Catalog excerpts
The new instruments DP 500/ DP 510 are the ideal portable service instruments for dew point measurement for all types of driers down to -80°Ctd dew point. The 3.5“ graphic display with touch screen makes the operation very easy. The graphic indication of colored measuring curves is unique. Ideal for measurement of the current dew point and for graphic indication of the dew point curve/ the switching behavior of the dryer over a longer period of time. Up to 100 million measured values can be stored with date and measuring site name. The measured data can be transferred to the computer via USB stick. The data can be evaluated comfortably by means of the software CS Soft Basic. Measured data and service reports can be issued easily and quickly. DP 510 additionally disposes of one further freely assignable sensor input. Apart from the internal dew point measurement one further optional sensor can be connected like for example: • Pressure sensors • Flow sensors, VA 500/520 2nd freely assignable sensor input for third-party sensors (only DP 510) • Temperature sensors Pt 100, 4...20mA • Further dew point sensors • Effective power meters • Optional third-party sensors with the following signals: 0...1/10 V, 0/4...20 mA, Pt 100, Pt 1000, pulse, Modbus Special features: • Precise dew point measurement down to -80°Ctd • Quick response time • 3.5“ graphic display / easy operation via touch screen • Integrated data logger for storage of the measured values • USB interface for reading out via USB stick • Calculates all necessary moisture parameters like g/m3, mg/m3, ppm V/V, g/kg, °Ctdatm • 2nd freely assignable sensor input for third-party sensors (only DP 510) • International: Up to 8 languages selectable • Compressed air: Examination of refrigeration, membrane, desiccant driers • Technical gases: Residual moisture measurement in gases like N2, O2 and so on • Plastics industry: Examination of granulate driers • Medical compressed air/breathing air
Open the catalog to page 1Dew point Measurement curves are indicated graphically and thus the user can see at a glance the behavior of the dryer since the start of the measurement. 6.540 bar All physical parameters of moisture measurement are calculated automatically. In case of DP 510 the measured values of the third-party sensor are indicated additionally. Ideal for service technicians -everything in one case Logger settings Logger stopped timed Start timed Stop Remaining logger capacity ~ 999S days It is possible to store up to 100 million measured values. Each measurement can be stored with a comment, e.g....
Open the catalog to page 2The stored measured data can be easily transferred to the computer via a USB stick or via a USB cable. The time periods are freely selectable or you just read out the whole memory. The data can be evaluated by means of the software CS Soft Basic in table and in graphic form. World debut screen-shot key Ideal for documentation of the measured values/measurement curves on site. Colored measurement curves can be sent by e-mail or integrated into a service report. By means of the screen-shot key the ..current screen" can be stored as an image file and printed out at the computer or edited...
Open the catalog to page 3Oat view Statlslicjr'rafijlar newj^Tabular view rew date Graphic evaluation All measurement curves are indicated in terms of color. All necessary functions such as zoom, selection/deselection of single measurement curves, freely selectable time periods, scaling of the axis, selection of colors and so on are integrated: This view can be stored as a pdf file and sent by e-mail. Different data can be consolidated to a common file. Table view All measuring points are listed with exact time interval. The desired measuring channels with measuring site name can be selected via the diagram...
Open the catalog to page 4All CS Instruments GmbH & Co. KG catalogs and technical brochures
-
Data sheet FA 510
1 Pages
-
Data sheet - CS Network - EN
3 Pages
-
Data sheet - IAC 500 - EN
1 Pages
-
Data sheet - PTS 500 - EN
1 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
UltraCam LD 500/510
7 Pages
-
Data sheet - VA 570 - EN
5 Pages
-
Data sheet DS 52 Set - EN
1 Pages
-
Data sheet - VA 550 - EN
4 Pages
-
Data sheet - VD 500 - EN
2 Pages
-
Data sheet - DS 500 - EN
4 Pages
-
Data sheet - VX 570 - EN
4 Pages
-
Data sheet - DS 400 - EN
4 Pages
-
Data sheet - VU 570 - EN
3 Pages
-
Data sheet - VA 521 - EN
2 Pages
-
Data sheet - VA 525 - EN
2 Pages
-
Data sheet FA 550 - EN
2 Pages
-
Data sheet - VA 520
4 Pages
-
Data sheet - PI 500
2 Pages
-
Data sheet - DS 400 Set
2 Pages
-
Data sheet FA 500
2 Pages
-
Data sheet - VA 500
2 Pages
-
Data sheet LD 450
2 Pages
-
Data sheet - OILCHECK mobile
6 Pages
-
Data sheet LD 500
8 Pages
-
Data sheet FA 515 Ex
1 Pages
-
Data sheet LD 400
2 Pages
-
Data sheet LD 500
4 Pages
-
Data sheet FA 510
2 Pages
-
Data sheet - VA 570
12 Pages
-
Data sheet - DS 400 mobile
8 Pages
-
Data sheet - DS 500
10 Pages
-
Data sheet - PC 400 mobile
6 Pages
-
Data sheet - DS 500 mobile
8 Pages
-
Data sheet DP 400 mobile
2 Pages
-
Data sheet - PI 500
7 Pages
-
Data sheet - VA 500/520
9 Pages