Catalog excerpts
Table: Leakage costs within one year in case of operation 24 h/365 days, calculated with compressed air costs of 1.9 ct/Nm3.
Open the catalog to page 1LD 500/510 is a consistent advancement The new leak meters LD 500/510 with integrated camera and leakage calculation are ideal measuring instruments which help to find and document even smallest leakages (0.1 l/min corresponds to approx. 1 € per year) easily even in far distances. LD 510 is the worldwide first leak meter with an additional freely assignable sensor input for all CS sensors. In addition to the leakage measurement and detection also all necessary measurements with regards to dew point, flow, pressure, and temperature ... can be carried out. Leak detection at: ° Compressed air,...
Open the catalog to page 2Leakage files stored in LD 500 are exported to a USB stick for issuing a report by software 'A If the leakage is found and stored the following data are also stored in the LD 500 and will be available after the export in the CS Leak Reporter software for issuing a report: CStiSmUMEMIS ^ Leak Tags in hardcopies for documentation on-site ° Photo of the leakage point ° Date / time ° Company name / department / machine ° Size of the leakage in liters/min (unit selectable) ° Costs of the leakage per year in € (currency selectable) Detailed reports can be issued via PC software, which can be...
Open the catalog to page 3frequency: Connections: 3.5 mm stereo jack for headset Power supply socket for connecting an external recharger Laser: Wave length: 645...660 nm Output power: < 1 mW (laser class 2) Display: 3,5“ Touch screen Interface: USB interface Data logger 2 GB SD memory card (100 million values) Power supply: Internal rechargea ble Li-Ion batteries approx. 9 h continuous operation, 4 h charging time Ambient temperature: 0...+50°C Auto level: Adapts the sensitivity automatically to the environment and eliminates the ambient noise reliably Sensitivity: min: 0.1 l/min at 6...
Open the catalog to page 4All CS Instruments GmbH & Co. KG catalogs and technical brochures
-
Data sheet FA 510
1 Pages
-
Data sheet - CS Network - EN
3 Pages
-
Data sheet - IAC 500 - EN
1 Pages
-
Data sheet - PTS 500 - EN
1 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
UltraCam LD 500/510
7 Pages
-
Data sheet - VA 570 - EN
5 Pages
-
Data sheet DS 52 Set - EN
1 Pages
-
Data sheet - VA 550 - EN
4 Pages
-
Data sheet - VD 500 - EN
2 Pages
-
Data sheet - DS 500 - EN
4 Pages
-
Data sheet - VX 570 - EN
4 Pages
-
Data sheet - DS 400 - EN
4 Pages
-
Data sheet - VU 570 - EN
3 Pages
-
Data sheet - VA 521 - EN
2 Pages
-
Data sheet - VA 525 - EN
2 Pages
-
Data sheet FA 550 - EN
2 Pages
-
Data sheet - VA 520
4 Pages
-
Data sheet - PI 500
2 Pages
-
Data sheet - DS 400 Set
2 Pages
-
Data sheet FA 500
2 Pages
-
Data sheet - VA 500
2 Pages
-
Data sheet LD 450
2 Pages
-
Data sheet - OILCHECK mobile
6 Pages
-
Data sheet LD 500
8 Pages
-
Data sheet FA 515 Ex
1 Pages
-
Data sheet LD 400
2 Pages
-
Data sheet DP 500
4 Pages
-
Data sheet FA 510
2 Pages
-
Data sheet - VA 570
12 Pages
-
Data sheet - DS 400 mobile
8 Pages
-
Data sheet - DS 500
10 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
Data sheet - DS 500 mobile
8 Pages
-
Data sheet DP 400 mobile
2 Pages
-
Data sheet - PI 500
7 Pages
-
Data sheet - VA 500/520
9 Pages