Data sheet - DS 500
10Pages

{{requestButtons}}

Catalog excerpts

Data sheet - DS 500 - 1

DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation ■'nstruments. Advantages at a glance: • Clear layout: 7“ colour screen with touch panel... • Versatile: Upto 12 optional sensors can be connected... * Suitable for industrial applications: Metal housing IP 65 or panel mounting * Data available though world wide web: Network-compatible and remote transmission via Webserver • Intelligent: Daily/weekly/monthly reports... • Mathematical function for internal calculations • Totalizer function for analogue signals * ... Saves time and costs during installation From recording ofthe measured data, indication on a big colour screen, alerting, storage up to remote read-out via Webserver... this is all possible with DS 500. By means ofthe CS Soft Basic software alarms can be sent via SMS or e-mail. All measured values, measured curves and threshold exceedings are indicated. The curve progressions from the beginning ofthe measurement can be viewed by an easy slide ofthe finger. Daily/weekly/monthly reports with costs in € and counter reading in m3 for each consumption sensor are completing the sophisticated system concept. The big difference to odinary paperless chart recorders reveals in the easy initiation and in the evaluation ofthe measured data. All sensors are identified directly and powered by DS 500. Everything is matched and tuned. Mathematical function for internal calculations, e.g. the typical figures ofa compressed air plant: • costs in € per generated m3 air • kwh/m3 generated air • consumption of single lines including summation Totalizer function for analogue signals (e.g. 0/4...20 mA, 0...10 V). In case of third-party sensorswhich e.g. only give a 4...20 mA signal for the actual flow in m3/h a total counter reading in m3 can be generated by means ofthe totalizer function. No time consuming studying ofthe instruction manual... this saves time. Internal voltage supply ofall sensors, no wiring of external mains units ... this saves additional costs.

Open the catalog to page 1
Data sheet - DS 500 - 2

All important information at a glanceMeasured values, statistics, curves with the 7” colour screen touch panel Real time measured values All measured values can be seen at a glance. Threshold exceeding are indicated in red colour. A„measuring site name" can be allocated to each sensor. Graphic display This display replaces the former evaluation of ordinary paper chart recorders and offers lots of advantages. The time axis can be moved by a finger slide. The „zoom function by finger movement" which enables an analysis of peakvalues is unique. Real time measured values and graph Additionally...

Open the catalog to page 2
Data sheet - DS 500 - 3

DS 500Intelligent chart recorder for compressed air and gases Versatile: Upto12 sensors, incl. all CS sensors (consumption, dew point, pressure, current, KTY, PT 100, PT 1000) are identified automatically by DS 500. Optional analogue sensors (0/4...20mA, 0...1/10/30V, pulse) can be configured easily and quickly. Digital sensors can be connected via RS 485, Modbus RTU and SDI. Flexible: Network-compatible and worldwide remote data transmission via Ethernet, integrated Webserver. Alarm relay/fault indication: Up to 32 threshold values can be configured freely and allocated to 4 different...

Open the catalog to page 3
Data sheet - DS 500 - 4

Flow sensors for compressed air and gases Extremely long-term stable Quick adaption time Large measuring range (-80° to +20oCtd) For all driers: Desiccant driers, membrane driers, refrigeration driers Large selection of pressure sensorswith different measuring rangesfor each measuring purpose ♦ Quick installation under ressure by quick coupling ♦ Easy installation under pressure via the standard measuring chamber with quick coupling ♦ Pressure sensors 0-10/16/40/100/250/400/600 bar overpressure ♦ Pressure sensors -1 - +15 bar (under-/overpressure) ♦ Differential pressure 1.5 mbar up to 4.2...

Open the catalog to page 4
Data sheet - DS 500 - 5

Technical data DS 500 Dimensions ofhousing: Connections: Version panel mounting: Weight: Material: Sensor inputs: Power supply for sensors: Interfaces: Outputs: Memory card: Power supply: Colour screen: Accuracy: Operating temperature: Storage temperature: Optionally: Optionally: Optionally: 280 x 170 x90 mm, IP 65 18 x PG 12 for sensors and supply, alarm relays 1xRJ45 Ethernet connection Cutout panel 250 x 156 mm 7.3 Kg Die cast metal, front screen polyester • 4/8/12 sensor inputs for analogue and digital sensors freely allocatable. See options • Digital CS sensors for dew point and...

Open the catalog to page 5
Data sheet - DS 500 - 6

Suitable probes from the product range: Order No. VA 500 flow sensor in basic version: Standard (92.7 m/s), sensor length 220 mm, without display Options for VA 500: (see page 81) Flow meter VA 520 with Flow meter VA 520 with Flow meter VA 520 with Flow meter VA 520 with Flow meter VA 520 with Flow meter VA 520 with Flow meter VA 520 with ntegrated measuring section, (R 1/4“ DN 8) ntegrated measuring section, (R 1/2“ DN 15) ntegrated measuring section, (R 3/4“ DN 20) ntegrated measuring section, (R 1“ DN 25) ntegrated measuring section, (R 1 1/4“ DN 32) ntegrated measuring section, (R 1...

Open the catalog to page 6
Data sheet - DS 500 - 7

CS PM 210 Current/effective power meter for panel mounting Measures voltage, currentand calculates: All measured data are transferred digitally (Modbus) to DS 500 and can be recorded there. Active power [kW] Apparent power [kVA] Reactive power [kVar] Active energy [kWh] Parameters: Voltage (Volt) Current (Ampere) Cos phi Active power (kW) Apparent power (kVA) Reactive power (kVar) Active energy (kWh) Supply frequency (Hz) All parameters are transferred digitally to DS 500 Accuracy ± 0,5% of 1 to6 A Accuracy active IEC 62053-21 Class 1 energy: Interfaces: RS 485 (Modbus...

Open the catalog to page 7
Data sheet - DS 500 - 8

Software CS Soft Basic - evaluation of measured data for single computers The measured data stored in the data logger integrated in DS 500 can be read-outvia USB stick. If DS 500 has the optional Ethernet interface the measured data can also be read-out over big distances via the computer network Graphic evaluation All measurement curves are indicated in different colours. All necessary functions like free zoom, selection/deselection of single measured curves, free selection oftime periods, scaling ofthe axis, selection of colours and so on are integrated: This view can be stored as a pdf...

Open the catalog to page 8

All CS Instruments GmbH & Co. KG catalogs and technical brochures