Data sheet FA 515 Ex

Data sheet FA 515 Ex

Product catalog summary
Special Features:
  • Robust design
  • Pressure-tight up to 500 bar
  • Long-term stable humidity sensor, approved for years
  • 4...20 mA analogue output in 2-wire technology
  • Adjustable parameters via software: % RH, g/m³, mg/m³, ppm V/V, g/kg
  • New: Higher resolution of the sensor signal due to improved evaluation electronics
Approvals:
  • II 2G Ex ib IIC T4 Gb: Zone 1, gas, intrinsically safe, Temp. 135°C
  • II 2D Ex ib IIIC T80°C Db: Zone 21, dust, intrinsically safe, Temp. 80°C

FA 515 Ex may only be used with approved Ex-rated power supplies or safety barriers or galvanic separating elements with max: U2 = 28 V max, I2 = 93 mA max, P2 = 0.65 W max.

Technical Data:
  • Measuring range: -80...20 °Ctd = 4...20 mA
  • Pressure range: -1...500 bar
  • Power supply: 24 VDC (10...30 VDC)
  • Accuracy: ± 1 °C at -20...-20 °Ctd, ± 2 °C at -20...-50 °Ctd, ± 3 °C at -50...-80 °Ctd
  • Output: 4...20 mA in 2-wire technology
  • Protection class: IP 65
  • EMV: according to DIN EN 61326-1
  • Operating temp.: -20...70 °C
  • Storage temp.: -40...80 °C
  • Burden for analogue output: < 500 Ω at 24V
  • Screw-in thread: G 1/2“ stainless steel, optional 5/8” UNF
  • Connection: M12, 4-pin
  • Sensor protection: Sintered filter 50 µm stainless steel
Applications:
  • Air / Compressed air
  • Argon
  • Nitrogen
  • Biogas
  • Natural gas
  • Hydrogen
Product Information:
  • FA 515 Ex pressure dew point meter: Order no. 0699 5515
  • Measuring chamber up to 350 bar: Order no. 0699 3590
  • Measuring chamber made of stainless steel: Order no. 0699 3290
  • Special scaling analogue output to other humidity parameters: % rF, g/m³, mg/m³, ppm V/V, g/kg: Order no. Z699 0514
  • Intrinsically safe power supply, safety barriers: Order no. 0554 3071
See more

Catalog excerpts

Data sheet FA 515 Ex-1

for residual moisture measurement in explosive areas4...20 mA la Intrinsically safe power supply Power supply Contro ler/PLC i=4...20mA ATEX Safe area Hazardous Special features: The FA 515 Ex measures dew point resp. pressure dew point in potentially explosive atmospheres and can be used in many non-aggressive gases. Typical applications: • Air / Compressed air • Argon • Nitrogen • Biogas • Natural gas • Hydrogen • etc... Robust design Pressure-tight up to 500 bar Long-term stable humidity sensor, approved for years 4...20 mA analogue output in 2-wire technologie Further parameters adjustable via software: % RH, g/m3, mg/m3, ppm V/V, g/kg NEW: Higher resolution of the sensor signal due to improved evaluation electronics Approvals: II 2G Ex ib IIC T4 Gb Zone 1, gas, intrinsically safe, Temp. 135°C ATEX II 2D Ex ib NIC T80°C Db Zone 21, dust, intrinsically safe, Temp. 80°C ATEX FA 515 Ex may only be used in connection with approved Ex-rated power supplies or safety barriers or galvanic separating elements with max.: U2 = 28 V max. I2 = 93 mA max. P2 = 0,65 W max. Technical data FA 515 Ex Measuring range: -80...20 °Ctd = 4...20 mA Accuracy: ± 1 °C bei -20...-20 °Ctd technology Protection class: IP 65 Burden for analogue output: < 500 O at 24V Screw-in thread: G 1/2“ stainless steel, Sensor protection: Sintered filter 50 pm stainless steel

 Open the catalog to page 1

All CS Instruments GmbH & Co. KG catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.