Chart recorder DS 500 - Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation Advantages at a glance: • Clear layout: 7" colour screen with touch panel... • Versatile:Up to 12 optional sensors can be connected • Suitable for industrial applications: Metal housing IP 65 or panel mounting... • Data available through world wide web: Network-compatible and remote transmission via webserver • Mathematical function: for internal calculations • Totaliser function: for analogueue signals • ...saves time and costs during installation DS 500 - the intelligent chart recorder of the next generation Recording of the measured data, indication on a big colour screen, alerting, storage, not to mention remote read-out via webserver... this is all possible with DS 500. All measured values, measurement curves and threshold value exceedances are indicated. The curve progressions from the beginning of the measurement can be viewed by an easy slide of the finger. The big difference to ordinary paperless chart recorders reveals in the easy initiation and in the evaluation of the measured data. All sensors are identified directly and powered by DS 500. Everything is matched and tuned. Mathematical function for internal calculations, e.g. the typical figures of a compressed air system: • consumption of single lines including summation Totaliser function for analogueue signals (e.g. 0/4…20 mA, 0…10 V). In case of third-party sensors which e.g. only give a 4...20 mA signal for the actual flow in m³/h, a total counter reading in m³ can be generated by means of the totaliser function. No time consuming studying of the instruction manual... this saves time. Internal voltage supply of all sensors, no wiring of external mains units ... this saves additional costs.
Open the catalog to page 1Chart recorder Flow meters for compressed air and gases • Installation and removal under pressure via standard 1/2" ball valve A safety ring prevents the uncontrolled ejection in case of installation/removal under pressure Usable for different gases: Compressed air, nitrogen, argon, CO2, oxygen… Pressure sensors Large selection of temperature sensors e.g. for measurement of the ambient temperature or gas temperature For all dryers: (Adsorption dryers, membrane dryers and refrigeration dryers) Easy installation under pressure via the measuring chamber with quick coupling Monitoring of...
Open the catalog to page 2Chart recorder Measured values, statistics, curves with the 7" colour screen with touch panel Actual measured values All measured values can be seen at a glance. Threshold value exceedances are indicated in red color. A „measuring site name“ can be allocated to each sensor. Graphic display This display replaces the former evaluation of ordinary paper chart recorders and offers lots of advantages. The time axis can be moved by a finger slide. The „zoom function by finger movement“ which enables an analysis of peak values is unique. Actual measured values and graphic Additionally to the...
Open the catalog to page 3Chart recorder Technical data of the DS 500 TECHNICAL DATA DS 500 Dimensions of housing: Version panel mounting: Die cast metal, front screen polyester Sensor inputs: Voltage supply for sensor: 24 VDC, max. 130 mA per sensor, integrated mains unit max. 24 VDC, 25 W. In case of version 8/12 sensor inputs, 2 integrated mains units each max. 24 VDC, 25 W. USB stick, Ethernet / RS 485 Modbus-RTU / TCP, SDI other bus systems on request, webserver optional Memory card: Memory size 16 GB Micro SD card Power supply: Colour screen: 7" touch panel TFT transmissive, graphics, curves, statistics...
Open the catalog to page 4All CS Instruments GmbH & Co. KG catalogs and technical brochures
-
Data sheet FA 510
1 Pages
-
Data sheet - CS Network - EN
3 Pages
-
Data sheet - IAC 500 - EN
1 Pages
-
Data sheet - PTS 500 - EN
1 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
UltraCam LD 500/510
7 Pages
-
Data sheet - VA 570 - EN
5 Pages
-
Data sheet DS 52 Set - EN
1 Pages
-
Data sheet - VA 550 - EN
4 Pages
-
Data sheet - VD 500 - EN
2 Pages
-
Data sheet - VX 570 - EN
4 Pages
-
Data sheet - DS 400 - EN
4 Pages
-
Data sheet - VU 570 - EN
3 Pages
-
Data sheet - VA 521 - EN
2 Pages
-
Data sheet - VA 525 - EN
2 Pages
-
Data sheet FA 550 - EN
2 Pages
-
Data sheet - VA 520
4 Pages
-
Data sheet - PI 500
2 Pages
-
Data sheet - DS 400 Set
2 Pages
-
Data sheet FA 500
2 Pages
-
Data sheet - VA 500
2 Pages
-
Data sheet LD 450
2 Pages
-
Data sheet - OILCHECK mobile
6 Pages
-
Data sheet LD 500
8 Pages
-
Data sheet FA 515 Ex
1 Pages
-
Data sheet LD 400
2 Pages
-
Data sheet LD 500
4 Pages
-
Data sheet DP 500
4 Pages
-
Data sheet FA 510
2 Pages
-
Data sheet - VA 570
12 Pages
-
Data sheet - DS 400 mobile
8 Pages
-
Data sheet - DS 500
10 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
Data sheet - DS 500 mobile
8 Pages
-
Data sheet DP 400 mobile
2 Pages
-
Data sheet - PI 500
7 Pages
-
Data sheet - VA 500/520
9 Pages