Data sheet FA 550 - EN

Data sheet FA 550 - EN

Data sheet FA 550 - EN

Product catalog summary
Overview: The FA 550 dew point sensor is designed for outdoor and industrial environments, featuring a robust die-cast aluminium housing with IP 67 protection. It is suitable for measuring dew points in compressed air systems and various gases.
Special Features:
  • Robust, waterproof housing with IP 67 rating.
  • Adjustable alarm relay with a maximum of 60 VDC, 0.5 A.
  • 4...20 mA analogue output, with optional dual outputs for dew point and temperature.
  • Long-term stability and quick adaptation time.
  • Pressure resistance up to 500 bar (optional).
  • New Modbus-RTU and optional Ethernet interfaces.
  • Improved sensor signal resolution and on-site diagnosis capability.
Applications: Suitable for dew point measurement in compressed air systems after dryers and in gases like oxygen, nitrogen, and natural gas.
Operation: The sensor features an integrated display for easy operation, showing dew point and other humidity parameters. Alarm thresholds and hysteresis can be set via display keys.
Technical Data:
  • Measuring range: -80 to +20 °Ctd, with various options.
  • Accuracy: ±1 °C at +50 to -20 °Ctd, ±2 °C at -20 to -50 °Ctd, ±3 °C at -50 to -80 °Ctd.
  • Pressure range: -1 to 50 bar, with special versions up to 350 or 500 bar.
  • Power supply: 24 VDC (10 to 36 VDC).
  • Operating temperature: -20 to 50 °C.
  • Outputs: Modbus-RTU, 4...20 mA, alarm relay.
Ordering Information: The document provides order numbers for the FA 550 sensor and various accessories, including measuring chambers, connection cables, and calibration services.
Options and Customization: The sensor offers various options for display, signal output, bus connection, analogue output scaling, measuring range, maximum pressure, surface condition, sensor protection cap, and connection thread.
See more

Catalog excerpts

Data sheet FA 550 - EN-1

Dew point FA 550 dew point sensor in robust die-cast aluminium housing The FA 550 is ideal for outdoor dew point measurements or rougher industrial environment Special features: • Robust, waterproof die-cast aluminium housing, IP 67 • Alarm relay - limit value adjustable via buttons (max 60 VDC, 0.5 A) • 4...20 mA analogue output • Optional: 2 pieces 4 ... 20 mA analogue output e.g. for dew point and temperature • Extremely stable in the long term • Quick adaption time • Pressure-resistant up to 500 bar (optional) • NEW: Modbus-RTU interface • NEW: Ethernet interface (optional) • NEW: Higher resolution of sensor signal due to the improved evaluation electronics • NEW: Sensor diagnosis on site with a portable device or CS Service Software • Readable via Modbus: pressure dew point [° Ctd.], temperature [° C], rel. humidity [% RH], abs. humidity [g/m³], degree of humidity [g/kg], moisture content V/V [ppmV/V], partial vapour pressure [hPa], atmospheric dew point [° Ctd.atm] APPLICATON: • Dew point measurement in the compressed air after adsorption dryers/membrane dryers and refrigeration dryers • Residual moisture measurement / dew point measurement in gases such as: oxygen, nitrogen, argon, hydrogen, natural gas, biogas ... Easy operation via the keys on the display The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages. The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered. The 4…20 mA analogue output can be scaled freely or also allocated to one further parameter, e. g. g/m³. After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desi

 Open the catalog to page 1
Data sheet FA 550 - EN-2

Dew point Example order code FA 550: 0699 0550_A1_B1_C1_D1_E1_F1_G1_H1_I1 Scaling analogue output Option Signal output / Bus connection without display Stainless steel sintered cap (~ 50 μm) perforated stainless steel cap Connection thread with integrated display Standard scaling -80…+20 °Ctd. (-112 to 68 °F) -20…+50 °Ctd. (-4 to 122 °F) -40…+30 °Ctd. (-40 to 86 °F) -60…+30 °Ctd. (-76 to 86 °F) -80…+20 °Ctd. (-112 to 68 °F) (scaling 4…20 mA = -100…+20 °Ctd.) -80…+20 °Ctd. (-112 to 68 °F) (scaling 4…20 mA = -110…+20 °Ctd.) 2 x 4 ... 20 mA analogue output (electrically isolated), alarm relay, RS...

 Open the catalog to page 2

All CS Instruments GmbH & Co. KG catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry