Data sheet - DS 500 mobile
8Pages

{{requestButtons}}

Catalog excerpts

Data sheet - DS 500 mobile - 1

DS 500 mobile Intelligent mobile chart recorderThe intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - flow measurement - leakage calculation at compressed air systems Your advantages at a glance Easy and clear layout: Very easy operation via 7“ color display with touch panel Versatile: Upto 12 sensors/meters connectable also third-party sensors/meters including power supply Reliable: Stores all measured values on a memory card, easy reading-outvia USB stickpossible Intelligent energy analysis: Daily/weekly/monthly evaluations mathematic function for internal calculations, e.g. the typical key data ofa compressed air plant: - costs in € per generated m3 air - kWh/m3 generated air - flow of single lines including summation

Open the catalog to page 1
Data sheet - DS 500 mobile - 2

Technical Data DS 500 mobile - mesurement of upto12 compressorsTechnical data DS 500 mobile Casedimensions: 360 x270 x 150 mm Connections: 4/8/12 sensors and supply, Material: diecast, front foil polyester, ABS Sensor inputs: • 4/8/12 sensor inputs for analogue and digital sensors; freely alloca- table. See options • Digital CS sensors for dew point and flow with SDI interface FA/VA series, digital third-party sensors RS 485 / Modbus RTU. • Analogue CS Sensors for pressure, temperature, clamp-on ammeters preconfigured • Analogue third-party sensors 0/4...20 mA, 0...1/10/30V,...

Open the catalog to page 2
Data sheet - DS 500 mobile - 3

Intelligent mobile chart recorder DS 500 mobile energy analysis to DIN EN ISO 50001 Ifwe talk about operational costs ofcompressed air plants we are actually talking about the energy cost as they make up about 70 to 80 % ofthe total costs ofa compressed air plant. Depending on the size of the plant this means considerable operating costs. Even in smaller plants this may quickly add up to 10.000 to 20.000 € per year. This is an amount which can be considerably reduced - even in the case of well operated and maintained plants. Does this also apply to your compressed air plant? Which actual...

Open the catalog to page 3
Data sheet - DS 500 mobile - 4

Flow sensors for compressed air and gases Pressure sensors Temperature sensors Clamp-on ammeters Heat meters-/ water and gas meters Current/effective power meters Current/effective power meters By means of the mobile chart recorder DS 500 mobile, all measuring data of a compressor station can be recorded, indicated and evaluated. At 12 freely assignable sensor inputs all our sensors can be connected as well as any optional third-party sensors and meters with the following signal outputs: 4-20 mA, 0-20 mA 10-1 V/0-10V/ 0-30 VIPtlOO (2- or 3-wire), Pt 1000 (2- or 3-wire), KTY I pulse outputs...

Open the catalog to page 4
Data sheet - DS 500 mobile - 5

Step 1: The measurement It is a special advantage that up to 12 compressors can be measured with one DS 500 mobile at the same time. {{Cable connection or GSM module Pressure sensor Step 2: 1 Compressor analysis ( (current / power measurement) The energy consumption ofevery single compressor is measured by means ofa clamp-on ammeter. The produced compressed air quantity is calculated by the software on the basis of the performance data ofthe compressor which have to be calculated. The following parameters are calculated additionally. Energy consumption in kWh, load-, unload-, stop time,...

Open the catalog to page 5
Data sheet - DS 500 mobile - 6

Step 3: Evaluation at the PC with graphics and statistics 3.1 Entry of necessary parameters Specific data have to be entered before the analysis is carried out: • Selection of compressor type (load/idle resp. variable speed drive controlled) • aswell as entry of the performance data according to data sheet • Period of measurement • Costs in € for 1 kWh 3.2 Graphic evaluation with day view and week view Everything at a glance: The user gets a day and a week view of all stored measured data with his company logo (can be easily integrated) at the touch of a button. By means of the zoom and the...

Open the catalog to page 6
Data sheet - DS 500 mobile - 7

Suitable sensors for DS 500 mobile & DS 400 mobile Flow sensors VA 500: Flow meterVA520, 0,8... 90 l/min, (R 1/4“ DN 8) Flow meter VA 520, 0,2... 90 m3/h, (R 1/2“ DN 15) Flow meter VA 520, 0,3... 170 m3/h, (R 3/4“ DN 20) Flow meterVA520, 0,5... 290 m3/h, (R 1“ DN 25) Flow meter VA 520, 0,7... 480 m3/h, (R 1 1/4“ DN 32) Flow meter VA 520, 1,0... 550 m3/h, (R 1 1/2“ DN 40) Flow meterVA520, 2,0... 900 m3/h, (R 2“ DN 50) Dew point sensors: FA 510 dew point sensor for mobile instruments, -80...+20°Ctd, incl. mobile measuring chamber, 5 m cable and perforated cap FA510dew point sensorformobile...

Open the catalog to page 7
Data sheet - DS 500 mobile - 8

Suitable sensors for DS 500 mobile & DS 400 mobile Temperature sensors: Bendable temperature probe PT 100 (2-wire) class A, length: 300 mm, d=3 mm, -70°C to +500°C, connection cable PFA, 2 mwith ODU-plug (8 pole) to mobile instruments Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4...20 mA= -50°C...+500°C (2-wire) Cross-band surface temperature probe, thermocouple Type K, with integrated transducer 4...20 mA= 0°C...+180°C, 2 m connection calbe (PVC) with ODU-plug (8-pole) to mobile instruments Temperature probe PT 100 class A (4-wire) with...

Open the catalog to page 8