Catalog excerpts
Typical applications: • Dew point measurement in the compressed air after desiccant driers/membrane driers • Residual moisture/ dew point measurement in gases like oxygen, nitrogen, argon ... • Residual moisture/ dew point measurement after granulate driers in plastics industry Recommendation: Mounting with standard measuring chamber for compressed air up to 16 bar Advantage: Easy installation via quick coupling Special features: • Measuring range -80...20°Ctd • Extremely long-term stable • Analogue output 4...20 mA • Condensation insensitive • Quick response time • Pressure-tight up to 350 bar (special version) • NEW: Modbus-RTU interface • NEW: Higher resolution of the sensor signal due to improved evaluation electronics • NEW: Sensor diagnosis on site by means of hand-held instrument or CS Service Software Technical data FA 510/515 Measuring -80...20°Ctd range: Accuracy: ± 1°C at 20...-20°Ctd ± 2°C at -20...-50°Ctd ± 3°C at -50...-80°Ctd Pressure range: -1...50 bar special version up to 350 bar Power supply: 24 VDC (16...30 VDC) PC connection: Modbus-RTU interface FA 515: 4...20 mA (2-wire) Burden for analogue output: < 500 O thread: optional: 130 mm Via service software: Choose units: % RH, °Ctd, g/m3, mg/m3,
Open the catalog to page 1Dew point monitoring DS 52 for desiccant driers Consisting of: Special features: • System ready for plug-in: Everything completely wired • No time-consuming studying of the instruction manual • 2 alarm contacts (230 VAC, 3 A) pre-and main alarm freely adjustable - Digital process meter DS 52 (0500 0009) - Standard measuring chamber • 4...20 mA analogue output • Option alarm unit: Buzzer and continuous red light Technical data display DS 52: Dimensions: 118 x 92 x 93 mm ments, height: 13 mm, 5 digits, 2 LED for alarm relay Keypad: 4 keys Alarm outputs: The measuring range of...
Open the catalog to page 2All CS Instruments GmbH & Co. KG catalogs and technical brochures
-
Data sheet FA 510
1 Pages
-
Data sheet - CS Network - EN
3 Pages
-
Data sheet - IAC 500 - EN
1 Pages
-
Data sheet - PTS 500 - EN
1 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
UltraCam LD 500/510
7 Pages
-
Data sheet - VA 570 - EN
5 Pages
-
Data sheet DS 52 Set - EN
1 Pages
-
Data sheet - VA 550 - EN
4 Pages
-
Data sheet - VD 500 - EN
2 Pages
-
Data sheet - DS 500 - EN
4 Pages
-
Data sheet - VX 570 - EN
4 Pages
-
Data sheet - DS 400 - EN
4 Pages
-
Data sheet - VU 570 - EN
3 Pages
-
Data sheet - VA 521 - EN
2 Pages
-
Data sheet - VA 525 - EN
2 Pages
-
Data sheet FA 550 - EN
2 Pages
-
Data sheet - VA 520
4 Pages
-
Data sheet - PI 500
2 Pages
-
Data sheet - DS 400 Set
2 Pages
-
Data sheet FA 500
2 Pages
-
Data sheet - VA 500
2 Pages
-
Data sheet LD 450
2 Pages
-
Data sheet - OILCHECK mobile
6 Pages
-
Data sheet LD 500
8 Pages
-
Data sheet FA 515 Ex
1 Pages
-
Data sheet LD 400
2 Pages
-
Data sheet LD 500
4 Pages
-
Data sheet DP 500
4 Pages
-
Data sheet - VA 570
12 Pages
-
Data sheet - DS 400 mobile
8 Pages
-
Data sheet - DS 500
10 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
Data sheet - DS 500 mobile
8 Pages
-
Data sheet DP 400 mobile
2 Pages
-
Data sheet - PI 500
7 Pages
-
Data sheet - VA 500/520
9 Pages