cubic

    1  Page

  2. Gasboard-7020

    4  Pages

  3. Gasboard-7500

    7  Pages

Archived catalogs

  1. RHB Series

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.