Catalog excerpts
Dew point DS 52 - Dew point monitoring The dew point set is wired ready to plug in at the factory. The alarm values can be set freely. The dew point sensor FA 510 is extremely long-term stable and can be quickly and easily installed and removed under pressure via the screw-on measuring chamber incl. Quick coupling. Option: Alarm unit (Buzzer and continuous red light) Consisting of: Digital process meter DS 52 Special features: • Plug-in system: everything wired and ready • No time-consuming studying of the instruction manual • 2 alarm contacts (250 VAC, 3 A) pre- and main alarm freely adjustable • 4...20 mA analogue output • Option alarm unit: Buzzer and continuous red light Standard measuring chamber Dew point monitoring DS 52 for adsorption dryer consisting of: DS 52 LED process display in the wall housing FA 510 dew point sensor for adsorption dryers -80 °...20 °Ctd incl. factory certificate, 4…20 mA analogue output (3-wire connection) and Modbus-RTU interface Standard measuring chamber up to 16 bar Connection cable for VA/FA series, 5 m Dew point monitoring DS 52 for refrigeration dryers, consisting of: DS 52 LED process display in the wall housing FA 510 dew point sensor for refrigeration dryer -20...50 °Ctd incl. factory certificate, 4…20 mA analogue output (3-wire connection) and Modbus-RTU interface Standard measuring chamber up to 16 bar Connection cable for VA/FA series, 5 m TECHNICAL DATA DISPLAY DS 52 Dimensions: Power supply 24 VDC (instead of 230 VAC) Alarm unit mounted to the wall housing Alarm unit for external mounting with 5 m cable Power supply: 230 VAC, 50/60 Hz; option: 24 VDC or 110 VAC 50/60 Hz 2 x relay output, changeover contact, 250 VAC, max. 3 A Operating temperature: Alarm thresholds: Freely adjustable Analogue output: Power supply 110 VAC (instead of 230 VAC) LED red, 7-segment, height: 13 mm, 5-digit, 2 LED for alarm relay Alarm outputs: Further accessories: Precision calibration at -40 °Ctd incl. ISO certificate Additional calibration point freely selectable
Open the catalog to page 1All CS Instruments GmbH & Co. KG catalogs and technical brochures
-
Data sheet FA 510
1 Pages
-
Data sheet - CS Network - EN
3 Pages
-
Data sheet - IAC 500 - EN
1 Pages
-
Data sheet - PTS 500 - EN
1 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
UltraCam LD 500/510
7 Pages
-
Data sheet - VA 570 - EN
5 Pages
-
Data sheet - VA 550 - EN
4 Pages
-
Data sheet - VD 500 - EN
2 Pages
-
Data sheet - DS 500 - EN
4 Pages
-
Data sheet - VX 570 - EN
4 Pages
-
Data sheet - DS 400 - EN
4 Pages
-
Data sheet - VU 570 - EN
3 Pages
-
Data sheet - VA 521 - EN
2 Pages
-
Data sheet - VA 525 - EN
2 Pages
-
Data sheet FA 550 - EN
2 Pages
-
Data sheet - VA 520
4 Pages
-
Data sheet - PI 500
2 Pages
-
Data sheet - DS 400 Set
2 Pages
-
Data sheet FA 500
2 Pages
-
Data sheet - VA 500
2 Pages
-
Data sheet LD 450
2 Pages
-
Data sheet - OILCHECK mobile
6 Pages
-
Data sheet LD 500
8 Pages
-
Data sheet FA 515 Ex
1 Pages
-
Data sheet LD 400
2 Pages
-
Data sheet LD 500
4 Pages
-
Data sheet DP 500
4 Pages
-
Data sheet FA 510
2 Pages
-
Data sheet - VA 570
12 Pages
-
Data sheet - DS 400 mobile
8 Pages
-
Data sheet - DS 500
10 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
Data sheet - DS 500 mobile
8 Pages
-
Data sheet DP 400 mobile
2 Pages
-
Data sheet - PI 500
7 Pages
-
Data sheet - VA 500/520
9 Pages