Catalog excerpts
Pressure PTS 500 – Measures pressure and temperature in the process Special features: • 2 in 1 sensor: Pressure and temperature • Wettedparts made of stainless steel for universal use in gases and liquids • Easy integration into control systems, process control technology and energy management systems via digital interfaces • Modbus-RTU, Ethernet or M-Bus interface • Alarm relay – limit value adjustable via buttons (max 60 VDC, 0.5 A) • Optional: 2 x 4...20 mA analogue output, 2 x alarm relays for pressure and temperature Example order code PTS 500: 0694 7000_A1_B1_C1 Signal output option 1 x 4...20 mA analogue output (galvanically not isolated), A1 alarm relay, RS 485 (Modbus-RTU) 2 x 4...20 mA analogue output (galvanically not isolated), A2 2 x alarm relays, RS 485 (Modbus-RTU) Ethernet interface (Modbus/TCP), 1 x 4…20 mA A3 analogue output (galvanically not isolated), RS 485 (Modbus-RTU) Ethernet interface PoE (Power over Ethernet) A4 (Modbus/TCP), 1 x 4...20 mA analogue output (galvanically not isolated), RS 485 (Modbus-RTU) M-Bus, 1 x 4...20 mA analogue output (galvanically not A5 isolated), alarm relay, RS 485 (Modbus-RTU) Pressure measuring ranges B1 B2 B3 B4 B5 TECHNICAL DATA of PTS 500 Temperature measuring range: Accuracy: Pressure measuring range: Accuracy: See order code ± 0.5% off f.s.(at 20°C) Voltage supply: PTS 500 sensor for measuring of pressure and temperature Further accessories: Connection cable for probes 5 m with open ends Connection cable for probes 10 m with open ends Ethernet connection cable length 5 m, M12 plug x-coded (8 pin) to RJ 45 plug Ethernet connection cable length 10 m, M12 plug x-coded (8 pin) to RJ 45 plug 18...36 VDC via SELV supply, 5W or Power over Ethernet (IEEE802.3af: Class 2 (3.84W 6.49W) Protection class of housing: Operating temperature: Ambient temperature: Storage temperature: Pressure [hPa, mbar, bar, psi,...] Temperature [
Open the catalog to page 1All CS Instruments GmbH & Co. KG catalogs and technical brochures
-
Data sheet FA 510
1 Pages
-
Data sheet - CS Network - EN
3 Pages
-
Data sheet - IAC 500 - EN
1 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
UltraCam LD 500/510
7 Pages
-
Data sheet - VA 570 - EN
5 Pages
-
Data sheet DS 52 Set - EN
1 Pages
-
Data sheet - VA 550 - EN
4 Pages
-
Data sheet - VD 500 - EN
2 Pages
-
Data sheet - DS 500 - EN
4 Pages
-
Data sheet - VX 570 - EN
4 Pages
-
Data sheet - DS 400 - EN
4 Pages
-
Data sheet - VU 570 - EN
3 Pages
-
Data sheet - VA 521 - EN
2 Pages
-
Data sheet - VA 525 - EN
2 Pages
-
Data sheet FA 550 - EN
2 Pages
-
Data sheet - VA 520
4 Pages
-
Data sheet - PI 500
2 Pages
-
Data sheet - DS 400 Set
2 Pages
-
Data sheet FA 500
2 Pages
-
Data sheet - VA 500
2 Pages
-
Data sheet LD 450
2 Pages
-
Data sheet - OILCHECK mobile
6 Pages
-
Data sheet LD 500
8 Pages
-
Data sheet FA 515 Ex
1 Pages
-
Data sheet LD 400
2 Pages
-
Data sheet LD 500
4 Pages
-
Data sheet DP 500
4 Pages
-
Data sheet FA 510
2 Pages
-
Data sheet - VA 570
12 Pages
-
Data sheet - DS 400 mobile
8 Pages
-
Data sheet - DS 500
10 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
Data sheet - DS 500 mobile
8 Pages
-
Data sheet DP 400 mobile
2 Pages
-
Data sheet - PI 500
7 Pages
-
Data sheet - VA 500/520
9 Pages