UltraCam LD 500/510

UltraCam LD 500/510

UltraCam LD 500/510

Product catalog summary
Overview: The document provides detailed information on the UltraCam LD 500/510, a device designed for detecting and visualizing leaks using ultrasonic technology. It highlights the features, specifications, and benefits of the device, as well as the accessories and software available for enhanced functionality.
Specifications: The LD 500/510 operates at a frequency of 40 kHz ± 2 kHz and includes a 3.5" touch screen display. It features a laser with a wavelength of 630-660 nm and an output power of less than 1 mW. The device is powered by internal rechargeable Li-Ion batteries, offering approximately 9 hours of continuous operation. It is equipped with a USB interface and a 16 GB SD memory card for data logging.
Features: The UltraCam LD 500/510 uses 30 MEMS microphones to visualize leaks directly in the image, even in noisy environments. It includes a unique laser distance measurement for automatic cost determination and is capable of multi-user operation through a cloud solution. The device is ergonomic, lightweight, and designed for fatigue-free work.
Procedures: Users can enter compressed air costs in the unit and define leakage locations, remedial measures, and spare parts required on-site. The device allows for paperless documentation and the creation of ISO 50001 compliant reports using the CS Leak Reporter software.
Accessories: The set includes a focus tube, sound-proof headset, holster with shoulder strap, and various goosenecks for detecting leaks in difficult-to-access areas. A parabolic mirror is available for pinpoint detection of small leaks at long distances.
Software: The CS Leak Reporter software provides detailed ISO 50001 reports and supports spare parts management and continuous improvement documentation. It is available as a PC solution or a cloud-based solution for real-time, paperless documentation.
Cost Calculation: The document includes a table showing leakage costs per year based on pressure and leak size, calculated with compressed air costs of 1.9 ct/Nm³.
Technical Data: The LD 500/510 is designed to operate in temperatures ranging from -5 to +50 °C and complies with EMC standards (DIN EN 61326). It features auto-level sensitivity adjustment to eliminate ambient noise and has a minimum sensitivity of 0.1 l/min at 6 bar from a 5 m distance.
See more

Catalog excerpts

UltraCam LD 500/510-1

Leakage UltraCam LD 500/510 – Visualises the leaks directly in the image Enormous time saving compared to classic leak detectors 30 MEMS microphones create the image of the leaks Brightness sensor activates LEDs in dark surroundings Available as an upgrade for LD 500/510 NEW: Multi-user capable through cloud solution NEW: Unique laser distance measurement for automatic cost determination Find out your leakage rate (l/min or cfm) and potential savings (€ /year). Currency can be set as required Photograph leaking parts Paperless documentation. Enter everything into the device on site: Define the leakage location as well as the remedial measures and spare parts required The LD 500 meets the requirements of class 1 instruments for the “Standard Test Method for Leaks Using Ultrasonic” (ASTM Int. - E1002-05) Create a report in accordance with ISO 50001 Fatigue-free work – ergonomic, one-hand operation –

 Open the catalog to page 1
UltraCam LD 500/510-2

Leakage Display and function in detail The UltraCam LD 500/510 uses 30 MEMS microphones to calculate and visualise the ultrasound image. In addition, the device makes inaudible ultrasound audible Advantage over the classic leak detectors: Visual representation of the leakage in the live image, even in noisy environments during production To determine the leakage rate, the user aims the laser directly at the leakage. Leakage, laser and red circle must be on top of each other in the image. Then, the leakage rate in l/min or cfm and the costs in €/year are determined exactly. The distance is measured...

 Open the catalog to page 2
UltraCam LD 500/510-3

Leakage Easy documentation in the LD 500 / UltraCam LD 500 directly on site Entering the compressed air costs in the unit Depending on the electricity costs, the costs per 1000 m³ (or per 1000 cf) can be freely entered in any currency Define the location The location of each leak can be stored: Company / building / location Efficiency and clarity also for elimination of leaks. Definition of the necessary spare parts and maintenance work already on site. Spare parts list in the device The software can be used to transfer a custom spare parts list to the device. The device offers an intelligent...

 Open the catalog to page 3
UltraCam LD 500/510-4

Leakage Use the reporting software to quickly and efficiently produce an ISO 50001 report CS Leak Reporter – cloud solution CS Leak Reporter – PC solution Ideal for leak detection service providers and for companies/ major corporations with multiple locations. Creates detailed ISO 50001 reports. Provides an illustrated overview of the leaks found and their savings potential. Measures for elimination, including status display, can be defined for every leak – license for two computers • Each “user” in the leakage search team can be assigned a role (e.g. leakage search, leakage repair, monitoring,...

 Open the catalog to page 4
UltraCam LD 500/510-5

Leakage Accessories included in the set: Headset The noise-proof headset enables leak detection even in an extremely loud environment. The ambient noise is faded out, and the leakage (inaudible ultrasonic sound) is transformed into an audible signal Holster with shoulder strap For the LD 500/510, enables ergonomic and safe work Focus tube with focus tip For pinpoint detection of the smallest leaks in confined spaces Professional accessory – parabolic mirror By focusing the ultrasonic waves in the parabolic mirror, even the smallest leaks of 0.8 l/min (approx. € 8 p.a.) can be located with pinpoint...

 Open the catalog to page 5
UltraCam LD 500/510-6

Leakage Software DESCRIPTION CS Leak Reporter V2 Creates detailed ISO 50001 reports. Provides an illustrated overview of the leaks found and their savings potential. Measures for elimination, including status display, can be defined for every leak – license for two computers New functions: - Simple spare parts management - Histogram functions for documenting continuous improvement in accordance with ISO 50001 on the company or building level DESCRIPTION CS Leak Reporter V2 – additional licence for one computer DESCRIPTION CS Leak Reporter – cloud solution Basic package: Browser-based access to...

 Open the catalog to page 6
UltraCam LD 500/510-7

Leakage Calculation Costs per year Size of leak – diameter (mm) Pressure 3 bar Table: Leakage costs in one year with 24-hour operation 365 days per year calculated with compressed air costs of 1.9 ct/Nm³. TECHNICAL DATA OF THE LD 500 / LD 510 Operating frequency: 3.5 mm stereo jack for headset, power supply socket for connecting an external charger Wavelength: 630…660 nm Output power: < 1 mW (laser class 2) Data logger: 16 GB SD memory card (100 million values) Power supply: Internal rechargeable Li-Ion batteries, approx. 9 h continuous operation, 4 h charging time Operating temperature: Auto...

 Open the catalog to page 7

All CS Instruments GmbH & Co. KG catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry