Data sheet FA 510
1 /1Page

Data sheet FA 510

Data sheet FA 510
1 /1Page

Catalog excerpts

Data sheet FA 510-1

Dew point FA 510/515 - Dew point sensor FA 510/515 for residual moisture measurement in compressed air and gases Typical applications: Special features: • Dew point measurement in the compressed air after adsorption dryer, membrane dryer, refrigeration dryer • Extremely stable in the long term • Analog output 4...20 mA for dew point • Residual moisture/dew point measurement in gases such as oxygen, nitrogen, argon... • Residual moisture/dew point measurement after granulate dryers in the plastics industry • Pressure-tight up to 350 bar (special version) • Quick adaption time • NEW: Modbus-RTU interface • NEW: Higher resolution of sensor signal due to the improved evaluation electronics • NEW: Sensor diagnosis on site with a portable device or CS Service Software Mounting with standard measuring chamber for compressed air up to 16 bar Advantage: Easy installation via quick coupling FA 510 dew point sensor for adsorption dryers -80...20 °Ctd incl. factory certificate, 4…20 mA analogue output (3-wire connection) and Modbus-RTU interface FA 515 dew point sensor for adsorption dryers -80°...20 °Ctd incl. factory certificate, 4…20 mA analogue output (2-wire connection) or Modbus-RTU interface FA 510 dew point sensor for refrigeration dryer -20...50 °Ctd incl. factory certificate, 4…20 mA analogue output (3-wire connection) and Modbus-RTU interface FA 515 dew point sensor for refrigeration dryer -20...50 °Ctd incl. factory certificate, 4…20 mA analogue output (2-wire connection) or Modbus-RTU interface Connection cables: Connection cable for VA/FA series, 5 m Connection cable for VA/FA sensors, 10 m Option for FA 510: Option: analogue output FA 510, special version 2…10 volts Options for FA 510/515: Option: max. pressure FA5xx 350 bar Option: special scaling FA5xx 4…20 mA=__ … __ g/m³, ppm etc. Option: connection thread FA5xx, 5/8" UNF Option: surface condition FA 5xx, free of oil & grease - Pressure dew point [°Ctd.] - Temperature [°C] - rel. humidity [% RH] - abs. humidity [g/m³] - Degree of humidity [g/kg] - Moisture content V/V [ppmV/V] - Partial vapour pressure [hPa] - Atmospheric dew point [°Ctd.atm] TECHNICAL DATA FA 510/515 Measuring range: ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd Pressure range: Power supply: Protection class: Operating temperature: Analogue output: Further accessories: Standard measuring chamber up to 16 bar High pressure measuring chamber up to 350 bar Burden for analogue output: Stainless steel bypass measuring chamber for dew point measurement in gases under pressure Screw-in thread: CS Service Software for dew point sensors incl. PC connection set (Modbus to USB Interface). Calibration and adjustment: Precision calibration at -40 °Ctd or 3 °Ctd incl. ISO certificate Additional calibration point freely selectable

 Open the catalog to page 1

All CS Instruments GmbH & Co. KG catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.