Catalog excerpts
Flow VA 570 - Inline flow meter Version with pipe thread R thread or NPT thread Flange version VA 570 is supplied with an integrated measuring section. The measuring sections are available in flanged version or with R resp. NPT thread. A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory). The screwing with a centring device is designed such that the sensor is positioned accurately in the centre when screwing it into the measuring section; furthermore, it enables an exact positioning in the flow direction. This eliminates unnecessary measuring faults. Approvals: II 2 G Ex db IIC T4 Gb II 2 D Ex tb IIIC T90 °C Db Special measurement technology features: • 4 values on the display: Flow, total consumption, velocity, temperature. Units freely adjustable • All measured values, settings such as gas type, inner diameter, serial number and so on can be accessed via Modbus-RTU The sensor can be removed and cleaned • Comprehensive diagnostic functions readable on the display or remote access via Modbus such as calibration cycle, error codes, serial number • Notification in case of exceeding the calibration cycle • Standard version accuracy 1.5% of m.v. ± 0.3% of f.s. • Precision version accuracy 1.0% of m.v. ± 0.3% of f.s • Measuring span of 1 : 1000 (0.1 up to 224 m/s) • Configuration and diagnosis via display, hand-held device PI 500, PC service software on-site • Gas type (air, nitrogen, oxygen, argon and so on) freely adjustable via PC service software or external device DS 400, DS 500, PI 500 Special mechanical features: • Robust impact-proof aluminium die cast housing for the outdoor area IP 67 • All wetted parts made from stainless steel 1.4571 • On request with DVGW approval for natural gas (up to 16 bar) • Pressure range up to 16 bar, special version up to 40 bar • Temperature range up to 180 °C • Reference conditions °C and mbar/hPa freely adjustable • No moveable parts, no wear • Zero-point adjustment, leak flow volume suppression • Sensor tip very robust, easy to clean • Pressure loss negligible • Housing rotatable, display rot
Open the catalog to page 1Flow Measuring range - Flow VA 570 1/2″ Reference conditions DIN 1945 / ISO 1217: 20 °C, 1000 mbar Low-Speed (50 m/s) Setting to DIN 1343: 0 °C, 1013.25 mbar Low-Speed (50 m/s) Optional: Connection to different Bus systems There are different options available for connection to modern Bus systems: • Ethernet interface (Modbus-TCP) / PoE • M-BUS • Modbus-RTU • Profibus DP interface (in process) • Profinet interface (in process) • HART (in process) Ethernet Modbus TCP M12 Ethernet port, x-coded For further accessories refer to pages 102 to 106
Open the catalog to page 2Flow VA 570 - Inline flow meter Example order code VA 570: 0695 0570_A1_B1_C1_D1_E1_F1_G1_H1_I1_J1_K1_L1_M1_R1 Surface conditon Male thread measuring section A1 A2 A3 R male thread NPT male thread Flange DIN EN 1092-1 Flange ANSI 16.5 Class 150 lbs Flange ANSI 16.5 Class 300 lbs Accuracy class with integrated display without display 2 units 4...20 mA analogue output (electrically isolated), pulse output, RS 485 (Modbus-RTU) 1 x 4…20 mA analogue output (not electrically isolated), pulse output, RS 485 (Modbus-RTU) Ethernet interface (Modbus / TCP), 1 x 4...20 mA analogue output (not...
Open the catalog to page 3Flow Order no. VA 570 DESCRIPTION VA 570 flow meter with integrated 1/2" measuring section VA 570 flow meter with integrated 3/4" measuring section VA 570 flow meter with integrated 1" measuring section VA 570 flow meter with integrated 1 1/4" measuring section VA 570 flow meter with integrated 1 1/2" measuring section VA 570 flow meter with integrated 2" measuring section VA 570 flow meter with integrated DN 15 measuring section with flange VA 570 flow meter with integrated DN 20 measuring section with flange VA 570 flow meter with integrated DN 25 measuring section with flange VA 570 flow...
Open the catalog to page 4VA 570 - with flange Flange DIN EN 1092-1 Pipe size DN 15 DN 20 VA 570 - Threaded version Connection thread *Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) o
Open the catalog to page 5All CS Instruments GmbH & Co. KG catalogs and technical brochures
-
Data sheet FA 510
1 Pages
-
Data sheet - CS Network - EN
3 Pages
-
Data sheet - IAC 500 - EN
1 Pages
-
Data sheet - PTS 500 - EN
1 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
UltraCam LD 500/510
7 Pages
-
Data sheet DS 52 Set - EN
1 Pages
-
Data sheet - VA 550 - EN
4 Pages
-
Data sheet - VD 500 - EN
2 Pages
-
Data sheet - DS 500 - EN
4 Pages
-
Data sheet - VX 570 - EN
4 Pages
-
Data sheet - DS 400 - EN
4 Pages
-
Data sheet - VU 570 - EN
3 Pages
-
Data sheet - VA 521 - EN
2 Pages
-
Data sheet - VA 525 - EN
2 Pages
-
Data sheet FA 550 - EN
2 Pages
-
Data sheet - VA 520
4 Pages
-
Data sheet - PI 500
2 Pages
-
Data sheet - DS 400 Set
2 Pages
-
Data sheet FA 500
2 Pages
-
Data sheet - VA 500
2 Pages
-
Data sheet LD 450
2 Pages
-
Data sheet - OILCHECK mobile
6 Pages
-
Data sheet LD 500
8 Pages
-
Data sheet FA 515 Ex
1 Pages
-
Data sheet LD 400
2 Pages
-
Data sheet LD 500
4 Pages
-
Data sheet DP 500
4 Pages
-
Data sheet FA 510
2 Pages
-
Data sheet - VA 570
12 Pages
-
Data sheet - DS 400 mobile
8 Pages
-
Data sheet - DS 500
10 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
Data sheet - DS 500 mobile
8 Pages
-
Data sheet DP 400 mobile
2 Pages
-
Data sheet - PI 500
7 Pages
-
Data sheet - VA 500/520
9 Pages