Data sheet - PC 400 mobile
6Pages

{{requestButtons}}

Catalog excerpts

Data sheet - PC 400 mobile - 1

Compressed air quality Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Residual oil content measurement – OIL-Check 400 For permanent and highly precise measurement of the vaporous residual oil content from 0.001 mg/m³ to 2.5 mg/m³. Due to the deep detection limit of 0.001 mg/m³ the compressed air quality class 1 (ISO 8573) can be monitored. Particle counter PC 400 The highly precise optical particle counter PC 400 measures particles from a size of 0.1 μm and is therefore suitable for monitoring of the compressed air quality class 1(ISO 8573). Moisture – dew point sensor FA 510 FA 510 measures the pressure dew point down to -80 °Ctd. Also in this case the continuous measurement takes care that alert is triggered immediately if the compressed air dryer breaks down. DS 500 - the intelligent chart recorder of the next generation. The curve progressions from the beginning of the measurement can be viewed by The centerpiece of comressed air quality measurement is the chart recorder DS 500. It measure and documents the measured data of the sensors for residual oil content, particles and moisture. The measured values are indicated on a 7“ color screen. data logger stores the measured values safely and reliably. The threshold value can be freely entered for each measured parameter. 4 alarm relays are available for automatic alarm in case of an exceeding of the threshold values. Optionally DS 500 can be upgraded with up to 12 sensor inputs. For connection to a PLC DS 500 has an Ethernet interface as well as a RS 485 interface. The communication is done via the Modbus protocol. Extract from ISO 8573-1 - threshold values Solids Maximum number of particles per m³ Pressure dew point vapor Totalshare in oil (liquid aerosol and mist) According to determination by the instruments user, more severe requirements than Class 1

Open the catalog to page 1
Data sheet - PC 400 mobile - 2

DS 500 mobile - intelligent chart recorder with 4 sensors inputs 0500 5012 CS Basic - data evaluation in graphic and table form - readout of the measured 0554 8040 data via USB or Ethernet. License for 2 working places OIL-Check 400 - residual oil measurement of the vaporous residual oil content from 0.001...2.5 mg/m3, 3...16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0.10 Volt for connection to external chart recorders Mobile transport trolley including roles (outer dimensions: 1.0 x 0.7 x 0.35...

Open the catalog to page 2
Data sheet - PC 400 mobile - 3

The advantages at a glance: • Permanent, highly precise residual oil measurement (oil vapour) with PID sensor (photo-ionic-detector) • Ideal for mobile measurement: The PID sensor is ready for measurement within about 30 minutes • Long-term stable measuring results due to automatic zero-point calibration. The integrated mini catalyst reliably generates a defined reference gas for zero-point calibration • Contrary to measuring systems which generate the ”zero air“ resp. reference gas by means of active carbon filters and which are there fore depending on the ageing and the saturation of...

Open the catalog to page 3
Data sheet - PC 400 mobile - 4

Compressed air qualityOIL-Check 400 - stationary solution with DS 400 Order no. OIL-Check 400 - residual oil content measurement of the vaporous residual oil 0699 0070 content from 0.001...2,5 mg/m3, 3...16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0.10 Volt for connection to an external chart recorder Option: DS 400 chart recorder integrated in the OIL-Check 400 Z699 0071 Sampling system consisting of %“ ball valve (oil- and grease-free), 1 m stainless steel tube 6x1 mm (oil- and...

Open the catalog to page 4
Data sheet - PC 400 mobile - 5

Compressed air qualityParticle counter PC 400 and DS 400 DS 400 shows all 3 measuring channels according to ISO 8573-1 Particle size 0.1...0.5 |jm: Number of particles per m3 Particle size 0.5.1.0 jm: Number of particles per m3 Particle size 1.0.5.0 jm: Number of particles per m3 The advantages at a glance: • Highly precise optical laser particle counter for the use in compressed air and technical gases • Highly precise optics for detection of smallest particles up to 0.1 jm and therefore it is suitable for monitoring of the compressed air class 1 according to ISO 8573-1.The flow rate of...

Open the catalog to page 5
Data sheet - PC 400 mobile - 6

Stationary solution with particle counter PC 400 and DS 400 PC 400 particle counter up to 0.1 pm for compressed air and gases, incl. pressure reducer and calibration certificate Connection cable for probes 5 m, with open ends DS 400 chart recorder with graphic display and touch screen operation Option: Integrated data logger for 100 million measured values Option: Integrated Ethernet and RS 485 interface CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places As an alternative to PC 400 up 0,1 pm: PC 400 particle...

Open the catalog to page 6

All CS Instruments GmbH & Co. KG catalogs and technical brochures